• Title/Summary/Keyword: gas retention

Search Result 300, Processing Time 0.026 seconds

Characteristics of Anaerobic Acid Fermentation with Food waste leachate by Reactor Type of Retention Time for Landfill Site Injection (매립지 주입을 위한 음폐수 산발효 시 반응기 형태와 체류시간에 따른 특성)

  • Moon, Kwangseok;Kim, Jaehyung;Koo, Hyemin;Lim, Junhyuk;Kim, Nakjoo;Chang, Wonseok;Pak, Daewon
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.125-131
    • /
    • 2014
  • In order to increase landfill gas (LFG) production with food waste leachate, this study was confirmed to be acidogenetic conditions for landfill site injection. Thereby, it was conducted for acidogenetic treatments to determine the decrease in viscosity and VFA production. After acidogenesis treatments, solubility of food waste leachate increased approximately 15%, and as a result, UASB and CSTR were similar by reactor type using the change of retention time. Based on the result of the change in viscosity by reactor type, efficiency of UASB showed approximately 11.38% of higher decrease in viscosity as $76.95{\pm}3.27%$ vs. CSTR. Also, VFA production showed the higher increase of 2.01 times (UASB) and 1.76 times (CSTR) respectively at the point of increasing retention time from 3 to 5 days. From the above results, efficiency of UASB in a reactor was relatively higher because large molecular lead to longer retention time than small molecular due to having screen effect in the fixed media.

Analysis Method of Volatile Sulfur Compounds Utilizing Separation Column and Metal Oxide Semiconductor Gas Sensor

  • Han-Soo Kim;Inho Kim;Eun Duck Park;Sang-Do Han
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.125-133
    • /
    • 2024
  • Gas chromatography (GC) separation technology and metal oxide semiconductor (MOS) gas sensors have been integrated for the effective analysis of volatile sulfur compounds (VSCs) such as H2S, CH3SH, (CH3)2S, and (CH3)2S2. The separation and detection characteristics of the GC/MOS system using diluted standard gases were investigated for the qualitative and quantitative analysis of VSCs. The typical concentrations of the standard gases were 0.1, 0.5, 1.0, 5.0, and 10.0 ppm. The GC/MOS system successfully separated H2S, CH3SH, (CH3)2S, and (CH3)2S2 using a celite-filled column. The reproducibility of the retention time measurements was at a 3% relative standard deviation level, and the correlation coefficient (R2) for the VSC concentration was greater than 0.99. In addition, the chromatograms of single and mixed gases were almost identical.

Headspace gas chromatographic analysis as an objective method for measuring rancidity in soybean oil (Headspace 가스크로마토그라피를 이용한 대두유 산화진행도의 객관적 평가방법)

  • Chun, Ho-Nam;Kim, Ze-Uook
    • Applied Biological Chemistry
    • /
    • v.34 no.2
    • /
    • pp.154-161
    • /
    • 1991
  • An objective method for measuring rancidity in soybean oil was developed based on the volatile contents obtained by headspace gas chromatographic analysis. Apparatus for headspace volatile cold trapping-thermal desorption was described, designed to collect and analyze volatiles of soybean oil. Samples of commercially processed soybean oil were stored under controlled condition and then evaluated for flavor by a eight member trained panel and for volatile contents by headspace gas chromatographic analysis. Twenty-three GC peaks were identified on the basis of relative retention time of reference compounds and gas chromatography-mass spectrometry. The volatile compounds identified were autoxidation products of principal unsaturated fatty acids of soybean oil. The simple linear regressions of flavor score with the pentanal or hexanal contents in aged soybean oil gave correlation coefficient of 0.990 and 0.994. respectively. Pentanal and hexanal contents could be used as a potentially useful index for predicting flavor scores of soybean oil.

  • PDF

Evaluation of vegetable oil rancidity by headspace gas chromatographic analysis (Headspace 가스크로마토그라피를 이용한 식용유의 산패도 측정)

  • Chun, Ho-Nam;Kim, Ze-Uook
    • Applied Biological Chemistry
    • /
    • v.35 no.1
    • /
    • pp.36-41
    • /
    • 1992
  • Several commercial cottonseed, corn and rapeseed oils were stored at $60^{\circ}C\;and\;70^{\circ}C$ with daily exposure of fluorescent light for 12 hours and evaluated their rancidity by headspace gas chromatographic analysis of pentanal and hexanal. The data of gas chromatographic analysis was compared with organoleptic flavor evaluation. For headspace gas chromatographic analysis, the volatile compounds were recovered by porous polymer trap and flushed into a fused silica capillary column at $250^{\circ}C$. Twenty-three GC peaks were identified on the basis of relative retention time of reference compounds and gas chromatography-mass spectrometry. The results showed that the contents of pentanal and hexanal were linearly increased during storage. A very simple linear relationship was found between organoleptic flavor scores and amounts of two volatile compounds with very high correlation coefficient. This results suggested the possible implication of pentanal and hexanal as an quality index for rancidity evaluation of cottonseed, corn and rapeseed oils.

