• 제목/요약/키워드: gas insulation

검색결과 539건 처리시간 0.025초

Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.

Carbon Fabric을 삽입한 EPDM계 연소관 내열재 삭마 특성 연구 (Ablation Characteristic Study for Carbon Fabric/EPDM Chamber Insulation)

  • 김진용;최지용;노태호;이원복;조원만;함희철;윤남균;이영우
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.85-91
    • /
    • 2011
  • 본 연구에서는 높은 강도의 가스흐름으로부터 연소실 내부를 보호하기 위하여 carbon fabric을 삽입한 EPDM계 내열재를 개발하였다. 연소관 내열재의 삭마 특성을 시험하기 위하여 6-inch 모사모타에 extension tube를 연결하였고, 모타와 extension tube 사이에 구멍이 있는 FRP를 삽입하여 추진제 연소시 높은 강도의 가스흐름을 유도하였다. 결과적으로 연소시험후 carbon fabric/EPDM 연소관 내열재의 삭마량은 다른 연소관 내열재들에 비해 감소하는 것으로 확인되었다.

  • PDF

Si와 GaAs기판 위에 AIN 박막의 전기적 특성 (Properties Electric of AIN Thin Film on the Si and GaAs Substrate)

  • 박정철;추순남;권정렬;이헌용
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.5-11
    • /
    • 2008
  • To study the effects of $H_2$ gas on AIN insulation thin film, we prepared AIN thin film on Si and GaAs substrate by means of reactive sputtering method using $H_2$ gas as an additives, With treatment conditions of $H_2$ gas AIN thin film shows variable electrical properties such as its crystallization and hysterisis affected to electrical property, As a results, AIN thin film fabricated on Si substrate post-treated with $H_2$ gas for 20 minutes shows much better an insulation property than that of pre-treated, And AIN film treated with $H_2$ gas comparing to non-treated AIN film shows a flat band voltage decreasment. But In GaAs substrate $H_2$ gas does not effect on the flat band voltage.

건조공기의 연면방전에서 가스압력과 극간거리에 따른 매질효과분석 (Analysis of Medium Effect by Gas Pressure and Gap at Surface Discharge of Dry Air)

  • 임동영;민경준;박혜리;최은혁;최상태;배성우;이상봉;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.86-92
    • /
    • 2013
  • In studies on an alternative insulating gas of $SF_6$ gas, the section of the alternative gas and an insulation technique to improve its low dielectric strength have been reported, but very few attempts have been made at the dependence of a gas pressure and a gap as well as the medium effect in the alternative gas. The purpose of this paper is to analyze the dependence of the gas pressure and the gap at surface flashover voltage in dry air. The dependence is analyzed based on the medium effect. The medium effect by the gas pressure and the gap can be explained by surface roughness of a solid dielectric and an electrode as well as an electric field which decreases due to the correlation between the collision ionization coefficient and the gap, respectively. In addition, an insulation technique which can fabricate a compact eco-friendly gas insulated switchgear is proposed by the results of this paper.

열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구 (On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects)

  • 김청균;조승현;서흥석;홍성호;이승림;김영규;권부길
    • 한국가스학회지
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2004
  • 본 연구에서는 멤브레인식 LNG 저장탱크의 누설 안전성을 목재와 PUF로 구성된 단열재 및 예응력 콘크리트(PC) 재질이 균일하다는 가정하에 열저항 평형온도 효과를 고려하여 유한요소법(FEM)으로 해석하였다. FEM 계산결과에 따르면, 목재와 PUF로 구성된 단열재 구조물은 누설 LNG에 의해 구조물 자체가 먼저 파손되므로 누설 안전성을 보장할 수 없다. 그러나, 내부탱크와 단열재가 동시에 파손되어도 외부탱크 PC 구조물은 강도 안전성을 확보하고 있으므로 누설 LNG를 최소 10일 정도는 안전하게 지연시킬 수 있어 멤브레인식 LNG 저장탱크 시스템의 누설 안전성은 확보될 수 있다.

