• 제목/요약/키워드: gas concentration

검색결과 4,131건 처리시간 0.046초

Precipitation of Manganese in the p-Xylene Oxidation with Oxygen-Enriched Gas in Liquid Phase

  • Jhung, Sung-Hwa;Park, Youn-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.369-373
    • /
    • 2002
  • The liquid phase oxidation of p-xylene has been carried out with oxygen-enriched gas, and the manganese component was precipitated probably via over-oxidation to $Mn^{4+}$. The precipitation increased with rising oxygen concentration in the reaction gas and occurred mainly in the later part of the oxidation. The activity of the reaction decreased, and the blackening of the product and side reactions to carbon dioxide increased with the degree of precipitation. Precipitation can be decreased with the addition of metal ions, such as cerium, chromium and iron.

광주광역시 광산구 소재 신축 아파트 라돈가스 농도 계측 (Measurement of Rn-222 Gas Concentration of Newly Constructed Apartment House in Gwangju Gwangsan-Gu)

  • 장희준;이상복
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.257-261
    • /
    • 2015
  • 라돈은 우라늄-238과 토륨-232가 방사성붕괴 과정을 거친 후 생성되며, 무색, 무취의 불활성 기체로서 지하 또는 밀폐된 공간에 축적된다. 우라늄-238과 토륨-232는 지각의 암석이나 토양 등에 포함 돼 있다. 건축자재는 암석이나 토양을 재료로하여 만들어 진다. 가스 형태의 라돈은 호흡기를 통해 폐로 유입되고 라돈의 딸핵종이 폐나 기관지에 침적 되어 폐암을 일으키는 원인이 된다. 본 연구는 광주광역시 광산구에 위치한 신축 아파트를 대상으로 창문을 닫고 열은 상태에서 라돈 측정기를 이용하여 측정하였다. 측정 결과로 보아 신축 아파트 실내 평균 라돈농도는 미국 일반인 공기 중 라돈가스 최대허용농도 기준치 4 pCi보다 이하의 값이 나타난다는 것을 볼 수 있다. 측정 결과로 볼 때 신축 아파트의 라돈농도로 인한 피폭은 크지 않을 것으로 예상한다. 그러나 라돈가스가 신체 내에 축적이 되면 폐와 같은 경우는 폐암과 같은 피폭에 의한 피해를 얻을 수 있으므로 방사선 방어적 측면에서 측정 결과와 같이 라돈 농도를 낮추기 위해 창문을 자주 열어 환기를 시켜 피폭을 줄이는 것이 필요하다고 생각 된다.

은 나노 콜로이드를 이용한 돼지분뇨의 악취 저감 효과 (Reduction of Odor Emission from Swine Excreta using Silver Nano Colloid)

  • 김구필;최영수;오광현;구경본;서상룡;유수남;이경환
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.342-347
    • /
    • 2011
  • The effect of SNC(silver nano colloid) on the emission reduction of odors such as ammonia ($NH_3$), hydrogen sulfide ($H_2S$), and methane ($CH_4$) from swine excreta was studied. Silver has been used as an universal antibiotic substance and can reduce the emission of some gases by sterilizing action. Therefore, an apparatus which produces SNC was developed and was conducted its performance test. Also, the SNC made by the apparatus was applied to swine excreta sampled from a piggery in oder to find the effect on the reduction of odor emission. An electrolysis apparatus was developed to produce SNC and its capacity was 0.024 ppm/$hr{\cdot}L$. The effects of SNC on the reduction of odor emission from swine excreta were tested for bad smell gases of ammonia ($NH_3$), hydrogen sulfide ($H_2S$) and methane ($CH_4$). For ammonia gas, factorial experiments were conducted to find the effects of concentration and application rate of SNC. The test results for the different concentrations of 20 ppm, 50 ppm, and 100 ppm showed that the more concentration of SNC was increased, the more emission reduction of ammonia gas increased. From the test results about the effect of application rate, the more SNC was applied, the more emission reduction of $NH_3$ increased. In order to reduce the concentration of $NH_3$ below 5 ppm, SNC of 50 ppm is recommended to be applied at an interval of 6 hours, and is mixed with swine excreta in the volumetric ratio of 4:1. For hydrogen sulfide gas, the concentration was decreased as time went by and was reduced rapidly in the first stage of the tests for all applied concentrations of SNC (20 ppm, 50 ppm, and 100 ppm). Especially, when 100 ml of SNC with 100 ppm was applied, emission of hydrogen sulfide gas was reduced rapidly during early 4 hours after the application of SNC. And, concentration of hydrogen sulfide gas was maintained below 20 ppm after 12 hours. For methane gas, t-test showed that there was no significance on the effect of its application for all applied concentrations of SNC. Therefore, it was concluded that the application of SNC on swine excreta had no effect on the emission reduction of $CH_4$.

