• 제목/요약/키워드: gas generation rate

검색결과 355건 처리시간 0.024초

발전소 절탄기 튜브의 배기가스 온도와 황산 농도에 따른 노점 및 내식성 분석 (Analysis of dew point and corrosion resistance for power plant economizer tube with exhaust gas temperature and sulfuric acid concentration)

  • 최재훈;이승준
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.433-440
    • /
    • 2022
  • Environmental pollution caused by power plant exhaust gas is highlighted and eco-friendly regulations are being strengthened. However, due to the abundant reserves and low prices of coal, still the most used for power generation in the world. Therefore, flexible operation of coal-fired power plants to reduce emissions has become an inevitable option. However, lowering the output increases the possibility of acid dew point corrosion as the exhaust gas temperature decreases. The dew point corrosion occurs when condensable gases such as SO3, HCl, NO2 and H2O cools below the saturation temperature. SO3 is already well known to cause severe low- temperature corrosion in coal-fired power plants. Therefore, this study aims to prevent damage that may occur during operation by analyzing the dew point and corrosion resistance with exhaust gas temperature and sulfuric acid concentration of the power plant economizer tube.

Packed-bed type 반응기에서 $NO_x$제거에 대한 Pellet의 영향 (The effect of Pellet about $DeNO_x$ for Packed-bed type reactor)

  • 박재윤;이경호;이동훈;김정달;박상헌;고희석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.203-206
    • /
    • 2000
  • In this experiment, an attempt to use pellets($BaTiO_3$, $TiO_2$, ${\gamma}-Al_2O_3$, sludge) for $NO_x$ removal was conducted The effect of pellets on NO removal from simulated flue gas was experimentally investigated for packed-bed reactor of plate-plate geometry. An experimental investigation has been conducted for NO concentration of 50ppm balanced by air, and gas flow rate of $5{\ell}/min$. Ceramic pellets were used for surface discharge and the sludge pellets was added on $BaTiO_3$ and $TiO_2$ to increase $NO_x$ removal rate. In the result, $NO_x$ removal rate using $TiO_2$ was better than other pellets. $NO_2$ segnificatly generated by using $BaTiO_3$ pellets and sludge pellets used with $BaTiO_3$ decreased $NO_2$ generation.

  • PDF

초단열 압축스파크 점화개질기를 이용한 바이오 합성가스 생산 연구 (Research of Biofuel Syngas Production Using Superadiabatic Compression Spark Ignition Reformer)

  • 임문섭;전영남
    • 한국수소및신에너지학회논문집
    • /
    • 제21권1호
    • /
    • pp.42-49
    • /
    • 2010
  • Increasing environmental concerns regarding the use of fossil fuels and global wanning have prompted researcher to investigate alternative fuels. The purpose of this study is to investigate the syngas production by biogas reforming using a compression spark ignition engine. The parametric screening studies were carried out according to the variations of oxygen enrichment rate, biogas $CO_2$ ratio, intake gas temperature, and engine revolution. When the oxygen enrichment rate and input gas temperature increased, hydrogen and carbon monoxide were increased. But the biogas $CO_2$ ratio and engine revolution increased, the syngas were reduced. For the reforming of methane 100% only, generation of hydrogen and carbon monoxide was 58% and 17%, respectively. However when the biogas $CO_2$ ratio was 40%, hydrogen and carbon monoxide concentration were about 20% each.

유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구 (A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration)

  • 박진엽;진수환;박인규
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

공기유량에 따른 글로우 방전의 제전 특성 (Ionizing Characteristic of Glow Discharge by Controlled Air Flow Rate)

  • 최상원
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.49-53
    • /
    • 2008
  • Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. And more, ionizer was developed recently using an atmospheric pressure glow discharge. On the other hand, ionizer needs a compressed or blown air to transport ion for charged objects. This air is very useful in explosive hazardous area to prevent the explosion of flammable gas and/or vapor by ignition sources, e.g. electrical spark. In this paper, we investigated the ionizing characteristic of atmospheric pressure glow discharge by controlled air flow rate from 5 liters to 60 liters a minute, and compared with decay time between the corona discharge and glow discharge as a function of some direction and distance from discharge ion source. We confirmed that an air flow rate needs 25 liters a minute to sustain the most suitable atmospheric pressure glow discharge and to increase an ionizing efficiency.

