• Title/Summary/Keyword: gas concentration

Search Result 4,112, Processing Time 0.026 seconds

A Study on Hydrogen Impurity Effect in Anode of Proton Exchange Membrane Fuel Cell on Various Concentration of CO and H2S (고분자전해질 연료전지 연료극의 일산화탄소 및 황화수소 농도에 따른 불순물영향에 관한 연구)

  • LEE, EUN-KYUNG;BAEK, JAE-HOON;LEE, JUNG-WOON;LEE, SEUNG-KUK;LEE, YEON-JAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.670-676
    • /
    • 2016
  • Hydrogen town in Republic of Korea was established in 2013. Hydrogen as a byproduct produced by various processes of factories is used in hydrogen town facilities. As cell performance is affected by contaminations in fuel gas, various standards about impurities of fuel have been determined by many countries. This study shows performance degradation of single cell with impurities concentrations. Traces of carbon monoxide (CO) and hydrogen sulfide ($H_2S$)can cause considerable cell performance losses. For comparing the performances by poisoning of CO, acceleration test, I-V curve, constant current are performed. Both the CO and $H_2S$ poisoning rate are a function of their concentration. With the higher concentrations the higher poisoning rates are observed. And, it was confirmed that, oxidation behavior and side reaction generation are not affected. Under the lower $H_2S$ concentration condition, the poisoning rate is much higher than that of CO because of its different adsorption intensity. It can be possible that the result of this study can be used for enacting regulation as a baseline data.

Analysis of Reactivity of Zn-Based Desulfurization Sorbents for Reducing Power, Water Vapor Content and H2S Content of the Coal Gas in a Batch-Type Fluidized-Bed Reactor (회분식 유동층반응기에서 세 종류 아연계 탈황제의 석탄가스 환원도, 수분함량, 황화수소함량에 따른 반응성 평가)

  • Park, Young Cheol;Jo, Sung-Ho;Son, Jae-Ek;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.710-714
    • /
    • 2009
  • In this study, we analyzed the desulfurization performance of Zn-based dry sorbents according to the reducing power, water vapor content and $H_2S$ inlet concentration of coal gas in a batch-type fluidized-bed reactor. We used three different coal gas composition with different reducing power such as KRW air-blown coal gas, Shell oxygenblown coal gas and IAE coal gas. The experiments were performed by changing the inlet concentration of water vapor and $H_2S$ in a coal gas. Water vapor content was varied from 5% to 30% and $H_2S$ inlet concentration from 0.5% to 2.0%. As both the water vapor content and $H_2S$ inlet concentration increased, desulfurization performance of Zn-based sorbents decreased regardless of the reducing power of the coal gas. The minimum desuflurization performance was, however, above 99.5% for all experimental conditions, which implied that Zn-based dry sorbents could be used to remove $H_2S$ up to 99%.

Risk Assessment of Volatile Organic Compounds for Vapor Intrusion Pathway Using Various Estimation Methodology of Indoor Air Concentration (다양한 실내 침투 휘발물질 농도 예측 방법을 이용한 토양오염물질의 실내흡입 위해성평가)

  • Jung, Jae-Woong;Nam, Taekwoo;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.51-65
    • /
    • 2015
  • Indoor inhalation of vapors intruded into buildings is an important exposure pathway in volatile organic compoundscontaminated sites. Site-specifically measured indoor air concentration is preferentially used for risk assessment. However, when indoor air concentration of VOC is not measured, the indoor air concentration needs to be estimated from soil concentration or measured soil gas concentration of the VOC. Some risk assessment guidance (e.g., Korea Ministry of Environment (KMOE) and American Society for Testing and Materials (ASTM) International guidance) estimate the indoor air concentration from soil concentration while other guidances (e.g., United States Environmental Protection Agency (USEPA) and Dutch National Institute for Public Health (RIVM)) estimate it from measured soil gas concentration. This study derived indoor inhalation risks of intruded benzene in two benzene-contaminated residential areas with four different risk assessment guidances (i.e., KMOE, USEPA, ASTM, and Dutch RIVM) and compared the derived risks. The risk assessment results revealed that indoor air estimation approach from soil concentration could either underestimate (when the contaminant is not detected in soil) or overestimate (when the contaminant is detected in soil even at negligible concentration) the indoor air inhalation risk. Hence, this paper recommends to estimate indoor air concentration from soil gas concentration, rather than soil concentration. Discussions about the various indoor air concentration estimation approaches are provided.

