• Title/Summary/Keyword: gas quantity

Search Result 479, Processing Time 0.116 seconds

A Study on the Calculation Formulae for the Required Air and Combustion Gas of the Domestic Anthracites (국산무연탄의 소유공기량과 발생연소가스량의 산식에 관한 연구)

  • 이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-33
    • /
    • 1981
  • The characteristics of typical 35 kinds of domestic anthracites among 155 kinds are studied to find the calculation formula for the required quantity of air and the combustion gas quantity. 1) The author's calculation formulae are as follows: ${A_0}={\frac{1, 000}{1, 064}}{H_1}+0.086(Nm^3/kg)$ ${G_0}={\frac{1, 000}{1, 110}}{H_1}+0.234(Nm^3/kg)$(1) Theoretically required quantity of air (2) Theoretical quantity of combustion gas 2) Theoretical quantity of air in combustion of domestic anthracite is always estimated more with Rosin's formula than author's one in the typical domestic anthracites which have the lower calorific value between 3, 000-8, 000 Kcal/kg and the difference of the calculated quantity of air becomes small, as the calorific value increases. 3) Theoretical quantity of combustion gas is estimated more by author's formula than by Rosin's one with the domestic anthracites which have more calorific value than 6, 700 Kcal/kg and is estimated less in the under range of the above calorific value. 4) Theoretical quantity of required air and quantity of combustion gas of domestic anthracite show ${\pm}$4% difference by Rosin's formulae in comparison with results of actual analysis, and about ${\pm}$1.5% by the author's one.

  • PDF

A Study on the Environmental Load of Office Buildings in Seoul

  • Lee, Sang-Hyung;Lee, Yun-Gyu;Yang, Kwan-Seob;Ahn, Tae-Kyung;Lee, Seung-Eon;Park, Hyo-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.58-64
    • /
    • 2001
  • This study is to examine the emission quantity of $CO_2$ gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$ emission quantity of 34 office buildings surveyed is 22.4 kg-c/$m^2$-year, which consists of 17.5 kg-c/$m^2$-year by consurunlelectncif. and 4.9 kg-c/$m^2$-year by consuming natural gas. And the $CO_2$ emission quantity of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by beating load. It is also proposed that the $CO_2$ emission quantity of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

The Development of the Safety Valve for LP Gas Cylinder Using the Sintered Metal (소결금속을 이용한 LPG 용기용 안전 밸브의 개발)

  • Rhim, Jong-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.48-52
    • /
    • 2006
  • This study is a research of safety valve development for LP gas cylinder which use sintering metal. Re-searcher wishes to apply technology of sintering metal for safety valve development and do gas flow control. The basis of this study is most suitable fluid examination that to reduce gas accident. This research concluded following results. 1. When press pin length is 42mm to 45mm powder quantity is 0.25g, in case of press pin length 36mm to 42mm powder quantity is 0.2g, displayed fluid optimization. 2. When press pin length is 39mm and powder quantity is 0.25g, press pressure displayed fluid optimization at all interests from $1.2\;tons/cm^{2}\;to\;2\;tons/cm^{2}$. 3. When apparent density is about $5.0g/cm^{3}\;to\;4.5g/cm^{3}$, fluid optimization becomes.

Analysis of computational fluid dynamics on design of nozzle for integrated cryogenic gas and MQL(minimum quantity lubrication) (극저온 가스와 MQL(minimum quantity lubrication)의 복합 분사를 위한 하이브리드 노즐 설계에 관한 전산유체역학 해석)

  • Song, Ki-Hyeok;Shin, Bong-Cheol;Yoon, Gil-Sang;Ha, Seok-Jae
    • Design & Manufacturing
    • /
    • v.13 no.3
    • /
    • pp.41-47
    • /
    • 2019
  • In conventional machining, the use of cutting fluid is essential to reduce cutting heat and to improve machining quality. However, to increase the performance of cutting fluids, various chemical components have been added. However, these chemical components during machining have a negative impact on the health of workers and cutting environment. In current machining, environment-friendly machining is conducted using MQL (minimum quantity lubrication) or cryogenic air spraying to minimize the harmful effects. In this study, the injection nozzle that can combined injecting minimum quantity lubrication(MQL) and cryogenic gas was designed and the shape optimization was performed by using computational fluid dynamics(CFD) and design of experiment(DOE). Performance verification was performed for the designed nozzle. The diameter of the sprayed fluid at a distance of 30 mm from the nozzle was analyzed to be 21 mm. It was also analyzed to lower the aerosol temperature to about 260~270K.

