• Title/Summary/Keyword: gas explosion simulation

Search Result 54, Processing Time 0.028 seconds

Review on the Process Safety of $SiH_{4}$ Gas used in Semiconductor and FPD Field (반도체 및 FPD 분야에 사용되는 $SiH_{4}$ 가스의 공정 안전 고찰)

  • Kim, Joung-Cho;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.32-36
    • /
    • 2007
  • When the vacuum system for the process of $SiH_{4}$ gas used in the semiconductor and FPD field is partially vented from vacuum to atmospheric state, a fire often occurs due to auto-ignition of $SiH_{4}$ gas. In order to prevent the fire, the concentration of $SiH_{4}$ should be kept under LFL. This means that the higher capacity pump is needed to meet the process conditions as well as the condition that the concentration of $SiH_{4}$ should be kept under LFL. In this article, we conducted the injection of the dilution gas at the manifold between booster pump and dry pump compared with the typical method that the dilution gas was injected into inlet port of booster pump using computer simulation. According to the result, we can flow further more purge gas for safety without any change of the condition in the process chamber, which means that the higher capacity pump is not required for safety in some cases.

Numerical Study of Fire Behavior Induced by Gas Leakage in Combined Cycle Power Plant (복합발전플랜트 내의 가스 화재 거동에 관한 수치해석)

  • Park, Jaeyong;Sung, Kunhyuk;Li, Longnan;Choi, Jinwook;Kim, Daejoong;Lee, Seong Hyuk;Ryou, Hong Sun
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • To date, the demand for Combined Cycle Power Plant (CCPP) has been continuously increased to overcome the problem of air pollution and lack of energy. In particular, the underground CCPP is exposed to substantial fire and explosion risks induced by gas leakage. The present study conducted numerical simulations to examine the fire behavior and gas leakage characteristics for a restricted region including gas turbine and other components used in a typical CCPP system. The commercial code of FLUENT V.14 was used for simulation. From the results, it was found that flammable limit distribution of leakage gas affects fire behavior. Especially, the flame is propagated in an instant in restricted region with LNG gas. In addition, consequence analysis factors such as critical temperature and radiation heat flux are introduced. These results would be useful in making the safety guidelines for the underground CCPP.

Simulation and Process Optimization of High Energetic Materials Demilitarization Facility Gas Treatment Process (고에너지물질 비군사화 시설의 후처리 공정 모사 및 열교환기 합성망을 이용한 에너지 최적화)

  • Hwang, Raymoon;Kim, Hyounsoo;Oh, Min;Moon, Il
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.79-83
    • /
    • 2021
  • The expiration date of high energetic materials(HEM), such as HMX, RDX, TNT, is important. If the expiration date is violated, the expected specification of HEM would not be satisfied which may cause a different conclusion in an urgent situation. As a result, this HEM should maintain fresh conditions which cause the accumulation of waste HEM. If HEM is landfilled during demilitarization, the impact on living organizations is serious. Additionally, landfilling HEM has a possibility of explosion. In this research, the process flow diagram of the demilitarization gas treatment process was simulated while satisfying the law of the environment in Korea. After validation of simulation, it was optimized thermodynamically using Heat Exchanger Network Synthesis(HENs). This study is expected to enhance the energy efficiency of the original facility by suggesting developed designs. This research was supported by Agency of Defense Development NE32 Korea. Thanks to Agency of Defense Development, Korea

Regulation of Star Formation in Turbulent, Multiphase Interstellar Media

  • Kim, Chang-Goo;Kim, Woong-Tae;Ostriker, Eve C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.66.1-66.1
    • /
    • 2010
  • Using two-dimensional numerical hydrodynamic simulations, we investigate the star formation rate (SFR) in turbulent, multiphase, galactic gaseous disks. Our simulation domain is axisymmetric, and local in the radial direction and global in the vertical direction. Our models include galactic rotation, vertical density stratification, self-gravity, radiative heating and cooling, and thermal conduction, but do not include spiral-arm features. Turbulence in our models is driven by momentum feedback from supernova explosion events occurring in localized dense regions formed by thermal and gravitational instabilities. Self-consistent radiative heating, representing enhanced/reduced FUV photons from the star formation, is also taken into account. By controlling three parameters (the gas surface density, the stellar disk density, and the angular rotation rate) that characterize local galactic disks, we explore how the SFR depends on the background environmental state. We also discuss the relation between the SFR and the gas surface density found in our numerical models in comparison with observations.