The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment

  • Kim, Hyunjoo;Kim, Jin Seog;Lee, Jongman;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.49-57
    • /
    • 2020
  • Controlling the quality of indoor air is important in order to maintain a healthy life. In this study, we investigated the correlation between the hazardous substance concentration of indoor air and circulation based on different ventilation methods in the apartment, which is one of the representative housing types in Korea. As target substances, we considered the hazardous substances which are generated during the cooking process and radon gas which is originated from building materials. We measured the concentrations of carbon dioxide and fine particles in relation to type of food and ventilation methods in order to determine the change in the concentration levels of hazardous substances which are generated during the cooking process. On the other hand, we measured the concentration of radon gas before and after letting fresh air into a room through windows in order to determine the change in the concentration level of radon gas which is originated from building materials. The results show that turning on the ventilation fan plays a major role in reducing the concentration levels of hazardous substances in the kitchen, and that it is more effective to turn on the ventilation fan during cooking than after cooking to prevent the diffusion of hazardous materials produced by cooking through the indoor air. Also, the results indicate that letting fresh air into a room through windows more than one time a day is necessary to reduce the concentration level of radon gas in the room to safe concentration range.

MEASUREMENT OF $CO_2$ CONCENTRATION AND A/F RATIO USING FAST NDIR ANALYZER ON TRANSIENT CONDITION OF SI ENGINE

  • Lee, S.W.;Kim, W.S.;Lee, J.H.;Park, J.I.;Yoo, J.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.4
    • /
    • pp.385-390
    • /
    • 2006
  • A fast response $CO_2$ analyzer has been developed to study transient characteristics on an SI engine. The analyzer has the delay time of 4.5 ms and time constant of 2.8 ms, which is fast enough to measure $CO_2$ concentration on a transient condition. Wide range of A/F(Air/Fuel) ratio can be estimated using the analyzer with an additional switch type oxygen sensor. The results of measurement of $CO_2$ concentration and A/F ratio on a transient condition including rapid acceleration/deceleration and EGR(Ehxaust Gas Recirculation) on/off are presented and compared with a commercial exhaust gas analyzer and UEGO(Universial Exhaust Gas Oxyzen) sensor.

The Effect of H2 Flow Rate and TMS Concentration on Synthesizing Ultrafine $\beta$-SiC Powder by Vapor Phase Reaction (기상반응에 의한 $\beta$-SiC 초미분말 합성시 수소 가스유량과 TMS 농도의 영향)

  • 유용호;어경훈;소명기
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.8
    • /
    • pp.853-858
    • /
    • 1999
  • To investigate the effect of H2 flow rate and TMS[Si(CH3)4] concentration on synthesizing ultrafine ${\beta}$-SiC powder by vapor phase reaction the experiment was performed at 1100$^{\circ}C$ of the reaction temperature under the condition of 200-2000 cc/min of H2 gas flow rate and 1-10% of TMS concentration respectively. The shape of ${\beta}$-SiC particles synthesized was spherical and the size of particles decreased and the distribution of particles was more uniform with increasing H2 gas flow rate. In this case Si powders were coexisted with ${\beta}$-SiC Pure and ultrafine ${\beta}$-SiC powders without Si were obtained under the condition of above 2% of TMS concentration and below 1500 cc/min of H2 gas flow rate.

