• 제목/요약/키워드: gas concentration

검색결과 4,131건 처리시간 0.032초

다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구 (The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser)

  • 김세원;신명철;이창엽;윤성운;김영일
    • 한국연소학회지
    • /
    • 제17권1호
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.

Analysis of Ozone Concentration by TD and Q-mass Method

  • Lee, Dong-Gyu;Lee, Joon-Ung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권4호
    • /
    • pp.161-165
    • /
    • 2004
  • In order to get oxidizing power enough for growth of a superconductive thin film with oxide gas, concentrated ozone was used. As a method for concentrating ozone, a method for concentrating ozone by adsorbing ozone selectively into silica-gel beads is adopted, and this concentration is analyzed by the ultraviolet absorption method, the thermal decomposition method and the Q-mass analyzing method. Thermal decomposition method is most effective for measurement of a high concentration of ozone. Ozone as concentrated by the adsorption method got to have a concentration of 97 mol % at the maximum, and it was identified that the concentration of the ozone gas was stable for the time while a thin film was formed.

제트확산화염에서의 불활성기체 소화농도 (Flame- Extinguishing Concentrations of Inert Gases in Jet Diffusion Flames)

  • 지정훈;이의주
    • 한국안전학회지
    • /
    • 제24권1호
    • /
    • pp.21-25
    • /
    • 2009
  • Extinguishing limits of laminar ethylene/oxygen flames in both normal and inverse co-flow jet burner have been determined experimentally and computationally. An inert gas($N_2$, Ar, $CO_2$) was added into the oxidizer to find the critical concentration and the effectiveness of the agents on flame extinction. The experimental results showed that the physical aspect of inert gases was main mechanism for flame blow-out as same as cup burner test, but the flow effect should be considered to determine the extinction concentration. The numerical prediction was performed with modified WSR model and the result was in good agreement with the measurements. The experimental and numerical methods could be used for the assessment of various flame suppression agents such as minimum extinguishing concentration.

Sensor Gas Chromatography 시스템을 이용한 고등어(Scomber japonicas)의 신속한 신선도 평가 방법 (Rapid Freshness Evaluation of Mackerel Scomber japonicus Using Sensor Gas Chromatography System)

  • 최정욱;이민경;홍창욱;최재혁;장명기;김꽃봉우리;김고은;박가령;안동현;남택정
    • 한국수산과학회지
    • /
    • 제50권6호
    • /
    • pp.837-840
    • /
    • 2017
  • We developed a method to rapidly evaluate the freshness of fish using a sensor gas chromatography (SGC) system. Mackerel Scomber japonicus was stored at $4^{\circ}C$ for 12 days to create an environment similar to the natural decomposition process. Trimethylamine (TMA) content in mackerel muscle was measured at 3-day intervals using a spectrophotometer. The gas-phase concentration of TMA in whole mackerel was also determined using an SGC system. The muscle TMA content increased over time during storage, as did the gas-phase concentration of TMA. Therefore, this study demonstrated that an SGC system can be used to rapidly measure the gas-phase concentration of TMA in fish during processing.

입사광량의 조절과 이에 따른 비분산 적외선 알코올 센서의 온도 특성과 보정 (Temperature Compensation and Characteristics of Non-dispersive Infrared Alcohol Sensor According to the Intensity of Light)

  • 김진호;조희찬;이승환
    • 센서학회지
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2018
  • In this paper, we describe the thermal characteristics of the output voltages of ethanol gas sensor according to the amount of radiation incident on the infrared sensors located at each focal point of two elliptical waveguides. In order to verify the output characteristics of the gas sensor according to the amount of incident light on the infrared sensor, two combinations of sensor modules were fabricated. Hydrophobic thin film is deposited on one of the reflectors of sensor modules and one of the two infrared sensors was equipped with a hollow disk (10 Ø), and the temperature characteristics of the infrared sensor equipped with the hollow disk (10 Ø) and the infrared sensor without the disk were tested. The temperature was varied from 253 K to 333 K at 10 K intervals based on 298 K. The properties of ethanol gas sensor have been identified with respect to varying temperature for a range of ethanol concentration from 0 ppm to 500 ppm. In the case of an infrared sensor equipped with a hollow disk (10 Ø), the output voltage of the sensor decreased by 0.8 mV and 1 mV, respectively, as the temperature increased. Conversely, the output voltage of the diskless infrared sensor showed an average increase of 67 mV and 57 mV as the temperature increased. The ethanol concentrations estimated on the basis of results show an error of more than 10 % for less than 100 ppm concentration. However, if the ethanol concentration exceeds 100 ppm, the gas concentration can be estimated within the range of ${\pm}10%$.

프로판 엔진의 배기 포트에서 탄화수소 산화율 추정 (Estimation of Hydrocarbon Oxidation by Measuring He Concentrations in an SI Engine Exhaust Port)

  • 이형승;박종범;민경덕;김응서
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.660-667
    • /
    • 2000
  • In order to investigate the exhaust structure and secondary oxidation of unburned hydrocarbon (HC) in the exhaust port, concentrations of individual HC species were measured in exhaust process, the degree of oxidation were obtained. Using a solenoid-driven fast sampling system on single-cylinder research engine fueled with 94% propane, the profiles of unburned hydrocarbons (HCs) and non-fuel HCs with a propane fueled engine were obtained from several locations in the exhaust port during the exhaust process. The sampled gases were analyzed using a gas chromatography of HC species with 4 or lesser carbon atoms. The change of total HC concentration and HC fractions of major components through the exhaust port were discussed. The results showed that non-uniform distribution of HC concentration existed around the exhaust valve and changed with time, and that the exhaust gas exhibited nearly uniform concentration profile at port exit, which was due to mixing and oxidation. Also it could be known that bulk gas with relatively high HC concentration came out through the bottom of the exhaust valve. To estimate the mass-based degree of HC oxidation in the exhaust port from measured HC concentrations, a 3-zone diagnostic cycle simulation and plug flow modeling were used. The degree of oxidation ranged between 26 % and 36 % corresponding to the engine operation conditions.