  • PDF

Prediction of Retention Indices of Various Compounds in Gas-Liquid Chromatography (기체-액체 크로마토그래피에서 화합물의 머무름 지표의 예측에 관한 연구)

  • Cha, Gi Won;Lee, Deok Jae
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.108-121
    • /
    • 1994
  • The retention indices of branched-chain alkane, benzene ring, alcohol, amine, ketone, aldehyde and cyclic compounds were measured at 150, 180 and $210^{\circ}C$ on OV-1701 and OV-1 capillary columns. The group retention factors (GRF) of the substituents and the st` ructure retention factors (SRF) of the molecular structure change are derived from the retention indices of reference compounds and series of homologues. The $GRF_f$ equation of `f'th substituent is $GRF_f\;=\;I_{obs}-(100Z + \sum\limits_{i{\neq}f}GRF_i$ + {\sum}$SRF_i$)and the SRFf equation of `f'th molecular structure group is $SRF_f\;=\;I_{obs}-(100Z + {\sum}GRFi + \sum\limits_{i{\neq}f}SRF_i$). The predicted retention indices for those compound were in agreement, within the error of $\pm2$ and $\pm3%$, with the observed values that were obtained using the OV-1701 and OV-1 capillary column, respectively. The $\Delta$ xi of the substituents and $\Delta$ yi of the molecular structure change according to temperature change are derived from the $\Delta'/^{\circ}C$ of reference compounds and series of homologues. The $\Delta$ xi equation of the `f'th substituent is ${\Delta}x_f = {$\Delta}'/^{\circ}C+ \sum\limits_{i{\neq}f}\Delta$ xi + {\sum}{\Delta}yi\;and\;{\Delta}yi$ equation of the `f'th molecular structure group is ${\Delta}y_f$ = {\Delta}'/^{\circ}C+{\sum}{\Delta}xi +\sum\limits_{i{\neq}f}{\Delta}yi$. The predicted $\Delta'/^{\circ}C$ for these compounds were in agreement, within the error of ${\pm}18%$ and 17%, with the observed values that were obtained using the OV-1701 and OV-1 capillary column, respectively.

  • PDF

Gas Chromstographic Analysis of Hydrocarbons in Atmospheric Air around Odae and Ocheon Area (울산군 오대오천부락 근처의 대기 중 탄화수소성분의 가스크로마토그래피에 의한 분석)

  • 양성봉;김영태
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.373-380
    • /
    • 1994
  • Volatile organic compounds in the ambient air were gathered irregularly by normal temperature concentrating method at Odea-ri and Oceon-ri Ulsan-gun in the neighbourhood of Ulsan Petrochemical Industrial Complex and analyzed with gas chromatograph. Several hydrocarbons in common aklospheric air or emitted fugitively from the chemical plants were identified and quantified by comparison with the retention times of standard compounds. The results from several field surveys in 1992 show that the concentrations of styrene at residential area of Odea-ri and Ocheon-ri were less than 0.4 ppm, but once a while greater within the chemical plants area. When it smelled unpleasantly in these area, the concentration of hydrocarbons were also high. It was concluded that the close and long-term investigation about other odorous components but hydrocarbons will be necessary to ascertain the cause of unpleasant odor of these area.

  • PDF

A Study on the Thermal Decomposition of Carbon Tetrachloride by Pyrolytic Incineration (사염화탄소의 열분해 소각에 관한 연구)

  • 이태호;정홍기
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.57-61
    • /
    • 1996
  • This study was to decompose carbon tetrachloride and CFC with pyrolytic incineration unit because of prohibition of their usage sooner or later. We have investigated heating value and temperature versus decomposing rate, removal of $Cl_2$ and dust in the flue gas, The results obtained were as follows; 1. In combustion condition to decompose $CCl_4$ heating value was 3,300Kcal/Kg, retention time was 2,0 sec. incinerator exit temperature was $950^{\circ}C$. 2.The removal of HCI and $Cl_2$ in flue gas used NaOH as reagent, then molar ratio o of $Na^+/Cl^-$ was 1.07. 3. NaCI of dust component was more than 90 %, 2 stage venturi scrubber was used to remove dust, then removal rate of dust was 99% over at L/G of $1.7Vm^3$

  • PDF

Effects of Operating Parameters on Toluene Removal in Dielectric Barrier Discharge Process (무성방전내에서 톨루엔 제거에 미치는 운전변수의 영향)

  • 정재우;이용환;박경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.173-182
    • /
    • 2002
  • We investigated the effects of operating variables, such as electrical. reactor and gas parameters on toluene removal and discharge property in the dielectric barrier discharge (DBD) process. The toluene removal was initiated with the energy transfer to the reactor by loading of voltages higher than the discharge onset value. The energy transfer and toluene removal increased with the applied voltage. Higher removal rate was observed with smooth surface electrode despite of lower energy transfer compared with the coarse electrode, because more uniform discharge can be obtained on smooth surface state. The decrease of dielectric material thickness enhanced the removal efficiency by increasing the discharge potential. The toluene removal efficiency decreased with the increase of the inlet concentration. The increase of gas retention time enhanced the removal efficiency by the increase of energy density. The oxygen and humidity contents seem to exert significant influences on the toluene removal by dominating the generation of electrons, ions, and radicals which are key factors in the removal mechanism.

A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector (열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가)

  • 박정근;유기호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

Thiobacillus ferrooxidans 생물막과 화학적 방법에 의한 항화수소 처리 공정 개발

  • Jeong, Seung-Ho;Jang, Yeong-Seon;Cha, Jin-Myeong;Kim, Tae-Won;Lee, Gwang-Yeon;O, Min-Ha;Park, Don-Hui
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.423-426
    • /
    • 2002
  • A novel process for $H_2S$ gas treatment has been introduced, based on the combined action of a chemical absorption step and a biological step involving the biocatalytic activity of the bacterium Thiobacillus ferrooxidans. The aim of this study is the development of a process for $H_2S$ elimination from gas streams based on that chemical/biological method. The immobilized biomass reactor/chemical adsorption system is suitable for application of the removal of $H_2S$. A double stage reactor was used for the experimental work. The removal efficiencies of over 99% were observed in the range of inlet $H_2S$ concentration from 200 to 1,000ppm. The novel process showed the stable elimination efficiencies of over 95% under the retention time range from 20 to 40sec at the 1,000ppm of $H_2S$ inlet concentration.

  • PDF