  • PDF

Development of On-axis Raman Lidar System for Remotely Measuring Hydrogen Gas at Long Distance (원거리 수소 가스 원격 계측을 위한 On-axis 라만 라이다 장치 개발)

  • Choi, In Young;Baik, Sung Hoon;Lim, Jae Young;Cha, Jung Ho;Kim, Jin Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.119-125
    • /
    • 2018
  • Hydrogen gas is an important and promising energy resource that has no emissions of pollutants during power generation. However, hydrogen gas is very dangerous because it is colorless, odorless, highly flammable, and explosive at low concentration. Conventional techniques for hydrogen gas detection are very difficult for measuring the hydrogen gas distribution at long distances, because they sample the gas to measure its concentration. Raman lidar is one of the techniques for remotely detecting hydrogen gas and measuring the range of the hydrogen gas distribution. A Raman lidar system with an on-axis optical receiver was developed to improve the range of hydrogen gas detection at long distance. To verify the accuracy and improvement in the range of detecting the hydrogen gas, experiments measuring the hydrogen gas concentration are carried out using the developed on-axis Raman lidar system and a gas chamber, to prevent explosion of the hydrogen gas. As a result, our developed on-axis Raman lidar system can measure a minimum hydrogen gas concentration of 0.66 volume percent at a distance of 50 m.

A Study on the Concentration of CO(Carbon Monoxide) by the Length of the Straight Exhaust Tube for Gas Boiler (가스보일러 직관 배기통의 길이에 따른 폐가스(CO)농도 고찰)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Lee, Jong-Rark;Kim, Cheol-Jin;Park, In-Soo;Ha, Tae-Young;Kim, Il-Woo;Choi, Rack-Bum
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.5-9
    • /
    • 2007
  • There have been 3E problems of energy, economy and environment since the earth has its history. Especially, the energy and environment problems have been getting serious after the modem industry revolution. Therefore, the demand of gas as an eco-friendly energy source is getting increased. With the demand of gas, the installation and use of gas boiler is also increased, so human life injury by the waste gas(CO) of boiler goes on increasing every you. Hence, we want to find out the harm to human body through the study on the concentration of CO by the length of the straight exhaust tube of gas boiler. The allowable concentration of CO is 50 ppm. The 3 m of once bended tube starts exceeding the allowable concentration of CO after 5 minutes, and the 4 m and 5 m starts exceeding after 3 minutes.

  • PDF

Development of a Gas Mixing System for Controlled Atmosphere(CA) Chambers

  • Yun, Hong-Sun;Lee, Hyun-Dong;Lee, Won-Ock;Chung, Hun;Cho, Kwang-Hwan
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.31-36
    • /
    • 2001
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and cheap gas mixing system was developed for controlling gas compositions in CA chambers. The gas flow rate through capillary tube had a linear relationship with pressure, (length)$^{-1}$ and (radius)$^4$ of capillary tube, which agreed well with Hagen-Poiseuille’s law. The relationship between flow rate and combined parameters was described as Q=0.000209724($\pi$ r$^4$P/$\mu$L) and the coefficient of determination was 0.9984. The developed system could control gas concentrations in CA chambers within $\pm$0.3% deviation compared to the preset concentrations. It was possible to predict the required time and required gas flow rate for exchanging the gs in CA chamber to a certain concentration of gas by using the mathematical model developed in this study.

  • PDF

A Study on the Concentration of CO(Carbon Monoxide) by the Length of the Curved Exhaust Tube for Household Gas Boiler (가정용 가스보일러 곡관 배기통의 길이 변화에 따른 CO농도 고찰)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Ma, Sung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1220-1226
    • /
    • 2007
  • As the industry of 21C has been developed, the gas industry has grown and it has not only the convenience but also the riskiness fer using. Especially, the energy and environment problems have been getting serious after the modern industry revolution. Therefore, the demand of gas as an eco-friendly energy source is getting increased. With the demand of gas, the installation and use of gas boiler is also increased, so human life injury by the waste gas(CO) of boiler goes on increasing every year. Therefore, we want to find out the harm to human body through the study on the concentration of CO by the length of the curved exhaust tube of boiler. The allowable concentration of CO is 50ppm. The length of the one-meter-three-curved tube after three minutes is applicable to 50ppm of the threshold limit values of CO. Also, five meters exceed the threshold limit values of CO after five minutes. Strangely, the concentration of CO is under the threshold limit values from two to four meters.