• 제목/요약/키워드: gas concentration

검색결과 4,112건 처리시간 0.027초

지하주차장 내부 일산화탄소 가스 분포의 전산 해석적 평가 (Numerical Evaluation of CO Gas Distribution in Underground Parking Lot)

  • 김재원;함경아
    • 한국전산유체공학회지
    • /
    • 제7권2호
    • /
    • pp.33-42
    • /
    • 2002
  • Numerical estimation for concentration of mono-carbon oxygen (CO) gas inside an underground parking lot with auxiliary jet fans for enhancement of ventilation is carried out by using a commercial program. Main interest lies on the diagnosis of the present ventilation system including position and selection of auxiliarly fans in addition to main suppliers and exhausts. Details of both flows and concentration of CO gas that is most important component among car exhaust gases are illustrated in this investigation and those are presented for engineering construction of an underground parking pool. Prediction data of computational work is also validated by real measurements of concentration of CO gas.

NO Reduction and Oxidation over PAN based-ACF

  • Kim, Je-Young;Lee, Jong-Gyu;Hong, Ik-Pyo
    • Carbon letters
    • /
    • 제1권1호
    • /
    • pp.17-21
    • /
    • 2000
  • Catalytic reduction and oxidation of NO over polyacrylonitrile based activated carbon fibers (PAN-ACF) under various conditions were carried out to develop removal process of NO from the flue gas. The effect of temperature, oxygen concentration and the moisture content for the reduction of NO with ammonia as a reducing agent was investigated. The reduction of NO increased with the oxygen concentration, but decreased with the increased temperature. The moisture content in the flue gas affects the reduction of NO as the inhibition of the adsorption of the other components and the reaction on the surface of ACE For the oxidation of NO to $NO_2$ over PAN-ACF without using a reducing gas, it showed the temperature and the oxygen concentration of the flue gas are the important factors for the NO conversion in which the conversion increased with oxygen concentration and decreased with the temperature increase and might be the alternative option for the selective catalytic reduction process.

  • PDF

PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성 (Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor)

  • 박현희;조항대;김인원;이형근
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.521-528
    • /
    • 2008
  • 중공사막 접촉기에 적절한 PVDF 중공사막을 상전이 공정에 의하여 제조하였으며, SEM 과 기체투과도에 의하여 그 특성을 분석하였다. 벤치규모 중공사막 접촉기에서 $SO_2$ 제거를 위한 흡수제는 수산화나트륨 수용액을 사용하였다. 기체는 shell side, 액체는 lumen side로 흐르는 counter-current로 실험하였으며, 흡수제의 농도, 기체의 유속, 액가스비, 유입 $SO_2$ 농도에 따른 영향을 알아보았으며, 수학적 모델링에 의해 막 물질전달계수($k_m$)를 측정하였다. 흡수제의 농도와 액기비가 증가함에 따라 기-액 계면에서 충분한 알칼리도가 제공되므로, 액체막 저항이 감소하며, 총괄물질전달 용량계수는 증가하였다. 기체유속이 증가함에 따라 기체막저항은 감소하게 되므로 총괄물질전달 용량계수는 증가하였다.

광 계수 방식의 라만 라이다 시스템을 이용한 원격 수소 가스 농도 계측 방법에 대한 연구 (Study of a Method for Measuring Hydrogen Gas Concentration Using a Photon-counting Raman Lidar System)

  • 최인영;백성훈;차정호;김진호
    • 한국광학회지
    • /
    • 제30권3호
    • /
    • pp.114-119
    • /
    • 2019
  • 본 논문은 원격으로 수소 가스의 계측이 가능한 광 계수 방식의 소형 라만 라이다 시스템 개발에 관한 것이다. 수소 가스에 의한 라만 신호는 매우 미약한 신호로서, 신호 대 잡음비가 매우 낮다. 광 계수기는 광 판별기를 갖고 있어, 레이저에 의하여 발생한 배경 신호의 전기적 잡음을 제거할 수 있는 장점을 갖고 있다. 본 연구에서는 출력이 낮은 레이저와 광 계수기를 이용하여 소형의 라만 라이다 시스템을 개발하였다. 개발된 광 계수 방식의 라만 라이다 시스템의 원격 수소 가스 검출 능력을 증명하기 위하여 수소 가스 농도를 조절할 수 있는 가스 챔버를 이용하여 수소 가스 농도 측정 실험을 수행하였다. 그 결과 10 m 거리에서 최소 0.65 vol.%의 수소 가스 농도 검출이 가능하였다.

Effects of Bacterial Fraction and Proportion of Silage and Concentrate on Rumen Fermentation and Gas Production Profile

  • Lee, Sang S.;Chang, M.B.;Ha, J.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권5호
    • /
    • pp.643-647
    • /
    • 2004
  • An in vitro experiment was carried out to investigate effects of solid associated (SAB) and liquid associated bacteria (LAB) and the type of incubation substrate on ruminal fermentation and gas production profiles. Bacterial fraction did not influence total numbers of bacteria. Gas production degradation parameters were significantly influenced by bacterial fraction and type of substrate (p<0.05). There was significant interaction between bacterial fraction and type of substrate in gas production (p<0.01). Total VFA concentration and acetic and propionic acid ratio were also influenced by bacterial fraction and type of substrate with little differences in individual VFA concentration.

