• Title/Summary/Keyword: gas mass spectrometer

Search Result 225, Processing Time 0.034 seconds

Implementation of a Portable Electronic Nose System for Field Screening (필드 스크린을 위한 휴대용 전자코 시스템의 구현)

  • Byun, Hyung-Gi;Lee, Jun-Sub;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • There is currently much interest in the development of instruments that emulate the senses of humans. Increasingly, there is demand for mimicking the human sense of smell, which is a sophisticated chemosensory system. An electronic nose system is applicable to a large area of industries including environmental monitoring. We have designed a protable electronic nose system using an array of commercial chemical gas sensors for recognizing and analyzing the various odours. In this paper, we have implemented a portable electronic nose system using an array of gas sensors for recognizing and analyzing VOCs (Volatile Organic Compounds) in the field. The accuracy of a portable electronic nose system may be lower than an instrument such as GC/MS (Gas Chromatography/Mass Spectrometer). However, a portable electronic nose system could be used on the field and showed fast response to pollutants in the field. Several different algorithms for odours recognition were used such as BP (Back-Propagation) or LM-BP (Levenberq-Marquardt Back-Propagation). We applied RBF (Radial Basis Function) Network for recognition and quantifying of odours, which has simpler and faster compared to the previously used algorithms such as BP and LM-BP.

Characteristics of PM2.5 Carbonaceous Aerosol using PILS-TOC and GC/MS-TD in Seoul (PILS-TOC 및 GC/MS-TD를 이용한 서울시 대기 중 초미세먼지(PM2.5) 유기탄소의 특성 분석)

  • Park, Da-Jeong;Ahn, Joon-Young;Shin, Hye-Jung;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.461-476
    • /
    • 2014
  • Continuous Water-Soluble Organic Carbons (WSOC) by the Particle Into Liquid Sampler - Total Organic Carbon (PILS-TOC) analyzer were measured at the Seoul intensive monitoring site from June 17 through July 5 in 2014. In addition, the 24 hour integrated PM2.5 collected by Teflon and Quartz filters were analyzed for water soluble ions by Ion chromatography (IC), WSOC by TOC from water extracts, organic carbon (OC), elemental carbon (EC) by carbon analyzer using the thermal optical transmittance (TOT) method, and mass fragment ions (m/z) related to alkanes and PAHs (Poly Aromatic Hydrocarbons) by Gas Chromatography-Mass Spectrometer-Thermal Desorption (GC/MS-TD). Based on the statistical analysis, four different Carbonaceous Thermal Distributions (CTDs) from OCEC thermal-gram were identified. This study discusses the primary and secondary sources of WSOC based on the Classified CTD, organic mass fragments, and diurnal patterns of WSOC. The results provide knowledge regarding the origins of WSOC and their behaviors.

Discrimination of Ginseng Habitat by Using Instrumental Analysis Techniques

  • Sohn H. J.;Lee S. K.;Cho B. G.;Kim S. J.;Lee N. Y.;Choi D. S.;Jeong M. S.;Bae H. R.;Yang J. W.
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.238-252
    • /
    • 2002
  • In order to screen out indicators for the discrimination of ginseng habitat, some physical and chemical characteristics of Korean red ginsengs (94 kinds) and Chinese red ginsengs (50 kinds) were analyzed by using a rheometer, an electronic nose system, a combined technique of solid phase micro-extraction (SPME) and gas chromatograph equipped with an electron capture detector (GC/ECD), an X-ray fluorescence spectrometer (XRF), an inductively coupled plasma mass spectrometer (ICP/MS), a near infrared spectrometer (NIRs) and high performance liquid chromatography equipped with evaporative light scattering detector (HPLC/ELSD). The results are summarized as follows: (i) The rhizome strengths of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. (ii) The electronic nose patterns of Korean red ginsengs were significantly different from those of Chinese red ginsengs. (iii) Some unidentified peaks were detected not in the headspace of Korean red ginsengs but in the headspace of Chinese red ginsengs when the headspace volatiles prepared by the SPME technique were analyzed by GC/ECD. (iv) Either the content ratios of K to Ca or Mn to Fe were significantly different between Korean red ginsengs and Chinese red ginsengs. (v) The reflectance ratios of NIRs wavenumbers such as $904\;cm^{-1}\;to\;1088\;cm^{-1}$ for Korean red ginsengs were significantly different from those for Chinese red ginsengs. (vi) The content ratios of ginsenoside-Rg to ginsenoside-Re of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. These results indicate that the rhizome strength, the electronic nose pattern, the occurrence of ECD-sensitive headspace volatile components, the content ratios of K to Ca and Mn to Fe, the NIRs pattern and the content ratio of ginsenoside-Rg to -Re may be indicators for the discrimination of ginseng habitat.

