• 제목/요약/키워드: gas insulation

검색결과 539건 처리시간 0.026초

코르크 삭마를 고려한 비행체 1D 온도해석 도구 개발 (A Development of One-dimensional Thermal Analysis Tool for Flight Vehicle with Cork Insulation)

  • 정태빈
    • 한국군사과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.464-470
    • /
    • 2018
  • A development of one-dimensional thermal analysis tool is performed to estimate the thickness of cork insulation for flight vehicle. In the calculation of cork temperature, the cork density model, heat of ablation and pyrolysis gas enthalpy model were applied. The calculation for the two-layer model of cork and metal was performed by the tool and compared with the experimental data. The results for the two aerodynamic heating conditions were 17 % and -12 % different from the experimental data, respectively. The effect of mechanical ablation not included in the calculation can be expected as the cause of the difference. The temperature-density curve of cork which adjusted by experimental data was also presented.

공간회로망법을 이용한 GIS내의 움직이는 도체이물질에 대한 전자계 해석 (Analysis of Electromagnetic Field by moving metal particle in GIS using SNM)

  • 임영환;박경수;최영환;최성열;고영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1670-1672
    • /
    • 2001
  • In compared with air insulated switchgear GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high voltage equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when metal particles are moving fast.

  • PDF

셀룰로오스 단열재의 연기발생에 관한 연구 (Studies of the Smoke Emission from Cellulose Fiber Insulation)

  • 김홍;강영구
    • 한국안전학회지
    • /
    • 제9권2호
    • /
    • pp.12-17
    • /
    • 1994
  • Smoke evolved from burning cellulose insulation treated with boric acid-borax-alum as combustion retardants has been studied using a light absorption method. It has been shown that the quantity of smoke are decreased with the increase of oxygen concentration. Applied fire retardants did not increase smoke generation from investigated cellulose insulation in range of themal degradation without flaming. These same fire retardants increased from in the range of flaming combustion. The results of this work have been analysed using imperical equation, which correlated the smoke density at oxygen content of combustion transition. This equation may be. $\sigma$=$\sigma$$_{T}$ exp{-7.24$\times$10$^{-7}$ ( $O_2$ $O_{2.T}$)}Where $O_2$is the concentration of oxygen in the oxidizing gas, and $O_{2.T}$ refers to oxygen concentration of combustion transition.n.n.n.

  • PDF

GIS 내부의 도체이물질에 의한 불평등 전계 해석 (Analysis of unequal electric field by metal particle in GiS)

  • 박경수;김진;이희복;고영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.531-533
    • /
    • 2000
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence So the transformer substation can be reduced the size to 1/10. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high pressure equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when the spacer is bonded and metal particles are moving fast.

  • PDF

변압기 절연유의 열화에 따른 대전특성 (Characteristics of Static Electrification on Insulation Oil Aging)

  • 권동진;김한상;정용기;김경화;김두석;곽희로;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1615-1618
    • /
    • 1994
  • This paper studied the streaming electrification of the U.H.V. transformer with the spinning cylinder system, and compared and analyzed it with the conventional forced flowing system which uses a pump or gas for oil flowing. Also, accumulated surface voltage in its electrified material was measured with the electrostatic voltmeter, and the effect of insulation oil aging was measured. As results, in spinning cylinder system, characteristics of the streaming electrification to its rotational speed and oil temperature are same tendency as those of tile forced flowing system and it showed the spinning cylinder system is useful to study the streaming electrification. And, aging of insulation oil increases the electricity of streaming electrification at initial stage of aging.

