• 제목/요약/키워드: gas leak & sensor

검색결과 41건 처리시간 0.023초

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

메탄 가스 기반 가스 누출 위험 예측을 위한 다변량 특이치 제거 (Multivariate Outlier Removing for the Risk Prediction of Gas Leakage based Methane Gas)

  • 홍고르출;김미혜
    • 한국융합학회논문지
    • /
    • 제11권12호
    • /
    • pp.23-30
    • /
    • 2020
  • 본 연구에서는, 천연가스(NG) 데이터와 가스 관련 환경 요소 간의 관계를 기계학습 알고리즘을 사용하여 가스 누출 데이터를 직접 측정하지 않고 가스 누출 위험 수준을 예측하였다. 이번 연구는 서버가 제공하는 오픈 데이터인 IoT 기반 원격 제어 피카로(Picarro) 가스 센서 사양을 기반으로 사용했다. 천연 가스는 공기 중으로 누출이 되며, 대기 오염, 환경, 그리고 건강에 큰 문제가 된다. 본 연구에서 제안하는 방법은 천연 가스의 누출 위험 예측을 위한 랜덤 포레스트(Random Forest) 분류 기반 다변량 특이치 제거 방법이다. 비지도 k-평균 클러스터링 후에 실험 데이터 집합은 불균형 데이터이다. 따라서 우리는 제안된 모델이 중간과 높은 위험 수준을 가장 잘 예측할 수 있다는 점에 초점을 맞춘다. 이 경우 각 분류 모델에 대한 수신자 조작 특성(ROC) 곡선, 정확도, 평균 표준 오차(MSE)를 비교했다. 실험 결과로 정확도, 수신자 조작 특성의 곡선 아래 영역(AUC, Area Under the ROC Curve), MSE가 각각 MOL_RF의 경우 99.71%, 99.57%, 및 0.0016의 결과 값을 얻었다.

IoT 기반 산업용 밸브 안전관리 시스템 구성장치의 성능검증 방안 개발 (Development of Performance Verification Method for Components of IoT-based Industrial Valve Safety Management System)

  • 김재옥;유근준;이경식;김정훈
    • 한국가스학회지
    • /
    • 제24권5호
    • /
    • pp.10-19
    • /
    • 2020
  • 석유화학 플랜트 및 가스 시설물의 밸브 사고는 심각한 인적·물적 피해를 유발하며 이러한 시설에서의 주요사고 원인은 밸브에서의 가스 누출로 인한 흡입, 중독, 화재 및 폭발사고이다. 가스 누출을 예방하기 위한 점검은 인력에 의해 직접 검사가 이루어지는 경우가 많으며, 점검자는 가스 누출사고의 위험에 직접적으로 노출된다. 이러한 사고를 예방하기 위하여 IoT 기반 위험 분석 및 위험성 평가 모니터링 시스템과 자동제어 시스템을 적용하였다. 이를 통하여 산업용 밸브의 내·외부 가스 누출을 검지하고 하이브리드 센서를 통한 국부 및 전역 센싱으로 플랜트 현장에서의 밸브 이상으로 인한 사고를 실시간으로 모니터링 할 수 있다. 이와 같이 새로운 산업용 밸브 안전관리 시스템이 개발됨에 따라 관련 구성장치에 대한 성능 및 현장부합성에 대한 평가방안이 요구되었다. 본 연구에서는 산업용 유무선 통신을 지원하고 가스센서와 광섬유센서를 포함하는 방폭형 하이브리드 센싱 시스템과 자동제어가 가능한 액추에이터 패키지의 성능을 평가하기 위한 시험 항목 및 방법을 제시하였고 시스템의 신뢰성을 확보할 수 있는 구성장치의 성능검증 방안을 개발하였다.

Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템 (Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor)

  • 박재현;이시맥;이범주;김선주;유형민
    • Composites Research
    • /
    • 제36권6호
    • /
    • pp.429-434
    • /
    • 2023
  • 본 연구에서는 기존 배관 가스 누출 감지에 사용되던 음향방출 센서가 실시간 모니터링에 적용될 때 발생할 수 있는 문제들을 개선하기 위해, Macro-fiber composite (MFC) 트랜스듀서를 음향방출 센서로 사용하여 가스 누출 감지 시스템에 적용하였다. 적용 전 MFC의 구조를 최적화하기 위해 구조해석을 진행하여 제작하였고, 그 결과 MFC가 가지는 유연성으로 굴곡진 배관에 잘 밀착되어 AE 신호를 문제없이 수신할 수 있었다. AE 신호 분석 결과 고압 누출, 저압 누출 모두 파라미터 값 변화에 유의미한 결과를 보였으며, 특히, FFT 그래프의 파라미터에서 고압 누출의 경우 누출이 없는 경우 대비 120~626%의 변화량, 저압 누출의 경우 9~22%의 변화량을 보였다. 또한, 누출 발생 부위에서의 거리에 따라, 거리가 멀수록 이러한 파라미터 변화량이 줄어드는 경향을 보여, 추후 파라미터 변화량 감지를 통해 누출 감지가 가능할 뿐만 아니라, 변화량으로부터 누출 발생 위치를 파악할 수 있을 것으로 보인다.

IOT기술을 이용한 유무선 통합 가스검출 시스템 구현 (System of gas sensor for conbinating wire and wireless using Internet of Things)

  • 방용기;강경식
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.297-304
    • /
    • 2015
  • This study concerns the integrated gas sensor system of wire and wireless communication by using IoT(Internet of Things) technology. First, communication part is that it delivers the detection information, which transferred by wire or wireless communication and required control procedure based on a wireless module that receives the gas leakage information from wired or wireless detector, to administrator or user's terminal. Second, receiver part is that it shows the location and information, which received from the wired detector formed by a detecting sensor's node as linking with the communication part, and transfers these to the communication part. Third, wireless detector formed as a communication module of a detecting sensor node is that it detects gas leakage and transfers the information through wireless as a packet.Fourth, wired detector communicated with the receiver part and formed as a communication module of a detecting sensor node is that it detects gas leakage, transfers and shows the information as a packet. Fifth, administrator's terminal is that it receives gas leakage information by the communication part, transfers the signal by remote-control, and shut off a gas valve as responding the information. Sixth, database is that it is connected with the communication part; it sets and stores the default values for detecting smoke, CO., and temperature; it transfers this information to the communication part or sends a gas detecting signal to user's terminal. Seventh, user's terminal is that it receives each location's default value which stored and set at the database; it manages emergency situation as shutting off a gas valve through remote control by corresponding each location's gas leakage information, which transferred from the detector to the communication part by wireless.It is possible to process a high quality data regarding flammable or toxic gas by transferring the data, which measured by a sensor module of detector, to the communication part through wire and wireless. And, it allows a user to find the location by a smart phone where gas leaks. Eventually, it minimizes human life or property loss by having stability on gas leakage as well as corresponding each location's information quickly.

가스누출 감지용 실리콘 압저항형 절대압센서의 제조 및 온도보상 (Fabrication and Temperature Compensation of Silicon Piezoresistive Absolute Pressure Sensor for Gas Leakage Alarm System)

  • 손승현;김우정;최시영
    • 센서학회지
    • /
    • 제7권3호
    • /
    • pp.171-178
    • /
    • 1998
  • SDB 웨이퍼를 이용하여 실리콘 압저항형 절대압센서를 제조하고 이를 가스누출 감지시스템에 응용하였다. 이 경우 센서는 $0{\sim}600\;mmH_{2}O$, $0{\sim}100^{\circ}C$의 압력, 온도범위에서 정상적으로 동작하여야 하고 다이아프램이 파괴되었을 때 가스가 소자 외부로 누출되어서는 안된다. 따라서 다이아프램 내의 공극을 유리(Pyrex7740)와 진공중($10^{-4}$ torr)에서 양극 접합을 행하였다. 제조된 센서는 압력에 대하여 우수한 선형특성을 보였고, 압력감도는 대기압이상 $0{\sim}600\;mmH_{2}O$의 압력범위에서 $4.06{\mu}V/VmmH_{2}O$ 이었다. 온도보상 일체화 조건을 조사하기 위해 Al 박막저항을 제조하여 온도보상을 행하였는데 오프셋의 온도 drift는 80 %이상, 감도의 온도의존성은 95 %이상 보강 효과를 얻었다. 또한 다이오드(PXIN4001)를 이용한 온도보상시 오프셋의 온도 drift는 98 %이상, 감도의 온도의존성은 90%이상 보상 효과를 나타내었다.