  • PDF

Dissolved Methane Measurements in Seawater and Sediment Porewater Using Membrane Inlet Mass Spectrometer (MIMS) System (Membrane Inlet Mass Spectrometer (MIMS) 시스템을 이용한 해수 및 퇴적물 공극수내 용존 메탄의 측정)

  • An, Soon-Mo;Kwon, Ji-Nam;Lim, Jea-Hyun;Park, Yun-Jung;Kang, Dong-Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2007
  • Membrane inlet mass spectrometer (MIMS) has been used to accurately quantify dissolved gases in liquid samples. In this study, the MIMS system was applied to measure dissolved methane in seawater and sediment porewater. To evaluate the accuracy of the measurement, liquid samples saturated with different methane partial pressure were prepared and the methane concentrations were quantified with the MIMS system. The measured values correspond well with the expected values calculated from solubility constants. The standard error of the measurements were $0.13{\sim}0.9%$ of the mean values. The distribution of dissolved methane concentration in seawater of the South Sea of Korea revealed that the physical parameters primarily control the methane concentration in sea water. The MIMS system was effective to resolve the small dissolved methane difference among water masses. The probe type inlet in MIMS system was proven to be effective to measure porewater methane concentration.

Development of the Ion Source of Glow Discharge/Mass Spectrometry for the determination of trace elements (미량원소 분석을 위한 GD/MS 이온원의 개발에 관한 연구)

  • Woo, Jin Chun;Lim, Heoung Bin;Moon, Dae Won;Lee, Kwang Woo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.169-176
    • /
    • 1992
  • Analytical detection limits and Relative Ion Yield (RIY) by a jet type ion source glow discharge mass spectrometer(GD/MS) have been measured. With a jet type ion source, the sample loss rate for a Cu sample is 0.23 mg/min with 0.1 L/min gas flow rate and 0.11 mg/min with no gas flow rate. However, the ion intensity of Cu does not change significantly with thee variation of the gas flow rate. The RIY values obtained from the calibration curves of the six copper based standards were between 0.57 of Fe and 3.5 of Cr. The detection limits of most elements were in the range of 0.9 and 2.0 ppm when the glow discharge was operated at 4 mA, 1000V.

  • PDF

Feasibility study of membrane interface for gas chromatograph-mass spectrometry (기체크로마토그래프-질량분석기의 실리콘 분리막 인터페이스의 유용성 연구)

  • Kang, Gil Seon;Lee, Dong Soo;Lee, Hwa Sim;Park, Chang Joon
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.495-501
    • /
    • 2008
  • Agilent 5973 GC-MS instrument was modified so that the capillary direct interface was removed and that a silicone membrane was installed between GC and MS. Feasibility study of the membrane interface GC-MS has been carried out. Vacuum of the mass spectrometer was not affected by the carrier gas flow rate up to $4.7m{\ell}/min$. As the carrier flow rate was increased, peak tailing was reduced and chromatogram peaks appeared earlier. Chromatogram peaks showed better separation and higher sensitivity as the membrane thickness was reduced from $127{\mu}m$ to $75{\mu}m$, and also as the interface temperature was increased. However, the membrane interface GC-MS had drawbacks such as background ions at 73 and 147 m/z and poor peak separation due to peak tailing.