  • PDF

공기공급 시스템에 적응되는 Vortex Tube의 에너지 분리특성에 관한 연구(II) -표면의 단열효과에 따른 영향- (A Study for Energy Separation of Vortex Tube Using Air Supply System(II) - the effect of surface insulation -)

  • 방창훈;추홍록;유갑종
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.3-9
    • /
    • 1999
  • The vortex tube is a simple device which splits a compressed gas stream into a cold stream and a hot stream without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. In this study, the insulation effect of surface on the efficiency of vortex tube was performed experimentally. The experiment is carried out for nozzle area ratio of 0.194, diameter ratio of cold end orifice of 0.6 and input pressure ranging from 0.2Mpa to 0.5Mpa. The purpose of this study is focused on the effect of surface insulation of vortex tube with the variation of cold air mass flow ratio. The results indicate that the temperature difference of cold and hot air are higher about 12% and 30% than that of not insulated vortex tube respectively. Furthermore, for the insulated vortex tube, the similarity relation for the prediction of cold end temperature as the function of cold air mass flow ratio and input pressure is obtained.

  • PDF

공간회로망법을 이용한 GIS 내부의 움직이는 도체이물질에 의한 불평등전계 해석 (Analysis of Unequal Electric Field by Moving Metal Particle in GIS Using SNM)

  • 박경수;최성열;고영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.68-73
    • /
    • 2002
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristic for high voltage equipment but has a characteristic that insulation heredity is changed for internal unequal electric field. So analysis of time varying electromagnetic field in GIS is very important for structure design and trouble diagnosis process. In compared with established method, the SNM(Spatial Network Method) in this Paper can observe variation of electromagnetic field with real time and get result very similar to measurement. In order to Know variation of electromagnetic field distribution in fast moving particle, we make used of SNM.

동물성 기포제의 희석농도에 따른 기포콘크리트의 특성 (Properties of Foamed Concrete according to Dilution Concentrations of Animality Protein Foaming Agent)

  • 임정준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.77-78
    • /
    • 2019
  • Organic insulating materials can cause fatal toxic gases when burned, which can lead to human injury. As a combustible material, the risk of fire spreading is great. Therefore, there is a need for a study on the lightweight cured body for the non-combustible inorganic insulation to replace the flammable organic insulation. This study aims to examine the properties of lightweight foamed concrete according to the dilution concentration of animal foaming agent which forms a closed void when foaming as a part of the experiment to examine the utility of the lightweight foamed concrete as an insulating material. Bubbles occupy a large volume of lightweight foam concrete and have a great influence on the properties. Therefore, the stability of the bubble is very important, and as a result of the experiment, it is determined that 3% of the smallest vesicles are prepared at the proper dilution concentration.

  • PDF

단열성능향상 재료를 사용한 콘크리트의 열전도 특성에 관한 연구 (Study on the Thermal Conduction of Concrete using Insulation Performance Improvement Materials)

  • 김정호;박영신;김상헌;전현규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.280-281
    • /
    • 2014
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. Therefore, various actions to reduce greenhouse gas and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. But a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research is structural insulation concrete what improved insulation performance using micro form admixture and calcined diatomite powder and lightweight aggregate.

  • PDF

Breakdown Characteristics of Insulation Materials for a Termination of Power Transmission Class HTS Cable

  • Kwag Dong-Soon;Cheon Hyeon-Gweon;Choi Jae-Hyeong;Kim Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.37-42
    • /
    • 2006
  • A research on several characteristics such as volume breakdown and surface discharge of insulators for a termination of power transmission class HTS cable was performed. We investigated the surface discharge of glass fiber reinforced plastic (GFRP) under air, cryogenic nitrogen gas and nitrogen gas media. The breakdown characteristics of these media were studied. Experimental results revealed that flashover voltage greatly depends on pressure, temperature, the kinds of insulating media and voltages, but it is slightly affected by shape and material of electrode. The breakdown voltage of liquid nitrogen, cryogenic nitrogen gas and nitrogen gas deeply depends on the shape and dimension of electrode, kinds of voltages and pressure. Moreover, the breakdown voltage of cryogenic nitrogen gas and flashover voltage of GFRP in the cryogenic nitrogen gas is also influenced by temperature and vapour-mist density of the gas.