A Study on Properties of RF-sputtered Al-doped ZnO Thin Films Prepared with Different Ar Gas Flow Rates

  • Han, Seung Ik;Kim, Hong Bae
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.145-148
    • /
    • 2016
  • This paper, Al-doped ZnO(AZO) thin films for application as transparent conducting oxide films were deposited on the Corning glass substrate by using RF magnetron sputtering system. The effects of various Argon gas flow rates on optical and electrical characteristics of AZO films were investigate sputtering method. The Carrier Concentration is enhanced as Ar gas rate increases, and also the oxygen vacancy concentration. The figure of merit obtained in this study means that AZO films which deposited Ar gas rate of 75 sccm have the highest Carrier concentration and Hall mobility, which have the highest photoelectrical performance that it could be used as transparent electrodes.

열선을 이용한 혼합기체의 농도와 유량의 측정 (Measurement of Gas Concentration and flow Rate Using Hot Wire)

  • 김영한;최종정
    • 제어로봇시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

공동주택 자연침기현상 측정연구 (A Study of Natural Infiltration Phenomenon in Apartment Buildings)

  • 정형호;송준원;홍구표;박철용;김진업;양경모;이복만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.944-949
    • /
    • 2006
  • An infiltration was realized as an important part of ventilation to change fresh air with contaminated air in a house. In this study, it was measured the infiltration in new apartment buildings according to Seasons, height etc. We measured the infiltration by using tracer gas method and did for 24hours. To quantify the infiltration, Sulfur Hexafluoride($SF_6$) gas was used. The Constant Concentration was conducted during experimental process and the concentration of the gas was measured with a gas monitor. In the results of the measurement, the infiltration were appeared over 0.6 ACH in winter and about 0.2 ACH in summer and autumn. Also the infiltration were measured more highly at high and low stories than middle stories in winter.

  • PDF

자동차 실내환경변화에 따른 운전자의 감성변화 (Drivers' Emotional Change According to Environmental Change in the Automobile)

  • 이덕동;백운이;임정옥;허증수;최낙진;서지영;김민정;황태진
    • 대한인간공학회지
    • /
    • 제18권2호
    • /
    • pp.25-34
    • /
    • 1999
  • The objective of this study is to evaluate the emotional change of a driver according to the change of temperature, humidity, $CO_2$ gas concentration and $C_4H_{10}$ gas concentration in the automobile by electroencephalogram(EEG) spectrum analysis. The experiment was performed in an automobile simulated shielding room with healthy volunteers(age : 18-31, male : 14, female : 7). The subject's emotion at every different condition was indexed 11-point scale(+5 : most pleasant, -5 : least pleasant). The emotion index at each condition resulted in as follows; in temperature $1.00(23.5^{\circ}C)$, $-2.33(30.5^{\circ}C)$, in humidity 1.50(45%), -1.50(65%), in $CO_2$ gas concentration 0.67(500ppm), -0.57(6,000ppm), in $C_4H_{10}$ gas concentration -0.25(0ppm), -2.75(1,200ppm). From EEG spectrum analysis, the average mean power frequency(MPF) value at each different condition was shown as follows; in temperature $5.48(23.5^{\circ}C)$, $4.06(30.5^{\circ}C)$, in humidity 11.03(45%), 3.03(65%), in $CO_2$ gas concentration 7.16(500ppm), 6.38(6,000ppm), in $C_4H_{10}$ gas concentration 10.21(0ppm), 2.87(1,200ppm). When the environment became unpleasant to the subject, all of the obtained MPF values were decreased. It was found that there is close agreement between subjective evaluation by subject's scaling and objective evaluation by EEG spectrum analysis at different environment. These results indicated that the EEG spectrum analysis is a proper method to assess emotional response of a driver in the changing automobile environment.

  • PDF

수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향 (Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (I))

  • 김병주;이찬우
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.489-498
    • /
    • 1998
  • Among the heat/mass exchange units composing an absorption system, the absorber, where the refrigerant vapor is absorbed into the liquid solution is the one least understood. In the present study, the effects of non-absorbable gas on the absorption process of aqueous lithium bromide solution falling film inside a vertical tube were experimentally investigated. In the range of film Reynolds number of 30 ~ 195, heat and mass transfer characteristics were investigated as a function of non-absorbable gas volumetric concentration, 0.2 ~ 20%. An increase of non-absorbable gas volumetric concentration degraded the mass transfer rate dramatically in the absorption process. The reduction of mass transfer rate was significant for the addition of small amount of non-absorbable gas to the pure vapor. At film Reynolds number of 130, an increase of non-absorbable gas concentration from 0.2 to 6.0% resulted in the decrease of mass transfer rate by 36% and 20% of non-absorbable gas by 59%. However the decrease of film Nusselt number with the increase of volumetric concentration of non absorbable gas was relatively smaller than the decrease of Sherwood number. Critical film Reynolds number was identified to exist for the maximum heat and mass transfer regardless of the volumetric concentration of non-absorbable gases.