• Title/Summary/Keyword: gas transfer

Search Result 1,728, Processing Time 0.022 seconds

Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers (경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (I) (수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향)

  • Kim, Byeong-Ju;Lee, Chan-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.489-498
    • /
    • 1998
  • Among the heat/mass exchange units composing an absorption system, the absorber, where the refrigerant vapor is absorbed into the liquid solution is the one least understood. In the present study, the effects of non-absorbable gas on the absorption process of aqueous lithium bromide solution falling film inside a vertical tube were experimentally investigated. In the range of film Reynolds number of 30 ~ 195, heat and mass transfer characteristics were investigated as a function of non-absorbable gas volumetric concentration, 0.2 ~ 20%. An increase of non-absorbable gas volumetric concentration degraded the mass transfer rate dramatically in the absorption process. The reduction of mass transfer rate was significant for the addition of small amount of non-absorbable gas to the pure vapor. At film Reynolds number of 130, an increase of non-absorbable gas concentration from 0.2 to 6.0% resulted in the decrease of mass transfer rate by 36% and 20% of non-absorbable gas by 59%. However the decrease of film Nusselt number with the increase of volumetric concentration of non absorbable gas was relatively smaller than the decrease of Sherwood number. Critical film Reynolds number was identified to exist for the maximum heat and mass transfer regardless of the volumetric concentration of non-absorbable gases.

Augmentation of Radiative Heat Transfer in an Infinite Cylindrical Pipe Enclosing a Participating Gas (참여기체를 가진 무한 원형관 계의 복사 열전달 증진)

  • 변기홍
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1955-1962
    • /
    • 1992
  • The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature, The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the range of values studied for a real gas, if the system diameter is larger than about 0.1m the augmentation parameter increases up to about 1.2 as the system diameter increases. The augmentation parameter have a maximum value at a certain diameter ratio. The augmentation parameters decreases as the emittance of the installed wall decreases. If the gas temperature is higher than about 1273 k, the augmentation parameter decreases as the gas temperature increases.

A CFD ANALYSIS ON THE INFLUENCE OF OPERATING CONDITIONS AND EJECTOR CONFIGURATION ON THE HYDRODYNAMICS AND MASS TRANSFER CHARACTERISTICS OF GAS-LIQUID EJECTOR

  • Utomo, Tony;Jin, Zen-Hua;Yi, Chung-Seub;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2817-2822
    • /
    • 2007
  • The purpose of this paper is to study the influence of operating condition and ejector geometries on the hydrodynamics and on the mass transfer characteristic of ejector. The CFD results were validated with available experimental data. Flow field analyses and predictions of ejector performance were also carried out. Variation on the operating conditions was made by varying the gas-liquid flow rate ratio in the range of 0.2 to 1.2. The ejector configuration was also varied on the length to diameter ratio of mixing tube ($L_M/D_M$) in the range of 4 to 10. CFD studies show that at $L_M/D_M$ 5.5, the volumetric mass transfer coefficient increases with respect to gas flow rates. Meanwhile, at $L_M/D_M$ 4, the plot of volumetric mass transfer coefficient to gas-liquid flow rates ratio reach maximum at gas-liquid flow rates ratio of 0.6. This study also shows that volumetric mass transfer coefficient decrease with respect to the increase of mixing tube length.

  • PDF

Performance Analysis with Change in Design Parameters of $CO_2$ Heat Pump Gas Cooler ($CO_2$ 히트펌프 가스쿨러의 설계변수 변화에 따른 성능해석)

  • Chang, Young-Soo;Kim, Min-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.639-644
    • /
    • 2006
  • The outlet temperature of gas cooler has a great effect on the efficiency of carbon dioxide heat pump system. In order to obtain a small approach temperature difference at gas cooler, near-counter flow type heat exchanger has been proposed, and larger heat transfer area is demanded. The optimum design of gas cooler involving the analysis of trade-offs between heat transfer performance and cost is desirable. In this study, the effects of geometric parameters, such as the circuit arrangement, tube diameter, transverse tube spacing, longitudinal tube spacing and the number of tube rows and fin spacing on the performance of heat transfer were investigated using the developed model. This study suggested various simulation results for optimum designs of gas cooler.