  • PDF

Identification of Partial Discharge Defects based on Back- Propagation Algorithm in Eco-friendly Insulation Gas

  • Sung-Wook Kim
    • Journal of information and communication convergence engineering
    • /
    • 제21권3호
    • /
    • pp.233-238
    • /
    • 2023
  • This study presents a method for identifying partial discharge defects in an eco-friendly gas insulated system using a backpropagation algorithm. Four partial discharge (PD) electrode systems, namely, a free-moving particle, protrusion on the conductor, protrusion on the enclosure, and voids, were designed to simulate PD defects that can occur during the operation of eco-friendly gas-insulated switchgear. The PD signals were measured using an ultrahigh-frequency sensor as a nonconventional method based on IEC 62478. To identify the types of PD defects, the PD parameters of single PD pulses in the time and frequency domains and the phase-resolved partial discharge patterns were extracted, and a back-propagation algorithm in the artificial neural network was designed using a virtual instrument based on LabVIEW. The backpropagation algorithm proposed in this paper has an accuracy rate of over 90% for identifying the types of PD defects, and the result is expected to be used as a reference database for asset management and maintenance work for eco-friendly gas-insulated power equipment.

소듐냉각 고속로의 커버가스 영역에서 열유동 해석 (ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN THE COVER GAS REGION OF SODIUM-COOLED FAST REACTOR)

  • 이태호;김성오;한도희
    • 한국전산유체공학회지
    • /
    • 제13권3호
    • /
    • pp.21-27
    • /
    • 2008
  • The reactor head of a sodium-cooled fast reactor KALIMER-600 should be cooled during the reactor operation in order to maintain the integrity of sealing material and to prevent a creep fatigue. Analyzing turbulent natural convection flow in the cover gas region of reactor vessel with the commercial CFD code CFX10.0, the cooling requirement for the reactor head and the performance of the insulation plate were assessed. The results showed that the high temperature region around reactor vessel was caused by the convective heat transfer of Helium gas flow ascending the gap between the insulation plate and the reactor vessel inner wall. The insulation plate was shown to sufficiently block the radiative heat transfer from pool surface to reactor head to a satisfactory degree. More than $32.5m^3$/sec of cooling air flow rate was predicted to maintain the required temperature of reactor head.

GIS내에서 금속이물이 절연파괴에 미치는 영향 (The Effect of Conducting Particles on Breakdown Phenomena in GIS)

  • 김민규;문인옥;김윤택;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1574-1576
    • /
    • 1994
  • $SF_6$ gas has become an important insulation medium in modern electric power apparatus, because of its high insulation withstand levels and good arc quenching capability. For the application of $SF_6$ gas in GIS the estimation of insulation properties is a fundamental point. Moreover the reduction of withstand levels in case of inhomogeneous fields caused by particles or fixed protrusions is of special interest. It is known that the presence of free conducting particles in GIS can significantly lower the insulating level of $SF_6$ gas at elevated pressure and also it has been recently shown that dielectric strength is greatly reduced by fast transients such as disconnector surges where metallic particles are involved. In this paper, we have disigned the particle test chamber rated 362kV for the purpose of investigating the discharge characteristics in SF6 gas where inhomogenius fields are caused by metallic particles.

  • PDF

기능성 경사 재료의 적용을 통한 진공 인터럽터의 삼중점 전계 완화 (Reduction of the Electric Field Concentration at the Triple Junction of the Vacuum Interrupter by Using the Application of Functionally Graded Material)

  • 최승길;구치욱;주흥진
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.630-635
    • /
    • 2015
  • A vacuum Interrupter (VI), a core part that composes the breaking part of medium-voltage vacuum circuit breaker (VCB), has the excellent insulation performance and arc-extinguishing capability. $SF_6$ gas had been used for the external insulation of VIs since the dielectric strength of $SF_6$ gas is superior to that of other insulation gases. However, because of environmental problems related with global warming, a solid-insulated technology was recently researched. The functionally graded material (FGM), as changing spatially the distribution of the relative permittivity inside an insulator, can reduce the electric field stress at the specific region. Especially, the external insulation performance of the VI with the molded FGM insulator is greatly improved as compared with that of the existing VI or the VI with a new external shield. In this paper, the effectiveness of this FGM insulator is verified by the numerical simulation.

IRMCFC의 연구개발 동향 (Research and Development status of IRMCFC)

  • 김귀열;윤문수;문길호;연제홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.857-859
    • /
    • 1992
  • The molten carbonate fuel cell is a new method for generating power which uses coal gasification gas and reformed liquid natural gas for fuel at very high efficiency and with minimal pollution. The purpose of this research is to investigate principle, properties and research status of internal reforming molten carbonate fuel cell.

  • PDF