Determination of dichloroacetic acid and trichloroacetic acid in fresh-cut salads using gas chromatography-mass spectrometry (GC-MS를 이용한 신선편의 샐러드 중 dichloroacetic acid와 trichloroacetic acid의 분석)

  • Kim, Hekap;Lee, Seong-gyun;Yun, A-hyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.1
    • /
    • pp.12-17
    • /
    • 2019
  • Dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) in fresh-cut salads available from the market were determined by gas chromatography-mass spectrometry (GC-MS). The target compounds in 3 g of acidified homogenates were extracted with 20 mL of methyl t-butyl ether (MTBE). The extract was concentrated to 1 mL and heated for 1 h at $55^{\circ}C$. The analytes were separated using a DB-1701 column and detected with a mass spectrometer. The method detection limit was approximately $6{\mu}g/kg$, and both analytical accuracy and precision were found to be satisfactory. The linearity of the calibration curves expressed as the coefficients of determination was >0.996. The analysis of seven samples using the established method showed that the four samples contained considerable amounts of analytes ($25.4-31.2{\mu}g/kg$ of DCAA and $18.8-46.1{\mu}g/kg$ of TCAA). These results raised a concern about the impact of fresh-cut salad consumption on human health.

Association of Persistent Organic Pollutants (POPs) with Age and Body Mass Index in Korean Adults (한국 성인의 혈청 잔류성 유기오염물질 농도와 연령 및 체질량지수와의 관련성)

  • Moon, Ho Jung;Lim, Jung-Eun;Jee, Sun Ha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.442-453
    • /
    • 2014
  • Objectives: Persistent organic pollutants (POPs) are known to be the detrimental chemicals in the body, even at low levels, and are stored in adipose tissue. Recently, POPs have been reported to be associated with chronic diseases, including cancer and cardiovascular disease, and aging and obesity are reported as common factors in chronic disease. However, there have been only a few studies on the associations of POPs with age and body mass index (BMI) in Korea. Therefore, we analyzed the associations of serum POPs levels with age and BMI in Korea. Methods: This cross-sectional study includes 444 subjects (253 men and 191 women) from the Korean Cancer Prevention Study-II (2004-2011). Serum levels of 33 polychlorinated biphenyls (PCBs) and 19 organochlorine pesticides (OCPs) were measured by a gas chromatographer (Agilent 6890) coupled to high resolution mass spectrometer (JEOL JMS-800D). Results: Concentrations of PCB 153 (men: 12.26 ng/g lipid, women: 10.50 ng/g lipid) and p,p'-DDE (men: 94.66 ng/g lipid, women: 96.66 ng/g lipid) were the highest among serum PCBs and OCPs, respectively. PCBs and OCPs were significantly positively correlated with age in both sexes. After adjustment for age, non-dioxin like PCBs were significantly negatively correlated with body mass in women. However, cis-heptachlor epoxide was significantly positively correlated with body mass index in both sexes. When analyzed by sex, stronger associations were shown between POPs and age in men and POPs and BMI in women. Conclusion: These results may provide baseline data for the study of POPs and for the health management field in Korea.

Dynamic Headspace Analysis of Volatile Constituents of Swiss Cheese Whey Protein Concentrate

  • Ha, E.Y.W.;Lee, S.J.;Jung, E.J.;Lee. Y.B.;Morr, C.V.
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.3
    • /
    • pp.299-304
    • /
    • 2002
  • Volatile flavor compounds in the headspace of swiss cheese whey protein concentrate (WPC) were analyzed by dynamic headspace analyzer, gas chromatography, and mass spectrometer. Sixty one compounds were detected from the headspace of dry WPC and 23 compounds from the headspace of an aqueous solution of WPC. The major components were propanol, hexanal, 2-butanone, 2-pentanone, 2,3-butanedion, 2-propanol, acetic acid, dimethyl disulfide and benzothiazole. An external dynamic headspace sampler, devised for this study, effectively collected volatiles from the headspace of dry WPC and aqueous WPC solutions.

Synthesis of Aminofuroxan Derivatives for the Alkyne Formation on Solid Surface and e-Beam Mediated Fragmentation in Gas Phase (고체상 표면에서 알카인 생성을 위한 아미노퓨록산 유도체의 합성과 전자빔에 의한 기체상 분해반응)

  • Heo, Jeong-Mu;Kim, Gi-Young;Hwang, Kwang-Jin
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.2
    • /
    • pp.160-164
    • /
    • 2007
  • Aminofuroxan derivatives 3 and 4 were prepared by the reaction of chlorofuroxan 2 with butyl and benzyl amines, respectively. E-beam mediated fragmentation of aminofuroxans 3, 4 in mass spectrometer was analyzed in a view of the corresponding alkyne formation.