  • PDF

3D Explosion Analyses of Hydrogen Refueling Station Structure Using Portable LiDAR Scanner and AUTODYN (휴대형 라이다 스캐너와 AUTODYN를 이용한 수소 충전소 구조물의 3차원 폭발해석)

  • Baluch, Khaqan;Shin, Chanhwi;Cho, Yongdon;Cho, Sangho
    • Explosives and Blasting
    • /
    • v.40 no.3
    • /
    • pp.19-32
    • /
    • 2022
  • Hydrogen is a fuel having the highest energy compared with other common fuels. This means hydrogen is a clean energy source for the future. However, using hydrogen as a fuel has implication regarding carrier and storage issues, as hydrogen is highly inflammable and unstable gas susceptible to explosion. Explosions resulting from hydrogen-air mixtures have already been encountered and well documented in research experiments. However, there are still large gaps in this research field as the use of numerical tools and field experiments are required to fully understand the safety measures necessary to prevent hydrogen explosions. The purpose of this present study is to develop and simulate 3D numerical modelling of an existing hydrogen gas station in Jeonju by using handheld LiDAR and Ansys AUTODYN, as well as the processing of point cloud scans and use of cloud dataset to develop FEM 3D meshed model for the numerical simulation to predict peak-over pressures. The results show that the Lidar scanning technique combined with the ANSYS AUTODYN can help to determine the safety distance and as well as construct, simulate and predict the peak over-pressures for hydrogen refueling station explosions.

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

Application of Fuzzy Logic for Predicting of Mine Fire in Underground Coal Mine

  • Danish, Esmatullah;Onder, Mustafa
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.322-334
    • /
    • 2020
  • Background: Spontaneous combustion of coal is one of the factors which causes direct or indirect gas and dust explosion, mine fire, the release of toxic gases, loss of reserve, and loss of miners' life. To avoid these incidents, the prediction of spontaneous combustion is essential. The safety of miner's in the mining field can be assured if the prediction of a coal fire is carried out at an early stage. Method: Adularya Underground Coal Mine which is fully mechanized with longwall mining method was selected as a case study area. The data collected for 2017, by sensors from ten gas monitoring stations were used for the simulation and prediction of a coal fire. In this study, the fuzzy logic model is used because of the uncertainties, nonlinearity, and imprecise variables in the data. For coal fire prediction, CO, O2, N2, and temperature were used as input variables whereas fire intensity was considered as the output variable.The simulation of the model is carried out using the Mamdani inference system and run by the Fuzzy Logic Toolbox in MATLAB. Results: The results showed that the fuzzy logic system is more reliable in predicting fire intensity with respect to uncertainties and nonlinearities of the data. It also indicates that the 1409 and 610/2B gas station points have a greater chance of causing spontaneous combustion and therefore require a precautional measure. Conclusion: The fuzzy logic model shows higher probability in predicting fire intensity with the simultaneous application of many variables compared with Graham's index.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

A study of sub-galactic scale structure formation with a cosmological hydro code

  • Shin, Ji-Hye;Kim, Ju-Han;Kim, Sung-Soo S.;Yoon, Suk-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.57.2-57.2
    • /
    • 2011
  • To study the formation and evolution of sub-galactic scale structures, we have added SPH (Smoothed Particle Hydrodynamics) method into an existing cosmological PMTree code, GOTPM. To follow the evolution of gas particles, we consider heating/cooling processes, star formation, and energy & metal feedback by supernova explosion. We have performed various tests for the new code and found that the results reproduce observed quantities or follow the known analytic solutions. We present a test simulation of isolated disk galaxy with a focus on whether the star formation reproduces the observed features.

  • PDF

A Study on Ventilation Characteristics of LNG Carrier Hood room by PIV and CFD (PIV와 CFD에 의한 LNG선박의 Hood room 환기특성에 관한 연구)

  • Cho, D.H.;Kim, D.C.;Kim, M.E.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.673-679
    • /
    • 2000
  • LNG Carriers are currently known as sole commercial means of shipping natural gas on the sea. They are designed to proven dangerous explosion for shipping a lot of gas over long distance. In this study. In this study, a scaled model chamber was made to investigate ventilation characteristics of the hood room in LNG carrier. Experimental study was performed in model using visualization equipments with laser apparatus and image intensifier CCD camera gated by an AOM controller Twelve different kinds of measuring area were selected as experimental condition. Instant simultaneous velocity vectors at whole field were measured by using 2-D PIV system which software adopts two-frame grey-level cross correlation algorithm. To look into stagnation area of hood room for LNG carrier, a three-dimensional numerical simulation with standard ${\kappa}-{\varepsilon}$ model was carried out by using PHOENICS for three kinds of Reynolds number, $6.5{\times}10^3$, $9.7{\times}10^3\;and\;1.29{\times}10^4$, based on the cavity inlet velocity and cavity height. The flow pattern showed the large scale counter-clockwise forced-vortex rotated at center area, small eddies at each corner and stagnation area located at left-back upper side of model.

  • PDF