• 제목/요약/키워드: gas cooling

검색결과 1,095건 처리시간 0.025초

제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구 (A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building)

  • 성욱주;임민엽;김석현;조수
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

Thermal stability, magnetic and magnetocaloric properties of Gd55Co35M10 (M = Si, Zr and Nb) melt-spun ribbons

  • Jiao, D.L.;Zhong, X.C.;Zhang, H.;Qiu, W.Q.;Liu, Z.W.;Ramanujan, R.V.
    • Current Applied Physics
    • /
    • 제18권12호
    • /
    • pp.1523-1527
    • /
    • 2018
  • The thermal stability, magnetic and magnetocaloric properties of $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) melts-pun ribbons were studied. The relatively high reduced glass transition temperature ($T_{x1}/T_m$ > 0.60) and low melting point ($T_m$) resulted in excellent glass forming ability (GFA). The Curie temperatures ($T_C$) of melt-spun amorphous ribbons $Gd_{55}Co_{35}M_{10}$ for M = Si, Zr and Nb were 166, 148 and 173 K, respectively. For a magnetic field change of 2 T, the values of maximum magnetic entropy change $(-{\Delta}S_M)^{max}$ for $Gd_{55}Co_{35}Si_{10}$, $Gd_{55}Co_{35}Zr_{10}$ and $Gd_{55}Co_{35}Nb_{10}$ were found to be 2.86, 4.28 and $4.05J\;kg^{-1}K^{-1}$, while the refrigeration capacity (RC) values were 154, 274 and $174J\;kg^{-1}$, respectively. The $RC_{FWHM}$ values of amorphous alloys $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) are comparable to or larger than that of $LaFe_{11.6}Si_{1.4}$ crystalline alloy. Large values of $(-{\Delta}S_M)^{max}$ and RC along with good thermal stability make $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) amorphous alloys be potential materials for magnetic cooling operating in a wide temperature range from 150 to 175 K, e.g., as part of a gas liquefaction process.

하이브리드 발전 시스템을 적용한 이동식 하우스 (Transportable House with Hybrid Power Generation System)

  • 박미정;주종율;김응곤
    • 한국전자통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.205-212
    • /
    • 2023
  • 현대사회는 화석연료 등의 사용으로 기후변화로 인한 기상이변이 전 세계가 이례적인 피해가 속출하고, 코로나와 같은 전염병이 인간에게 더욱 생활의 질이 악화되고 있는 실정이다. 온실가스를 줄이고 신재생에너지 사용이 시급한 현실이다. 화석연료의 사용을 줄이고 신재생에너지 사용으로 지구환경 오염을 줄이고자 한다. 본 논문에서는 태양광을 이용해 지능형 CCTV 및 인터넷 WiFi, 냉난방 시스템을 통한 사계절 환경과 안전 및 통신 기능이 가능하고, 스마트폰 앱을 통한 태양광의 생산량과 소비량을 실시간으로 모니터링하여 최적화된 전력관리를 할 수 있는 시스템을 제안한다. 태양광 발전 시스템을 사용할 수 없는 한파, 태풍, 자연재해 등의 계통 정전과 같은 비상시 끊김 없는 디젤 발전을 지원하는 하이브리드 발전시스템을 제안한다.

2 스풀 혼합흐름 배기방식 터보팬 엔진 성능해석 모델링 (Two Spool Mixed-Flow Turbofan Engine Performance Analysis Modeling)

  • 이승헌;이형진;김상조;나규진;김중회
    • 한국추진공학회지
    • /
    • 제27권1호
    • /
    • pp.37-48
    • /
    • 2023
  • 본 연구에서는 정상 상태 및 천이 상태에 따른 항공기용 터보팬 엔진의 성능해석 모델링을 수행하였다. 대상 엔진은 Pratt & Whitney 사의 F100-PW-229으로 선정하여 팬, 고압 압축기, 연소기, 고압터빈, 저압 터빈, Mixer, 수축-확산형 노즐 등의 구성품을 모델링하였다. 또한, 이차 유로를 통한 터빈에서의 냉각 효과를 적용하였다. Simulink를 이용하여 터보팬 엔진 성능해석 프로그램을 자체 개발함에 따라 해석의 자유도가 높으며, 엔진 제어기 설계에 활용이 용이한 구성의 성능해석 프로그램을 개발하였다. 개발된 성능해석 프로그램은 상용 프로그램인 GASTURB 해석 결과와의 비교를 통하여 검증하였다.

