• 제목/요약/키워드: gas measurement method

검색결과 642건 처리시간 0.02초

페블 베드 타입 고온 가스 냉각 원자로 내부 유동장 측정 (Measurement of Flow Field in the Pebble Bed Type High Temperature Gas-cooled Reactor)

  • 이사야;이재영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2088-2093
    • /
    • 2008
  • In this study, flow field measurement of the Pebble Bed Reactor(PBR) for the High Temperature Gas-cooled Reactor(HTGR) was performed. Large number of pebbles in the core of PBR provides complicated flow channel. Due to the complicated geometries, numerical analysis has been intensively made rather than experimental observation. However, the justification of computational simulation by the experimental study is crucial to develop solid analysis of design method. In the present study, a wind tunnel installed with pebbles stacked was constructed and equipped with the Particle Image Velocimetry(PIV). We designed the system scaled up to realize the room temperature condition according to the similarity. The PIV observation gave us stagnation points, low speed region so that the suspected high temperature region can be identified. With the further supplementary experimental works, the present system may produce valuable data to justify the Computational Fluid Dynamics(CFD) simulation method.

  • PDF

전력시스템 고조파 상태 춘정에서 GA를 미용한 최적 측정위치 선정 (Optimal Placement of Measurement Using GAs in Harmonic State Estimation of Power System)

  • 정형환;왕용필;박희철;안병철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.471-480
    • /
    • 2003
  • The design of a measurement system to perform Harmonic State Estimation (HSE) is a very complex problem. Among the reasons for its complexity are the system size, conflicting requirements of estimator accuracy, reliability in the presence of transducer noise and data communication failures, adaptability to change in the network topology and cost minimization. In particular, the number of harmonic instruments available is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents a new HSE algorithm which is based on an optimal placement of measurement points using Genetic Algorithms (GAs) which is widely used in areas such as: optimization of the objective function, learning of neural networks, tuning of fuzzy membership functions, machine learning, system identification and control. This HSE has been applied to the Simulation Test Power System for the validation of the new HSE algorithm. The study results have indicated an economical and effective method for optimal placement of measurement points using Genetic Algorithms (GAs) in the Harmonic State Estimation (HSE).

A Method for the Measurement of Methane Gas Based on Multi-beam Interferometry

  • Ye, Jiansen;Li, Zhuo
    • Journal of the Optical Society of Korea
    • /
    • 제17권6호
    • /
    • pp.481-485
    • /
    • 2013
  • A method for the measurement of the concentration of methane is experimentally demonstrated. The wavelength filter and gas cell are combined by using one Fabry-Perot etalon, which is filmed with the reflectivity of 96%. The optical broadband source is not only filtered to match the absorption wavelength of methane, but also absorbed by the methane in the same Fabry-Perot etalon. The concentration of the methane can be detected directly by measuring the transmission intensity. Compared with the conventional method, the proposed method possesses low costand high stability.

초음파를 이용한 대형볼트 신장량 및 체결력 측정연구 (The Study on Elongation and Torque Measurement in Large Bolt by using Ultrasonic Technology)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제13권3호
    • /
    • pp.40-46
    • /
    • 2009
  • This study on the bolt elongation and torque measuring method by ultrasonic nod-destructive method. In the past, The dial gage was used for the elongation measurement of gas turbine bolts. The purpose of this study is to improve the traditional bolt elongation measurement method. The old method using dial gage measures the elongation of the gas turbine bolt. If the length differences among the loading bolts are within the required range, The loading torques of bolts consider as acceptable. But this method can not give the information about torque differences among the loading bolts. It could bring out vibration of turbine due to loading torque differences among the bolts. So the elongation and torque must be measured simultaneously. The new technology using ultrasonic non-destructive method can give the information about bolt elongation and torque. The ultrasonic method basically measures the speed in the bolt material for the calculation the bolt elongation. But the ultrasonic speed varies according to temperature and loading torque of bolts. So the factors of temperature and loading power were investigated and reflected to the calculation of bolt elongation and torque. The results of this study shows the big difference among the bolts torque in the old method and the torque differences among the bolts can be adjusted by reflecting the result of this study. And this torque adjusting method can decrease gas turbine vibration problem due to torque difference among the bolts. So this paper shows ultrasonic method is better than old method for the measurement of bolt elongation and torque.