  • PDF

아두이노와 가스센서를 이용한 가스 누출 감지 시스템 (A gas leak detection system using Arduino and gas-sensor)

  • 안성혁;박두순
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 추계학술발표대회
    • /
    • pp.868-869
    • /
    • 2016
  • 인류에게 가스는 주된 에너지원이며 현재에도 우리는 편리하게 가스를 사용하고 있다. 가스 감지에 대한 연구들이 많지만 대부분은 가정에서 사용하기엔 너무 비용이 많이들거나, 기능이 너무 부실하다. 따라서 본 논문에서는 기존의 방법들보다 비용이 절감되고 가스 누출 상황에 대해 좀 더 빠르고 정확하게 대응할 수 있는 아두이노와 가스센서를 통해 가스를 감지하고 안드로이드 어플리케이션을 통해 사용자에게 경고하며, 소방서에 문자메시지를 보낼 수 있는 시스템을 제안한다.

가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구 (A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection)

  • 최영규
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.369-374
    • /
    • 2021
  • 최근에 건설되는 아파트는 주방이 빌트인 방식으로 만들어지므로 가스 호스가 싱크대 내부에 보이지 않게 만들어지므로 가스가 누출될 경우 싱크대 내부에 축적되어 가스 폭발로 이어질 수 있는 위험한 방식이다. 본 연구에서는 가스레인지와 중간밸브 사이에 연결된 호스가 싱크대 내부에 있어 가스 누출 검사를 할 수 없는 구조로 되어 있어 압력센서를 이용하여 가스누출을 검사를 쉽게 할 수 있는 밸브 시스템 연구하였다. 압력 측정 방법은 중간밸브와 가스레인지를 연결하는 호스의 압력을 측정하여 I2C통신 방식으로 데이터를 수집·분석 할 수 있도록 진행하였다. 또한 가정에 공급되는 가스압력계산은 대기압력에 가스계량기의 입구에서 가스게이지 압력 평균값 22.46mbar를 더 한 값으로 계산된 것에 대한 대기 압력 오차에 대한 규명 및 미세한 가스 누출 감지를 할 수 있도록 밸브 시스템을 개발하였다.

치매 환자를 위한 스마트 캐어 시스템 구현 (The implementation of Smart Care System for Dementia Patients)

  • 하은실
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3832-3840
    • /
    • 2014
  • 고령화 사회로 급격히 진행 함에 따라 치매 환자 또한 급속히 증가하고 있으나 진행이 되면 완치가 어려운 실정이다. 초기에 발견하고 진행 과정을 늦추는 것이 치료의 목표이고 환자의 안전, 지속적인 보살핌, 일상 생활, 건강 관리지원이 중요하다. 본 논문의 스마트 케어 시스템은 동작 감지 센서, 가스 누출 감지 센서를 활용한 블루투스 통신 기술을 사용하여 화재, 가스 누출, 가출시 배회등의 각종 응급 상황에 대처 할 수 있게 해주고, 스마트폰을 통해 환자의 일상 생활 수행능력을 지속적으로 관찰, 관리 함으로써 한국의 효 문화의 특성상 환자가 입원 전 가정에 더 오래 머물 수 있도록 하면서도 치매 환자의 부양자들이 갖는 경제적, 신체적, 심리적 부양 부담을 줄일 수 있다. 시스템 내에서 축적된 개인별 데이터베이스는 전문의에게 상담, 치료 가능하며 전문 치료 기관 및 복지 시설과의 연계를 통한 전문 서비스를 지원 받을 수 있다.

주행 데이터 분석을 통한 수소버스 운행안전 모니터링 기법 연구 (Study of Hydrogen Bus Operational Safety Monitoring Method through Driving Data Analysis)

  • 이현미;이인식;이용주;장정아;김시우; 심소정
    • 자동차안전학회지
    • /
    • 제15권4호
    • /
    • pp.58-64
    • /
    • 2023
  • The adoption of hydrogen-powered Elec is expanding globally. Hydrogen is recognized as a potentially hazardous energy source, and safety assessment is crucial for the development of plans to supply hydrogen-powered electric buses. Hydrogen gas leakage can have a significant impact during bus operations, and continuous hydrogen leakage in hydrogen-powered vehicles can result in fatal accidents. In this study, information about hydrogen leakage is collected through sensors installed within the vehicles and is measured when the sensor detects a leak. The study also proposes the use of Pseudo Fuel Leakage (PFL, %) as an additional indicator for evaluating and monitoring hydrogen safety and leakage.