몇 가지 냉매를 사용한 이산화탄소 액화에 대한 비교 연구 (Comparative Research on the Carbon Dioxide Liquefaction Using Several Refrigerants)

  • 박일수;황필성;정기철;안준수;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.226-233
    • /
    • 2023
  • In this study, we compared the performance of several refrigeration cycles using different refrigerants and utilizing the cold heat of liquefied natural gas (LNG) for the liquefaction of carbon dioxide. The final conditions for the liquefied CO2 were set to -20℃ and 20 bar. The refrigerants used included R404a, ammonia, propane, and propylene using a vapor recompression refrigeration cycle. For the refrigeration cycle, the CO2 at room temperature and pressure was compressed in a two-stage compression process with an intermediate cooling stage using a refrigeration unit. To compare with the liquefaction process using refrigeration, we compressed the CO2 to 8 bar in a single compression stage and cooled it to around -50℃ using the cold heat of the LNG before liquefying it. Results showed that using ammonia as the refrigerant required the least amount of compressor power for the liquefaction process, and the heat transfer area of the evaporator was the smallest when using propylene as the refrigerant. Using the cold heat of LNG instead of refrigeration using R404a resulted in approximately 69% less energy consumption.

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • 제14권2호
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

액체수소 저장탱크의 냉각 방법 분석 (Analysis of Cool-down Operation of Liquid Hydrogen Tank )

  • 유화롱;최병일;도규형;김태훈;김창현;김민창;한용식
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.641-649
    • /
    • 2023
  • This study analyzes the cool-down process of liquid hydrogen storage tanks, which have advantages in terms of large-capacity transfer, storage, and utilization as hydrogen demand increases. A hydrogen liquefaction plant is selected for analysis and an efficient tank cooling method is sought by comparing the time required for the cool-down process with the gas consumption in connection with the gassing-up process required for the operation of the liquid hydrogen storage tank. The results of this study can be referred to in the operation process after the initial start-up and maintenance of the hydrogen liquefaction plant.

열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구 (A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation)

  • 임용훈;이재용;정모
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제1권3호
    • /
    • pp.143-150
    • /
    • 2012
  • 본 연구에서는 스마트 열 그리드의 운영 특성 분석을 위한 기초적인 방법론과 해당 방법론에 근거한 열 그리드 연계운전 분석 시뮬레이션 프로그램에 대해 소개하고자 하며, 특히 기존의 광역 열에너지네트워크에 해당하는 집단에너지 시스템 인근에 소규모 열 그리드가 신규로 연계되어 운전될 경우에 대한 각 시스템별 운영특성 및 주요 운전 변수에 대한 상호 영향에 대해 면밀히 살펴볼 수 있는 시뮬레이션 방법론에 대해 고찰해보고자 한다. 본 연구에서 열 그리드 간 연계운전에 따른 기존의 규모가 큰 열 그리드에 대한 영향은 해당 그리드의 연간 시각별 운영 실적 데이터를 바탕으로 한 경험적 상관관계식을 도출하여 간략히 모델링하고자 하였으며, 신규 그리드에 설치, 운영되는 열원 설비들에 대한 운전 특성은 실제 제품의 운전부하별 운전효율 자료에 대한 DB를 구축, 사용함으로서 시뮬레이션 분석 결과의 신뢰도를 제고하고자 하였다. 또한 본 시뮬레이션 프로그램에서는 해당 수요처의 에너지부하 예측에 있어 건물 유형별로 연간, 시각별로 실측한 데이터를 기반으로 수립된 단위 에너지부하 모델을 이용, 예측함으로써 운전시뮬레이션을 통한 최적화 분석 결과의 신뢰성을 확보하고자 하였다. 본 연구에서 기 제안된 방법론 및 이에 근거한 시뮬레이션 분석 결과로부터 그리드 상호간 열 거래에 기반한 복수의 열 그리드 운전 특성 분석 방법의 효용성을 확인할 수 있었으며, 향후 수요자 및 열 에너지 공급자간 다양한 정보의 공유를 근간으로 하는 IT 기반 스마트 열 그리드 최적화 분석으로의 확장을 위한 기초 자료를 확보할 수 있었다.

옥천대 남서부지역에 분포하는 화강암류의$^{40}Ar/^{39}Ar$ 각섬석-백운모 연령에 대한 지구조적 의미 (Tectonic Implication of 40Ar/39Ar Hornblende and Muscovite Ages for Granitic Rocks in Southwestern Region of Ogcheon Belt, South Korea)

