• Title/Summary/Keyword: gas shut-off

Search Result 38, Processing Time 0.023 seconds

Proposal and Implementation of Emergency Response System of Gas Shut-off in Earthquake (지진시 도시가스 공급정지를 위한 긴급대응시스템의 제안 및 적용)

  • Jung, Hyo-Soon;Kim, Ick-Hyun;Lee, Jong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.6
    • /
    • pp.25-33
    • /
    • 2008
  • Fires that result from the excessive leakage of gas due to earthquakes cause enormous loss of property as well as numerous human casualties. To prevent such disasters, an emergency gas shut-off system is considered to be one of the effective and rational methods. Considering the seismicity, the earthquake frequency and the gas-supply system of Korea, mass gas shut-off by a gas company is determined to be more cost-effective than individual gas shut-off by customers. In this study, an emergency response system was proposed that would shut off the gas supply immediately. Two different reference seismicities were proposed, to specify rapid response according to the measured seismicity. The gas supply area was divided into several gas shut-off blocks in order to facilitate the shut-off of gas supply in damaged blocks. This proposed system was implemented in the actual gas supply area with reference seismicities on the basis of seismic damage analysis.

Performance Analysis of Emergency Shut-Off Safety Valve (긴급차단용 안전밸브의 성능해석)

  • Song, H. Y.;Park, K. A.;Ko, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.413-418
    • /
    • 2001
  • Emergency shut-on valve was developed to shut off natural gas at the front of a gas meter in the house. The shut-off flow rate and differential pressure of this valve was controlled by adjusting the distance between the spool and magnet. Also the spool shape was an important factor in the performance of this valve. The experimental and computational results will be useful for the design having better performance.

  • PDF

Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder (LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.80-84
    • /
    • 2015
  • In this paper, the valves for a LPG gas cylinder have been investigated on the body height and weight by comparing design data between typical automatic shut-off vertical and newly developed horizontal valves. The height of an automatic shut-off horizontal valve is radically reduced by 41~42% compared with that of a typical automatic shut-off vertical valve. And, the body weight of a horizontal valve is also reduced by 29~40% compared with that of a vertical shut-off valve. This result is just achieved by a structural design modification from typical vertical valve to horizontal arrangement of various valve components.

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF

Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility (고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석)

  • Kim, Myung-Chul;Woo, Jeong-Jae;Lee, Hyung-Sub;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System (CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

Study on the Gas Tight Shut-off Valve of NBC Shelter using Positive Pressure Measurement and Chemical Detection Module (양압측정 및 화학탐지 모듈을 적용한 화생방 방호시설의 가스차단밸브에 관한 연구)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.417-422
    • /
    • 2017
  • One of the most frightening aspects of weapons of mass destruction (WMD) is their ability to cause death in very small quantities without being visible to the public. The military authorities are making considerable effort to ensure the survivability of the combatants in the event of NBC(Nuclear, Biological and Chemical) contamination. Therefore, in this study, modules were developed for the measurement of the positive pressure and for the detection of the chemicals used for the control of the various shut-off valves used in an NBC shelter. In addition, a high performance gas tight shut-off valve was developed that can overcome the disadvantages associated with manual manufacturing, such as the occurrence of defective products and high manufacturing cost. By applying the positive pressure measurement and chemical detection modules, this valve was able to be used to control the facility. The developed gas-tight shut-off valve maintained airtight characteristics at a pressure loss of 28[Pa] at the prescribed wind velocity and an internal pressure of 30[kPa]. It is expected to be possible to control the gas-tight shut-off valve through the remote measurement of the positive pressure, thereby ensuring the foreign independence of import substitution and defense related technology in the future. In addition, by installing these valves in all of the intake ports or exhaust ports connected to the outside of the NBC shelter, it is possible to prevent the damage resulting from the rapid inflow of the storm pressure caused by conventional weapons and nuclear explosions, thereby protecting the people and equipment in the shelter.

Structural Evaluations of the Bellows for a Gas-generator Lox Shut-off Valve (가스발생기 산화제 개폐밸브 주름관 구조 평가)

  • Yoo, Jae-Han;Lee, Joong-Youp;Lee, Soo-Yong;Lim, Hyeong-Tae
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.91-97
    • /
    • 2012
  • The structural analyses and experimental results for the bellows of a gas-generator liquid oxygen shut-off valve were presented. The bellows experiences axial compression and external high pressure loadings at cryogenic temperatures. The analyses were performed using EJMA (Expansion Joint Manufacturing Association) standard and the commercial FE (finite element) analysis program, Abaqus v6.9, at room and cryogenic temperatures. The spring modulus, the induced stress and the expected fatigue life of the bellows were compared respectively. The effects by the contact and the material plasticity on the FE analysis results were also analyzed. Also, FE analyses related to a burst test were presented.

VLD technique for MEAs performance enhancement (MEA의 장기 성능 향상을 위한 VLD 기술 개발)

  • Lim, Sang-Jin;Kim, Hyoung-Juhn;Cho, Eun-Ae;Lee, Sang-Yeop;Lim, Tae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.494-497
    • /
    • 2006
  • For commercialization of polymer electrolytemembrane fuel cell (PEMFC), durability of membrane electrode assemblies (MEAs) has to be improved. Especially, long-term stability of MEA is one of the most important issues for frequent shut-down and start-up processes of PEMFC. The degradation of MEA could be attributed to chemical attack of hydrogen peroxide radicals that are formed at high cell voltages without any special treatment to remove residual hydrogen from anode gas channel after shut-down of the fuel cell. In this study, we investigated the long-term stability of MEA under different on/off operation conditions. Residential hydrogen gas was removed from the anode flow channel by purging air or nitrogen. Also, a dummy resistance was applied to the fuel cell to exhaust residential hydrogen at the anode. In these cases, MEA showed much more stable durability. Electrochemical characteristics of the fuel cell were measured byrepeating the on/off cycles with the hydrogen removal processes. Also, degradation of MEA components was examined by SEM, TEM and XRD analyses.

  • PDF