Distribution of Gas Extruded from Sanitary Landfill (쓰레기 매립지에서 대기중에 유출하는 가스 분포)

  • 이해승;이찬기
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.63-72
    • /
    • 1997
  • This study presents a surveying of methane and carbon dioxide at sanitary landfills. The following results are obtained. (1) The majority of methane and the half of carbon dioxide pour out from vertical gas vents. (2) The quantity of carbon dioxide in cove. soil was greater than methane. (3) Even though gas extrusion in side slop area was small, the quantity of gas extrusion in side slop area was much greater than in coversoil area as especially carbon dioxide rate. (4) As were carried raw refuse layer, methane extrusion was trace, but carbon dioxide was large. (5) Gas extrusion quantity were changed by the compaction of soil, and the operating area of refuse. (6) Carbon dioxide portioned much larger in the whole landfill, but methane portioned much larger in gas vent and coversoil.

  • PDF

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

MOLECULAR SCALE MECHANISM ON EVAPORATION AND REMOVAL PROCESS OF ADHERENT MOLECULES ON SURFACE BY BURNT GAS

  • Yang, Y.J.;Lee, C.W.;Kadosaka, O.;Shibahara, M.;Katsuki, M.;Kim, S.P.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • The interaction between adherent molecules and gas molecules was modeled in the molecular scale and simulated by the molecular dynamics method in order to understand evaporation and removal processes of adherent molecules on metallic surface using high temperature gas flow. Methanol molecules were chosen as adherent molecules to investigate effects of adhesion quantity and gas molecular collisions because the industrial oil has too complex structures of fatty acid. Effects of adherent quantity, gas temperature, surface temperature and adhesion strength for the evaporation rate of adherent molecules and the molecular removal mechanism were investigated and discussed in the present study. Evaporation and removal rates of adherent molecules from metallic surface calculated by the molecular dynamics method showed the similar dependence on the surface temperature shown in the experimental results.

A Statistical Model for Predicting Incipient Point and Quantity of Gas Condensate in Gas Pipelines (가스 배관내 가스 컨덴세이트의 발생 시작점 및 발생량 예측을 위한 통계 모델 연구)

  • Chang, Seung-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.1-5
    • /
    • 2006
  • With the rapid increase in gas consumption, the role of pipelines as a transportation means of natural gas is increasing. In general, when natural gas is being transported in pipelines, some liquid mainly from formation of condensate is introduced and this phenomenon makes operational problems more complex in the gas industry. Thus, an appropriate method is necessary for predicting the effect of presence of gas condensate on operational efficiency. In this study, a statistical model was developed using an integrated single- and two-phase flows concept. Using this model, the effects of the incipient point of gas condensate and its quantity on outlet pressure were analyzed. Also, the effect of variations of flow regimes in two-phase region on outlet pressure after the incipient point was analyzed.

  • PDF

Density Measurement Comparisons of Specific Gravity Meter and Gas Chromatography in the Field (실제조건에서 기준 밀도계와 가스 분석기에 의한 밀도 측정 결과 비교)

  • Lee, Kang-Jin;Her, Jae-Young;Ha, Young-Cheol
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.90-96
    • /
    • 1999
  • In contracts for sales of natural gas between sellers and buyers, it is not suncient to only measure a volumetric quantity of gas in flowing conditions in metering station. Therefore the measured volumetric quantity must be converted to that of reference conditions. The density of the natural gas required in such a calculation can be measured directly or estimated from the equation of sate or any other experimental methods. The specific gravity meter is the apparatus used to measure the density of fluids under the reference conditions and it can be widely used in industrial areas, especially in massive flow rate natural gas industry. This study has been carried out in an attempt to improve measurement accuracy of natural gas flow rate calculation, providing the adequate installation and proper operation conditions of specific gravity meter. The test results are 1) the density measurement errors in case of using methane and standard gas as calibration gases are smaller than using methane and nitrogen gas, 2) the periodical calibration to maintain accurate density measurements is essential, and 3) the specific gravity meter is sensitive to changes of environmental conditions, especially environmental temperature surrounding the specific gravity meter.

  • PDF

Low-Carbon Information Management of Street Lamps and Street Trees Using GIS (GIS를 이용한 가로등 및 가로수의 저탄소 정보 관리)

  • Choi, Byoung Gil;Na, Young Woo;Kwon, Oh Sub
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.1
    • /
    • pp.55-62
    • /
    • 2014
  • Diverse improvement projects such as replacing street lamps with LED, street trees, etc are currently in progress in Korea to reduce greenhouse gas so as to cope with change in climate. However, the effect of climate change policy is not exactly analyzed, because exhaust quantity and absorption quantity of greenhouse gas of the target street lamp and street trees are not arranged as information. Thus, this study studied the method to systematically manage low carbon related information of urban facilities by using GIS. It was found that low carbon information of the urban facilities is necessary to exactly analyze effect of climate change policy and the method to calculate carbon exhaust quantity and absorption quantity of each facilities should be established to build exact low carbon information of urban facilities. Further, it was found that the visualization of information related to low carbon of street lamp and street trees by using GIS easily and visually grasps and systematically controls the effect of policy coping with change in climate than the existing numeral data of exhaust quantity and absorption quantity of greenhouse gas.