• 제목/요약/키워드: gas transfer

검색결과 1,728건 처리시간 0.026초

막 두께 및 유동 조건에 따른 PEMFC 용 Gas to Gas 막가습기의 열/물 교환 특성 (Characteristics of Heat and Water Transfer in Gas to Gas Membrane Humidifiers with Various Membrane Thickness and Flow Condition)

  • 강경태;황준영;김희수;박명석;박정규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.429-432
    • /
    • 2006
  • Characteristics of heat and water transfer in gas-to-gas membrane humidifiers have been experimentally investigated for various humidity rod flow rates of gas and for different thickness of Nafion membrane. The results emphasizes the importance of flow velocity for both water and heat transfer. Also, the effect of membrane thickness has been revealed to be significant to water transfer especially for unsaturated flows, while the significance of membrane thickness is minimal to heat transfer.

  • PDF

Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

  • Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • 제53권3호
    • /
    • pp.315-320
    • /
    • 2015
  • Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient ($k_La$), interfacial area (a) and liquid side true mass transfer coefficient ($k_L$) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of $O_2$ and chemical absorption of $CO_2$ in the column. The values of $k_La$ and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of $k_L$ increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases.

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

혈관 내 폐 보조장치에서의 산소전달속도 예측에 관한 연구 (A Study of Prediction of Gas Transfer rate in Intravascular Lung Assist Device)

  • 김기범;나도춘;김성종;정인수;정경락;권대규
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.18-25
    • /
    • 2004
  • 본 연구의 목적은 정맥 내 폐 보조장치 설계에 있어서 기체전달을 예측하기 위하여 혈관 내 폐 보조장치를 정맥 내에 삽입하기 전, 여러 가지 설계조건에서 실험적 모델링을 통하여 예측식을 찾고자 시도하였다. 실험결과 중공사 충진율의 함수에 따라 기체전달을 예측할 수 있었다. 실험에 의하여 얻어진 기체전달은 예측식에 의한 기체전달과 유사하여, 식에 대한 신뢰성을 얻을 수 있었다. 그러므로, 중공사의 충진율의 함수에 따라 기체전달을 예측할 수 있으며, 혈관 내 폐 보조장치의 기체전달을 예측하는데 매우 유용하였다.

Narrow Baud Radiative Solutions within a Cubical Enclosure Filled with Real Gas Mixtures

  • Kim, Tae-Kuk;Park, Won-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제16권6호
    • /
    • pp.861-869
    • /
    • 2002
  • Radiative transfer by nongray gas mixtures with nonuniform concentration and temperature profiles is studied by using the statistical narrow-band model and the ray-tracing method with the sufficiently accurate T$\_$60/ quadrature set. Transmittances through the nonhomogeneous gas mixtures are calculated by using the Curtis-Godson approximation. Three different cases with different temperature and concentration profiles are considered profiles are considered to obtain benchmark solutions for the radiative transfer by nongray gas mixtures. The solutions obtained from this study are verified and found to be very well matched with the previous solutions for uniform gas mixtures. The results presented in this paper can be used as benchmark solutions in developing various solution methods for radiative transfer by nongray gas mixtures.

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

기체 고체 반응기 모형의 응용: 환원로 반응 모형 고찰 (The Application of Gas-Solid Reactor Model: Consideration of Reduction reaction model)

  • 엄민제;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.79-82
    • /
    • 2012
  • The gas-solid reactor, such as rotary kiln, sintering bed, incinerator and CFB boiler, is the one of most widely used industrial reactors for contacting gases and solids. the gas-solid reactor are mainly used for drying, calcining and reducing solid materials. In the gas-solid reactor, heat is supplied to the outside of the wall or inside of the reactor. The heat transfer in gas-solid reactor encompasses all the modes of transport mechanisms, that is, conduction, convection and radiation. The chemical reactions occurring in the bed are driven by energy supplied by the heat transfer. This paper deal with the effect of heat transfer and chemical reaction in the gas-solid reactor.

  • PDF

기포탑에서 점성수용액의 가스전달에 관한 연구 (A Study on Gas Transfer of Viscous Aqueous Solutions in a Bubble Column)

  • 최일곤;김상렬
    • 한국안전학회지
    • /
    • 제9권3호
    • /
    • pp.67-73
    • /
    • 1994
  • The gas holdup and volumeteric liquid phase mass transfer coefficient with the variation of the concentration of CMC aqueous solution, gas velocity, diameter and area of the draught tube were investigated. As the results of the experiments, the gas holdup and volumetric liquid phase mass transfer coefficient decreased with decreasing the concentration of CMC aqueous solution, increased with increasing the gas velocity and increased with increasing the circulated area ratio of the draught tube.

  • PDF

대기오염제어를 위한 생물살수여과법에서 물질전달 Model과 계수에 관한 연구 (Mass Transfer Model and Coefficient on Biotrickling Filtration for Air Pollution Control)

  • 원양수;조완근
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.489-495
    • /
    • 2015
  • 대기오염물질처리를 위한 생물살수여과법에서 물질전달현상을 이해하기 위한 선행 실험결과를 기초로 각각의 운전조건에서 기체/액체(살수액), 기체/고체(미생물)와 액체/고체에서의 model을 이용하여 물질전달계수를 평가하였다. 생물살수여과법에서 기/액에서는 정상상태물질수지, 그리고 액/고와 기/고에서는 동적물질수지를 이용하여 물질전달 model을 확립하고 그 결과를 고찰하였다. 물질전달 model은 여과탑을 일정크기 구획하여, 각 구획에서 동적 물질수지식을 수치해석 전산코드를 이용해 계산하였다. 동적물질수지식을 이용하여 계산된 결과는 실험결과와 비교하여 생물살수여과법에서 기/액, 기/고, 액/고 각상간의 물질전달계수($K_La$)를 산정하였다. 본 연구에서는 대기오염제어를 위한 생물살수여과법에서 물질전달계수를 결정하기 위한 실험방법개발과 model을 이용하여 물질전달현상을 고찰하였다.

초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석 (Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.