유전체 장벽 방전내에서 오존발생 특성 (Ozone Generation Characteristics in Dielectric Barrier Discharge)

  • 이형호;조국희;김영배;서길수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.673-678
    • /
    • 2000
  • The dielectric barrier discharge(DBD) is a common method to create a nonthermal plasma in which electrical energy is used to create electrons with a high average kinetic energy. The unique aspect of dielectric barrier discharges is the large array of short lifetime(10ns) silent discharges created over the surface of the dielectric. A silent discharge is generated when the applied voltage exceeds the breakdown voltage of the carrier gas creating a conduction path between the applied electrode and grounded electrode. As charge accumulates on the dielectric, the electric field is reduced below the breakdown field of the carrier gas and the silent discharge self terminates preventing the DBD cell from producing a thermal arc. In fact, the most significant application of dielectric barrier discharges is to generate ozone for contaminated water treatment. Therefore, experiments were perfomed at 1∼2[bar] pressure using a coaxial geometry single dielectric barrier discharge for ozone concentrations and energy densities. The main result show that the concentration and efficiency of ozone are influenced by gas nature, gas quantity, gas pressure, supplied voltage and frequency.

  • PDF

배출가스 저감장치(DPF) 부착에 따른 사회적 편익 추정 (Estimating Social Benefits According to Exhaust Gas Reduction Devices (DPF))

  • 최성규;김용달;김호경;배진민
    • 자동차안전학회지
    • /
    • 제10권3호
    • /
    • pp.27-31
    • /
    • 2018
  • The People have a bad perception about diesel vehicle because of serious air pollution, increase fine dust and global vehicle company's diesel gate. Starting the project in 2005, Ministry of Environment has been supporting that is exhaust gas reduction devices (DPF) on diesel vehicles in the metropolitan area. During the period of 2017.01.01 to 2017.12.31, 10,030 diesel vehicles installed exhaust gas reduction devices (DPF). Among them, 9,921 diesel vehicles that they have sufficient data for analysis were analyzed amount of particulate matter reduction before and after exhaust gas reduction devices (DPF) was installed. Opacity smoke meter measures the concentration of particulate matter. So concentration of particulate matter was converted into a mass unit, and then calculated the total amount of reduced particulate matter. It was estimated that social benefits is costs required to remove it from the total amount of particulate matter.

하수관내 침전물의 황화수소가스 발생에 관한 연구 (Production of Hydrogen Sulfide Gas from Sediments in Concrete Sewer)

  • 조선형;고영송;남상호
    • 상하수도학회지
    • /
    • 제10권3호
    • /
    • pp.83-91
    • /
    • 1996
  • The pulverized wastes originated from kitchen garbage grinder cause an additional load in sewage treatment plant and water environment. Therefore, several problems occur in sewer, such as microbial corrosion, odor, psychoda and fly interrupting flow of sewage etc. by their precipitation with earth and sand. This study was conducted on two experiments: hydrogen sulfide gas generation from sediments in sewer and anaerobic batch test. In anaerobic batch test, gas generation was increased when organic compounds were increased in concentration. Sulfide was decreased upon decreasing in sulfate concentration. In $H_2S$ gas generation test along the depth of sediments there were two different sampling sites which are apart from about 50 cm each other in a menhole. The one has the thickness of 55 cm from the surface, the other, of 60 cm. The hydrogen sulfide gas production rates were measured based on ranges from 0 to 10 cm, 10 to 20 cm, 20 to 30 cm for two samples. The results obtained were 1.08, between 0 to 10 cm in depth for the sample thickness of 55 cm and 3.07, 5.36, $5.42{\mu}g/g-VS{\cdot}hr$ in order of depth for the sample thickness of 60 cm, respectively.

  • PDF

CFD를 활용한 밀폐공간 가스질식사고의 피해 영향 평가 (An Estimation of the Consequence Analysis for Asphyxiation Accident in Confined Space using C.F.D.)