감두탕(甘豆湯) 약침액(藥鍼液)이 종양세포(腫瘍細胞)에 미치는 영향(影響) (Effects of Gamdutang Aqua-acupuncture Solution on Tumor Cell Lines in vitro)

  • 한상훈;박인규;임창수;문진영;임종국
    • Korean Journal of Acupuncture
    • /
    • 제17권1호
    • /
    • pp.1-10
    • /
    • 2000
  • Gamdutang aqua-acupuncture solution(GAS) and Gamdutang water-extracted solution(GWS) were prepared and tested for potential antitumor activites. It was shown to possess considerable toxicity toward various tumor cell lines. Concentration of $5{\times}\;and\;10{\times}$ of GAS resulted in more than 70% inhibition of growth in Ehrlich ascites tumor cells(EATC), hepa1c1c7 and A549. GAS at the concentration of $10{\times}\;and\;5{\times}$ revealed that more than 60% inhibition in HeLa. GWS showed more than 50% in hibition of growth with EATC, HeLa at the concentration of $5{\times}\;and\;10{\times}$. Toxicity assay with GWS in hepa1c1c7 and A549 revealed that more than 80% inhibition in growth at the concentration of $5{\times}\;and\;10{\times}$. In morphological study, the number of cells were decreased, and the shape of cells was round-form. Most of cells in detached in EATC, Hepa1c1c7, HeLa, and A549 with GAS. These results suggest that GAS has antitumor activity in vitro.

  • PDF

Role of oxygen in plasma induced chemical reactions in solution

  • Ki, Se Hoon;Uhm, Han Sup;Kim, Minsu;Baik, Ku Youn;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.208.2-208.2
    • /
    • 2016
  • Many researchers have paid attention to the studies on the interaction between non-thermal plasma and aqueous solutions for biomedical applications. The gas composition in the plasma is very important. Oxygen and nitrogen are the main gases of interest in biological applications. Especially, we focus on the oxygen concentration. In this experiment, we studied the role of oxygen concentration in plasma induced chemical reactions in solution. At first, the amount of ions are measured according to changing the oxygen concentration. And we checked the relationship between these ions and pH value. Secondly, when the oxygen concentration is changed, it identified the type and amount of radical generated by the plasma. In order to confirm the effect of these chemical property change to biological material, hemoglobin and RBCs are chosen. RBCs are one of the common basic biological cells. Thirdly, when plasma treated according to oxygen concentration in nitrogen feeding gas, oxidation of hemoglobin and RBC is checked. Finally, membrane oxidation of RBC is measured to examine the relation between hemoglobin oxidation and membrane damage through relative hemolysis and Young's modulus. Our results suggest that reactive species generated by the plasma differsdepending on the oxygen concentration changes. The pH values are decreased when oxygen concentration increased. OH decrease and NO increase are also observed. These reactive species makes change of chemical properties of solution. We also able to confirm that the difference in these reactive species to affect the oxidation of the Hb and RBCs. The Hb and RBCs are more oxidized with the high oxygen concentration conditions. But membrane is damaged more by plasma treatment with only nitrogen gas. It is shown that red blood cells membrane damage and oxidation of hemoglobin are not directly related.

  • PDF

유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구 (A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration)

  • 박진엽;진수환;박인규
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

액화천연가스(LNG) 사용시설내의 부취농도 분포 및 관리방법에 관한 연구 (A Study on the Odorization Levels and Management in the Facility using Liquified Natural Gas(LNG))

  • 원승연;신헌용
    • 한국가스학회지
    • /
    • 제23권6호
    • /
    • pp.25-32
    • /
    • 2019
  • 많은 대량소비 가스시설에서는 천연가스를 가스공사의 배관망을 통해 공급받지 못하여 탱크로리를 통해 액화천연가스(LNG)를 가스공사로부터 공급받아 기화시켜 사용한다. 이러한 시설에서 가스 누출로 인한 인명 또는 재산피해를 방지하기 위하여 주입하는 부취제가, 최초지점과 소비지점들에서 어떤 농도로 분포하는지 분석하는 연구를 수행하였다. 일정한 유량이 흐를 때 가스시설내의 배관위치에 따라 부취농도의 변화를 확인하기 위한 분석이 이루어졌다. 시료채취는 알루미늄 재질의 4.5 L 용기를 진공상태로 만든 후, 부취제가 주입되는 정압기와 가스가 사용되는 소비지점에서 시료를 포집하였다. 포집된 가스시료로부터 가스크로마토그래피(Main Body : Agilent 7890A, Detector : ANTEC 7090)를 이용하여 부취제의 농도를 분석하였다. 안전한 가스시설관리를 위하여 대량수요자 시설의 형태별로 부취농도 관리방법의 정립이 필요한 것으로 판단된다.