A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

Accelerated life test of SF_6 gas load break switch for overhead line (가공용 가스절연부하개폐기 가속수명시험)

  • Park Seung Jae;Heo Jong Chul;Kim Maeng Hyun;Koh Heui Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF

Study of Multichannel Pseudo-spark Switch for High-voltage and High-current (고전압 대전류 Multichannel Pseudo-spark 스위치 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1859-1861
    • /
    • 2002
  • This paper attempts to discuss the pseudo-spark which is developed for high voltage and high current. The pseudo-spark switch is on the basic of the Paschen's law. The pseudo-spark switch fabricates the glass chamber. The pseudo-spark switch consists of hollow cathode, hollow anode, and trigger. The pseudo-spark switch is operated at the voltage of 20 kV and the pressure range of $20{\sim}80$ mtorr with He-gas. The switching current of the pseudo-spark switch was measured as 65 kA, and the duration of the pulse was about 100 ${\mu}s$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

Development of Pulsed Power System for 500kA Current Generation

  • Lee, Hyeong-Ho;Seo, Kil-Soo;Kim, Yeong-Bae;Cho, Kook-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.23-28
    • /
    • 1999
  • The manufactured pulsed power system with 500kA current is described in this paper. The capacitor bank, control cabinent, dec charging unit, closing switch and dumping box, cable system etc. employed with the system components are described. Especially the development of the inverse pinch switch controlled by gas puffing enabled the generation of the very high voltage and current.

  • PDF

A study on the Application of a Monitoring System for Gas Insulaterd Switchgear (가스절연개폐장치용 감시시스템 적용에 관한 연구)

  • Kim, Jeong-Bae;Kim, Min-Su;Song, Won-Pyo;Kim, Deok-Su;Jeon, Chan-Seok;Gil, Gyeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.22-30
    • /
    • 2002
  • ln this paper, it was reported the developed results of the monitoring unit for 72.5kY GIS which it is one part of the monitoring system for the substation that Korea Railway Company is promoting. In order to monitor the operational status of GIS, four parameters were chosen: the number of times of the circuit breaker switching, tightness of the gas-sealed units (circuit breaker / disconnecting switch / earthing switch), the number of times of the lightning arrestor operating and the leakage current of the lighting arrester. We constructed the monitoring system that can be judged the operating condition of the GIS from the signal of the suitable sensor for the purpose. Therefore, it is possible to on line monitoring for the condition of the GlS without efforts of the Periodic inspection.

Interface design Between AMR and DAS (AMR과 DAS의 인터페이스 구현)

  • Jung, Jum-Soo;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.126-133
    • /
    • 2008
  • Computer and communication of based IT technology use to das that remote control, monitoring, measuring automatic gas switch, recloser located far about $20{\sim}30[km]$. For increasing efficiency billing, metering of high voltage customer use to amr system. If between das and amr interface operate when generated fault in high voltage electric equipment of customer part, amr system serve to das quickly in fault information data, correct fault location.

The Functions and Characteristics of Distribution Automation System Components (국산 배전자동화시스템 구성설비의 보유기능 및 특성)

  • Ha, B.N.;Park, S.M.;Jang, J.T.;Choi, T.I.;Kim, H.Y.;Oh, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

A Study on the Lightning Protection and Earthing Supplement for 154kV Switch yard of Hapchon Hydro-Power Station (합천수력 154kV 옥외변전소 낙뢰대책 및 접지보강 연구)

  • NamKung, Hyuk;Jeon, Kyu-Nam;Ock, Gwang-Seok;Choi, Hyong-Chul;Lee, Nam-Hyong;Jang, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.83_84
    • /
    • 2009
  • The Gas Circuit Breaker for the Main Transformer in switch yard at the 1st Hapcheon hydraulic power station, has broken down by direct lightning stroke and induced stroke. so, this paper present the stable operation of equipment in switch yard through the improvement of earthing system and the protection to the lightning