기-액 혼합 플라즈마 방전 시스템에서 화학적 활성종의 생성 (Study on the Generation of Chemically Active Species Using Gas-liquid Mixing Plasma Discharging System)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제30권4호
    • /
    • pp.394-402
    • /
    • 2014
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and oxygen flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the 2nd voltage (4 kV to 15 kV) was increase, RNO degradation was increased and, generated $H_2O_2$ and $O_3$ concentration were increased. The conductivity of the solution was not influencing the RNO degradation, $H_2O_2$ and $O_3$ generation. The pH effect on RNO degradation was not high. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가 (Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

가스터빈 엔진의 장착성능 해석을 위한 흡입구 2D 모델링에 관한 연구 (A Study on 2D Modelling of Gas Turbine Engine Intake for Installed Performance Analysis)

  • 공창덕;고성희;기자영;전용민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.335-338
    • /
    • 2007
  • 본 연구에서는 항공기 추진기관의 정확한 장착 성능해석 시 고려하여 할 주요 장착 손실 중 흡입구의 압력 손실을 계산하기 위해 2D 모델링을 수행하였으며 해석 결과를 이용하여 비행마하수와 유량에 따른 흡입구 압력손실 값을 나타낸 0D 성능 맵을 생성하였다. 이러한 성능 맵 생성 절차의 타당성을 검증하기 위해 일반적인 항공기용 엔진 흡입구 형상에 적용하여 타당성을 확인하였다.

  • PDF

발전용 대형 엔진 적용을 위한 천연가스-디젤 혼소에 대한 수치 해석적 연구 (Numerical Study on Co-Combustion in Diesel Engine for Heavy-Duty Power Generation)

  • 서동균;허광범;정연태;김의현
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.369-376
    • /
    • 2015
  • Recently KEPCO, KOGAS and other institutions are jointly conducting an R&D for the development and demonstration of the power generation system based on a natural gas/diesel engine on an island. As a preliminary study, co-combustion in the dual fuel engine, which is expected to produce a few mega-watts of electricity, was modeled and calculated using computational fluid dynamics (CFD). The applied key assumptions are 2-dimensional axisymmetric, transient and static volume chemical reaction. Based on the selected blending ratio, which is the key operating condition, natural gas is substituted instead of diesel fuel (basis of high heating value). Results showed that as the blending ratio increases, the reaction rate of the combustion increases and thus maximum temperature is reached more rapidly. For the optimal performance, various geometric or operational studies will further be conducted.

Prediction of greenhouse gas emission from municipal solid waste for South Korea

  • Popli, Kanchan;Lim, Jeejae;Kim, Hyeon Kyeong;Kim, Young Min;Tuu, Nguyen Thanh;Kim, Seungdo
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.462-469
    • /
    • 2020
  • This study is proposing a System Dynamics Model for estimating Greenhouse Gas (GHG) emission from treating Municipal Solid Waste (MSW) in South Korea for years 2000 to 2030. The government of country decided to decrease the total GHG emission from waste sector in 2030 as per Business-as-usual level. In context, four scenarios are generated to predict GHG emission from treating the MSW with three processes i.e., landfill, incineration and recycling. For prior step, MSW generation rate is projected for present and future case using population and waste generation per capita data. It is found that population and total MSW are directly correlated. The total population will increase to 56.27 million and total MSW will be 21.59 million tons in 2030. The methods for estimating GHG emission from landfill, incineration and recycling are adopted from IPCC, 2006 guidelines. The study indicates that Scenario 2 is best to adopt for decreasing the total GHG emission in future where recycling waste is increased to 75% and landfill waste is decreased to 7.6%. Lastly, it is concluded that choosing proper method for treating the MSW in country can result into savings of GHG emission.