  • 조완수;김의수
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.28-34
    • /
    • 2018
  • Recently, various engineering approaches have been widely used in the accident investigation field to identify the cause of the accident and to predict damage by accident. Computational analysis is the most commonly used method of accident investigation technique. This technique is mainly used to identify the mechanism of the accident generation and to determine the cause when it is difficult to reproduce the situation at the time of the accident or when it is impossible to perform a reproduction experiment. In this study, The computational fluid dynamics analysis for nitrogen asphyxiation accident generated by defect of building structural between diffusion outlet and cooling tower was performed to determine the inflow path of the suffocation gas, death possibility by concentration of suffocation gas and predicted the time of death due to the accident using 3D modeling and FLACS program. We can quantify diffusion concentration of asphyxiation gas and predict mechanism of death occurrence by accident and evaluate the consequence Analysis through this study. In the future, This method can be widely used in the field of gas safety by improving the reliability and validity of the analysis.

혐기성 유동층 반응기를 이용한 페놀과 카테콜의 처리특성에 관한 연구 (A Study on Treatment Characteristics of the Phenol and Catechol using on Anaerobic Fluidized Bed Reactor)

  • 김민수;박동일;홍종순;장인용
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 1998
  • This study was carried to investigate the treatment characteristics of the phenol and catechol with an anaerobic fluidized bed reactor(AFBR) having a dimension of 9 cm i.d. and 1.25 m height. The reactor was operated at $35\pm 1\circ$C. The COD concentration of the effluent, the gas production rate and the composition of gas were measured to determine the performance of the AFBR as the hydraulic retention time(HRT) was decreased from 2 days to i day at 600 mg/l of the phenol and catechol concentration. Stable treatment of the phenol wastewater could be achieved with the AFBR at 18 days but the catechol wastewater couldn't be. At HRT 2 days, the phenol wastewater showed the COD reduction efficiency of 93% and the gas production of 2.7 l/day and the catechol wastewater was obtained the COD reduction efficiency of 82% and the gas production of 0.72 l/day. Also at HRT 1 day the phenol and catechol wastewater showed the COD reduction efficiency of 95% and 73% and the gas production of 4.0 l/day and 1.25 l/day, respectively.

  • PDF

Preparation of ITO Thin Films for Display Application with $O_2$ Gas Flow Ratio and Input Current by FTS (Facing Targets Sputtering) System

  • Kim, H.W.;Keum, M.J.;Lee, K.S.;Kim, H.K.;Kim, K.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1477-1479
    • /
    • 2005
  • In this work, the ITO thin films were prepared by FTS (Facing Targets Sputtering) system under different sputtering conditions which were varying $O_2$ gas flow, input current at room temperature. As a function of sputtering conditions, electrical and optical properties of prepared ITO thin films were measured. The electrical, optical characteristics and surface roughness of prepared ITO thin films were measured. In the results, as increasing $O_2$ gas 0.1[sccm] to 0.7[sccm], resistivity of ITO thin film was increased with a decreasing carrier concentration, $O_2$ gas over 0.3[sccm] the carrier mobility have a similarly value. Transmittance of prepared ITO thin films were improved at increasing $O_2$ gas 0.1[sccm] to 0.7[sccm]. And transmittance of all of the prepared ITO thin films was over 80%. We could obtain resistivity $6.19{\times}10^{-4}[{\omega}{\cdot}cm]$, carrier mobility $22.9[cm^2/V{\cdot}sec]$, carrier concentration $4.41{\times}10^{20}[cm^{-3}]$ and transmittance over 80% of ITO thin film prepared at working pressure 1mTorr, input current 0.4A without any substrate heating.

  • PDF

회분식 유동층 반응기에서 매체순환식 가스연소기용 대량생산 산소공여입자들의 천연가스 연소특성 (Natural Gas Combustion Characteristics of Mass Produced Oxygen Carrier Particles for Chemical-looping Combustor in a Batch Type Fluidized Bed Reactor)

  • 류호정;김경수;박영성;박문희
    • 한국수소및신에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.151-160
    • /
    • 2009
  • Natural gas combustion characteristics of mass produced oxygen carrier particles were investigated in a batch type bubbling fluidized bed reactor. Five particles, NiO/bentonite, OCN601-650, OCN702-1100, OCN703-950, OCN703-1100 were used as oxygen carrier particles. Natural gas and air were used as reactants for reduction and oxidation, respectively. During reduction reaction, high fuel conversion and high $CO_2$ selectivity were achieved for most of oxygen carriers. During oxidation, NO emission was very low. These results indicate that inherent $CO_2$ separation and low NOx combustion are feasible for the natural gas fueled chemical-looping combustion system. Among the five oxygen carriers, OCN703-1100 particle was selected as the best candidate for demonstration of long-term operation in large-scale chemical-looping combustor from the viewpoints of fuel conversion, $CO_2$ selectivity, $CH_4$ concentration, and CO concentration.