  • PDF

전달 시간차 방식 초음파 가스 유량계 (Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference)

  • 박상국;황원호
    • 제어로봇시스템학회논문지
    • /
    • 제9권9호
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법 (Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD)

  • 정지연;박승현;이광용;오세민
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

부피 분석법을 이용한 고무 소재의 수소 기체 장입량 및 확산도 측정 기술 개발 (Development of Measurement Technology for Uptake and Diffusivity of Hydrogen gas in Rubber Materials using Volumetric Analysis)

  • 이지훈;정재갑;백운봉;정기수
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.67-76
    • /
    • 2022
  • We developed a technology that can measure the hydrogen uptake and diffusivity of rubber materials by using the volumetric analysis method and diffusivity analysis program through the measurement of the water level in the graduated cylinder. In this method, hydrogen gas is charged at a certain pressure for a certain period of time for a rubber material exposed to a high-pressure hydrogen gas environment, and then the pressure is reduced to measure the change in the water level in the graduated cylinder in real time, and based on the measured value, it is a technology that can evaluate hydrogen uptake and diffusivity using diffusivity analysis program. Using this method, the hydrogen uptake and diffusivity of the NBR material were measured with respect to the change in the type and weight ratio of the filler used to improve the physical properties of the rubber material. In addition, uncertainty analysis was performed on the diffusivity measurement method.

Soil-Gas의 분석을 이용한 휘발성 유기화합물 오염도 신속측정 (Rapid Measurement of VOC Using an Analysis of Soil-Gas)

  • 김희경;조성용;황경엽
    • 한국토양환경학회지
    • /
    • 제3권1호
    • /
    • pp.3-9
    • /
    • 1998
  • 본 연구는 휘발성 유기 화합물로 오염된 가솔린 지역에서 soil-gas의 분석결과로부터 오염도를 유추하는 기법에 대하여 서술 하였다. Soil-gas의 채취방법으로는 펌프를 이용한 1)grab sampling법과 흡착제 trap을 사용한 2)passive sampling법이 있다. Grab sampling법은 특정시간에 특정장소에서의 오염도를 보여주며, 반면에 passive sampling법은 특정위치에서 시간에 따른 오염도의 변화를 보여 준다. Soil-gas의 분석은 1)PID나 FID와 같은 작은 검지기에 의해서 총괄 탄화수소량을 측정할수도 있고 2)기체농도에 따라서 색깔이 변하는 지시약이 채워진 기체검지기 튜브를 사용할수도 있으며 3)여러가지 화합물을 한 번에 분석할수 있는 이동형 GC를 사용할수도 있다. Soil-gas를 이용한 측정법은 매우 값싸며 세밀한 정밀조사를 하기 위한 전단계에서 사용할 수 있는 유용한 방법으로 추천할만하다 하겠다.

  • PDF

고등어 조리 시 발생하는 미세먼지의 입경 분석 (Diameters Analyses of Fine Particles Emitted When Mackerels Cooked)

  • 김성미;이임학;이경빈;김진식;권명희
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.361-369
    • /
    • 2017
  • In this study, the characteristics of the dust emission according to the presence or absence of operation of the gas stove were analyzed by particle size analysis and density estimation while the mackerel was cooked while the fan was placed on the gas stove used in the home. The experiment was carried out using 20 mackerel of normal size at home. Commercially available canola oil was used as edible oil. In order to understand the characteristics such as particle size distribution of fine dust, light scattering measurement method which can be measured at intervals of several seconds was used. Particles generated by combustion of gas stove, particles formed by heating cooking oil, and particles generated by heating mackerel fish meat are judged to be nano size particles smaller than $1{\mu}m$. Therefore, it is necessary to use precise measurement method rather than the measurement method using the filter which is currently being measured in the measurement of the particles discharged from the fuel combustion or food cooking in the future. Analyzing the particle size and density of the dust emitted from the cooking stove is expected to contribute technically to the reduction of dust emissions from the cooking process of gas and fuel facilities at home and commercial facilities.

가스터빈엔진 고공성능시험설비의 측정불확도 개선 (Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines)

  • 이대성;양인영;전용민;김춘택;양수석
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.