  • PDF

A study on effect of heat transfer of condensation including noncondensable gas over a flat plate (불응축가스가 평판위 응축열전달에 미치는 영향에 관한 연구)

  • 양대일;정형호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.25-30
    • /
    • 2000
  • In present paper, mass transfer over a flat plate with film condensation including noncondesable gas is analyzed with the help of similarity methods. Couette flow was assumed in liquid film and boundary-layer approximation was used in the ambient flow. Governing equations were transformed into the ordinary differential equtions by the similarity methods. Runge-Kutta and shooting method were used in order to fine the effect of mass transfer on the velocity and concentrations at the liquid-vapor interface.

  • PDF

Numerical Analysis of Combustion and Heat Transfer of Domestic Gas Boiler Equipped with 2-stage Heat Exchanger (수치해법을 이용한 2단 열교환기 장착 가정용 보일러 연소실의 연소 및 열전달 특성 해석)

  • Kang, Seung-Kyu;Choi, Kyoung-Suhk;Kwon, Jeong-Rack
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.1-6
    • /
    • 2010
  • In this work, a numerical investigation is performed for the combustion chamber of domestic gas boiler with 1-stage and 2-stage heat exchangers. The fluid flow and heat transfer performance is simulated with a structure change of heat exchanger. The numerical solution shows that the heat transfer of the 2-stage heat exchanger is about 24% higher than that of the 1-stage heat exchanger, while the pressure loss of the 2-stage heat exchanger increases. The temperature of combustion chamber with 2-stage heat exchanger is lower than that of 1-stage. This effect reduces thermal NOx with decrease of high temperature staying time of the combustion gas.

Condensation Heat Transfer for the R-11 Superheated Vapor with and without Noncondensable Gas (R-11의 응축열전달에 미치는 부응축가스 및 과열의 영향)

  • CHO Kwon-Ok;KUM Jong-Soo;OH HOO-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.85-93
    • /
    • 1985
  • An experimental investigation on condensing heat transfer for the Refrigerant-11 superheated vapor during condensation on the 40 mm O.D by 75 mm long horizontal tube is carried out under the various conditions of air contents as noncondensable gas, condensing pressure, and coolant temperature. The data span a refrigerant flow range from 23 to 63 kg/h and weight fractions of noncondensable gas range from 0 to $15\%$. The comparisons are made using data obtained by the authors and further data obtained from other sources. The characteristics of the condensing heat transfer of refrigerant superheated vapor with and without noncondensable gas flowing horizontally are revealed experimentally, and on the basis of the data obtained, correlations for predicting heat transfer coefficient during condensation on the tube are proposed.

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop Characteristics during Supercritical Process of Carbon Dioxide in a Horizontal Tube (수평관 내에서 이산화탄소 초임계 가스냉각 과정의 열전달 및 압력강하 특성에 관한 실험적 연구)

  • 최이철;강병하;김석현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.414-420
    • /
    • 2004
  • The heat transfer and pressure drop characteristics associated with the gas cooling of the supercritical carbon dioxide in a horizontal tube have been investigated experimentally. This problem is of particular interest in the design of a gas cooler of cooling systems using $CO_2$refrigerant. The test section is consisted of 6 series of 455 mm in length, 4.15 mm ID copper tube, respectively. The effects of the inlet temperature, pressure and mass flow rate on the heat transfer and pressure drop of $CO_2$in a horizontal tube is studied in detail. The heat transfer coefficient of $CO_2$is varied by temperature, inlet pressure, and mass flow rate of $CO_2$. This has maximum value at near the pseudocritical temperature. The pressure drop is changed by inlet pressure and mass flow rate of $CO_2$. The results have been compared with those of previous work. The heat transfer correlation at the supercritical gas cooling process is also suggested.