• Title/Summary/Keyword: gas insulation

Search Result 539, Processing Time 0.025 seconds

Study on Optimum Design for constitution part of Composite Insulator (Composite Insulator 구성 부품에 대한 최적 설계 연구)

  • Chung, Young-Soo;Choi, Sung-Man;Jang, Yoon-Ki;Lee, Dong-Woen;Kim, Jeong-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1181-1186
    • /
    • 2008
  • Insulators which are used in the domestic electrical industries are mostly depended on importation from some advance countries. Even though insulators which are made of ceramic material have been mostly used domestically, the ratio of usage on composite insulators is recently being increased because of difficulties in manufacturing and high cost regarding ceramic stuffs. In this research, we are trying to develop the composite insulators which are very efficient in insulation regardless of the matter of weight. Even though the technique of manufacturing composite insulator are quite generalized worldwide at the moment, one of the most important issue is to keep security on the know-how that an ingredient of insulated material named 'SF6 gas' is included. Therefore, The aim of this paper is to improve the bonding force and air tight property between two components of composite insulator, Flange and FRP Tube.

  • PDF

The insulation characteristic of $SF_6$ at temperatures (온도변화에 따른 $SF_6$ 가스의 절연특성)

  • Park, K.T.;Park, K.S.;Lee, K.S.;Chio, P.J.;Do, D.H.;Yoon, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1662-1664
    • /
    • 2002
  • 경제성장과 더불어 신뢰성이 높은 양질의 전기에너지의 공급이 필요하게 되었다. 최근에는 고압 $SF_6$가스를 절연매체로 하는 가스절연개폐기(Gas Insulate Switchgear:GIS)설비가 여러 지역에서 건설 운전 중이다. 본 논문은 GIS내의 $SF_6$가스의 온도변화에 따른 절연특성 및 $SF_6$의 액화에 따른 절연특성에 관한 연구이다.

  • PDF

Noise Prediction of HRSG for Gas Turbine (복합발전용 배열회수보일러의 소음예측)

  • 남경훈;박석호;김백영;김원일
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1116-1122
    • /
    • 1999
  • HRSG, which is one of main components of the combined cycle power plant,is composed of an inlet duct, a main body and casing, an outlet duct and a stack. It is important to design HRSG wihtin the allowable noise limit. For this purpose, it is necessary to analyze and predict the noise reduction and radiation at HRSG. In this paper, the technology for the noise prediction at each part of HRSG has been based on the empirical and field data, and also the HRSG noise prediction program has been developed. In order to verify the developed technology and program a field test is conducted. The results of noise prediction show good agreement with the measured.

  • PDF

Comparative Study of Fluidized Bed-type and Assmann Psychrometer (유동층습도계와 아스만습도계의 비교 연구)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

Physical Properties of Inorganic Foam Material for Exterior Fire Resistance Material (무기발포체의 화재확산 방지용 외장재 적용을 위한 물성평가)

  • Shin, Hyeon-Uk;Kim, Ji-hyeon;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.124-125
    • /
    • 2016
  • This study is to development of inorganic insulation material using by-product materials. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials.In this study, cullet and fly ash were used as basic materials in order to secure a recycling technology of by-products which was mostly discarded and reclimed, and measure of physical properties of light-weight ceramic insulator.

  • PDF

A Study on the Analysis of the Lightning Surge Characteristics of Arresters in a 154kV Substation (154kV 변전소에서 피뢰장치의 뇌서지특성 해석)

  • Yun, Chang-Sub;Cho, Han-Goo;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.433-439
    • /
    • 2006
  • This paper describes the characteristic evaluation of 154kV lightning arrester developed by domestic technology. To prove the protective ability of lightning arrester developed, various overvoltages were analyzed for A and B arrester were being used now at 154kV air and gas insulation substation, and for arrester developed. The results obtained by the various simulations show that the developed arrester has the effective protective ability and reducing ability of the overvoltage as A and B arrester, nevertheless there are somewhat differences among three kinds of arresters. Accordingly, it is evaluated that the arrester developed by domestic technology secured reliability can be installed actually at 154kV substation. In this paper, EMTP/ATP was used for simulation.

A analysis result on the PT ferroresonance at 154 kV GIS substation (154 kV GIS의 PT 철공진 소손사례와 원인규명)

  • Woo, J.W.;Shim, E.B.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2076-2079
    • /
    • 1999
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP (Electro-magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

The relation between increment of metallic content arid dielectric characteristics in insulation oil according to degradation of Pole transformer (주상변압기의 열화에 따른 절연유내 금속성분 증가와 절연특성과의 관계)

  • Lee, Dong-Zoon;Kim, Young-Chan;Jung, Yong-Ki;NamGung, Mi-Ok;Yun, Young-Ja;Gwak, Hee-Rho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1746-1748
    • /
    • 1998
  • In this paper, the relation between the increment of metallic content such as copper(Cu) and iron(Fe) according to degradation of pole-transformer oil and change of electrical characteristics according to increment of metallic content was studied. As the result, electrical characteristics was decrease according to increment of metallic content, especially copper content, and the trend of T.C.G(Total Carbonic Gas) agreed with the trend of copper content.

  • PDF

Voltage Time characteristic of electrical breakdown in $SF_6$ ($SF_6$ 가스중 V-t절연파괴특성)

  • Seo, Kil-Soo;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

Cause Analysis of Cone Roof Tank Collapse during Plant Construction (플랜트 공사 중 발생한 Cone Roof Tank 붕괴 사고 원인 분석)

  • Kim, Seung-Han;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • This study is on safety improvement measures through analysis of accident cases during plant storage tank construction. Storage tank is a general term for artificial ground facility constructed to store oil, water, gas, and other chemicals. Some companies have clustered storage tanks (tank farm). The construction methods vary according to the component and types of fluids. Because most of the construction procedures include lifting heavy weight materials using heavy construction equipment and are carried out at high places, storage tank construction contains more risk factors than normal aerial construction. Recently, major accidents such as storage tank collapse have occurred often, and cost many lives due to the characteristics of the structure. In this study we would like to analyze the cause of these accidents and propose measures to improve safety.