  • 김용준;박재봉;박영석
    • 암석학회지
    • /
    • 제7권2호
    • /
    • pp.69-76
    • /
    • 1998
  • 옥천대 남서부지역에 분포하는 화강편마암과 광주화강암에서 분리한 각섬석과 백운모의 40Ar/39Ar 분석자료는 다음과 같은 지구조적 의미를 가진다. 이들 시료의 40Ar/39Ar 분석치는 모두 뚜렷한 연령 스펙트럼을 보이며 특히 방출된 39Ar 가스의 60% 이상으로 만들어진 37Arca/39Ark과 38Arcl/39Ark 프라토우(plateau)가 뚜렷하다. 각섬석에 대한 36Ar/40Ar 대 39Ar/40Ar 의 대비도는 시료 HN-100을 제외하고는 모두 뚜렷한 연령 프라토우를 보여준다. 고온단계에서 37Arca/39Ark 값은 38Arcl/39Ark 값의 상대적인 증가에 따른 불규칙성은 판상광물 사이에 들어있던 알곤 가스의 방출에 의한 것으로 추정된다. HN-100은 40Ar/39Ar 전체 알곤가스 연령이 918 Ma로서 저온단계에서 알곤 방출이 있었고 고온단계에서 1360 Ma를 보인다. 전자는 대보운동에 의한 영향을 받은 시기이며, 후자는 선캠브리아기 화강편마암에 포획된 각섬석 결정이 폐쇄온도(약 $500\pm$$50^{\circ}C$)에 도달한 시기를 보여준다. 광주화강암류의 세 암상(각섬석 흑운모 화강섬록암, 흑운모 화강섬록암과 복운모 화강암)이 보이는 165 Ma를 전후한 연령은 저온단계에서 얼마간의 알곤가스 방출이 있었으며 또 기발표된 Rb/Sr 전암년령과 비교하여 젊은 년령을 보이는 것으로 미루어 이 시기는 대보운동의 영향을 받은 시기로 생각된다. 이들 40Ar/39Ar 광물년령과 기발표된 Rb/Sr 전암년령 및 K/Ar 광물년령은 옥천대 남서부지역이 100~150 m/m.y.의 느린 속도로 그리고 산이반도 지역은 100 m/m.y. 이하의 보다 느린 속도로 상승했음을 알려준다. 이 지역에서 가장 강력했던 지각변동 또는 화성활동은 원생대 중기(1360 Ma 전후)와 중생대 쥬라기 중기(약 165 Ma 전후)에 있었다.

  • PDF

모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발 (Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste)

  • 최종서;유영환;박승철;최석모;황태원;신상운
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.110-120
    • /
    • 2005
  • ${\cdot}$저준위 고체폐기물의 유리고화처리 적용연구를 위하여, 현대모비스는 원자력환경기술원 및 프랑스 SGN사와 공동으로 99년 10월에 유리화 실증설비를 건설한 바 있다. 실증설비를 활용하여 모의핵종(Co, Cs)을 포함한 비방사성 이온교환수지, 잡고체 등에 대한 70여 회 이상의 실증시험 수행을 통하여, 대상폐기물을 안전하고 효과적으로 처리할 수 있음을 확인하였다. 그러나 처리공정 중 고온세라믹필터계통(High Temperature Filter : HTF)에서 발생하는 분진의 처리가 문제점으로 도출되었다. 또한 저온용융로(Cold Crucible Melter : CCM)와 HTF를 연결하는 냉각파이프는 장기간 운전시 CCM으로부터 발생한 분진이 침적되어 배관막힘의 우려가 있다. 이와 관련, 기 개발한 유리화공정에 추가하여 HTF에서 발생한 분진을 재순환하는 장치와 냉각파이프 내 침적분진을 제거하는 장치를 개발하였다. 유리화공정 중 HTF에서 발생하는 분진의 처리는 유리화설비의 감용비, 처분비용 및 유리용탕의 조절 측면에서 특히 중요하다. 분진재순환장치(Dust Recycling System : DRS)의 개념은, HTF 하단부에서 발생분진을 수거, 물과 섞어 슬러리 형태로 제조, 이송하여 CCM 내로 다시 투입함으로써 분진을 처리할 수 있도록 하였다. DRS의 주 기능은 분진 내의 모의핵종 및 주요 유리성분을 다시 CCM으로 재순환 처리하는 것이며, 이에 따라 유리용탕의 성분을 일정하게 유지하고 또한 유리배출을 용이하게 하는 데 기여한다. 또한 시멘트 고화설비 등과 같은 별도의 분진처리설비를 고려할 필요가 없다. 제진장치는 주기적으로 운전 중 가동할 경우, 냉각파이프 내의 분진침적에 의한 막힘 방지와 함께 배관 내 침적된 분진을 CCM 내로 다시 처리하는 효과를 기대할 수 있다. 유리화실증시험을 통하여 DRS와 제진장치에 대한 전체적인 성능평가를 성공적으로 수행하였으며, 운전결과 및 경험은 향후 상용설비를 위한 기본자료로 활용할 것이다.

  • PDF