• 제목/요약/키워드: gas accidents

검색결과 527건 처리시간 0.025초

정면 오프셋 충돌시 가스튜브를 이용한 차량용 범퍼의 손상성, 수리성에 대한 연구 (A Study on the Damageability and Repairability of the Car Bumper Systems with Gas Tube)

  • 조휘창;박인송
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.134-139
    • /
    • 2003
  • The car crash accidents in low speed occurs most frequently. Damage on a conventional bumper after the car accident causes the bumper to get fixed most of time. This study shows how a gas tube bumper reduces a damageability and increase repairability after the car accidents. The 15 km/h 40% offset front and rear crash test recommended by RCAR (Research council for automobile repairs) standard was performed and evaluated damages on the gas tube bumper by the pendulum impact tester. In this study, the gas tube bumper reduces damageability and increases repairability after car crash accidents. In addition, car frame design to apply the gas tube bumper may consider to be changed.

국내 수소사고사례 분석 (Analysis of Hydrogen Accident in Korea)

  • 조영도;탁송수;최경석;이종락;박교식
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.82-87
    • /
    • 2004
  • Hydrogen is considered to be the most important future energy carrier in many applications reducing greenhouse gas emissions significantly. To be applicable as energy carrier the safety issues associated with hydrogen applications needs to be investigated and fully understood. In order to analyze the risks associated with hydrogen applications, accidents associated with hydrogen in Korea from 1963 to 2002 have been analysed in this work. From analysis of accidents, we propose the necessity of research on hydrogen releases, dispersion in air, and explosion due to high hazardous of hydrogen.

업무용대형연소기 안전기준 개선방안 연구 (A Study on Improvement of Safety Standards for Commercial Gas Burning Appliances)

  • 최슬기;안현수;이창언;김영구
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.309-310
    • /
    • 2014
  • Commercial gas burning appliances are classified by KGS AB338. Even though there are many types of gas appliances with different purposes and uses, common standards are applied to the appliances. Manifold of commercial gas range could often be corroded by salt water. Gas leaks and accidents could be occurred by the corrosion. According to suggestion of detailed material standards for manifold of commercial gas range, it could help to use safely and prevent gas accidents.

  • PDF

가스 소비자들의 가스안전성 제고를 위한 가스기기 사용 실태 및 가스안전의식 조사에 관한 연구 (A Study on the Actual Condition of Gas Equipment and Gas Safety Consciousness Survey to Improve Gas Safety of Gas Consumers)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제13권4호
    • /
    • pp.465-475
    • /
    • 2017
  • 가스를 사용하고 있는 사용자에 대한 설문조사 결과 2010년도를 기점으로 가스안전사고는 급감하고 있으나, 가스사고 발생 세부원인을 분석해 보면 최근에는 취급부주의에 의한 사고가 62%로 증가측면을 보이고 있어 이에 대한 대책이 시급한 것으로 분석 되었다. 또한 10가구 당 7가구 꼴로 가스가 안전한 것으로 인식하고 있지만, 이 중 30%는 향후 가스안전사고가 자신의 집에서 발생할 가능성이 있다고 인식하고 있어 가스이용이 상대적으로 안전하기는 하지만 여전히 사고의 위험성이 상존하고 있다는 것을 인식하고 있는 것으로 나타났다. 이러한 가스 소비자의 가스안전에 대한 인식은 연령, 성별, 소득수준 등과는 무관한 것으로 분석된 반면, 고학력자이며, 직, 간접적인 가스안전사고 경험이 있고, 가스안전점검 요령을 미숙지하고 있는 사람일수록 가스사용의 안전성에 대한 인식이 상대적으로 낮게 나타났다. 아울러 가스안전사고를 줄이기 위해 노령층 가구에 대한 가스안전기기 설치가 지속적으로 보급되어야 할 것이다.

3상 170 kV 가스절연개폐장치(GIS)의 사고 원인 분석 및 예방 대책 (Analysis of the Causes of Accidents Related to 3 Phase 170 kV Gas Insulated Switchgears(GIS) and Preventive Measures)

  • 최충석
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.41-46
    • /
    • 2011
  • The purpose of this paper is to analyze the causes of accidents related to the 3 phase 170 kV gas insulated switchgear of a power system collected from accident sites to secure data for the prevention of similar accidents and provide important points of view regarding diagnosis for the prevention of accidents involving gas insulated switchgears. The analysis results of the causes of accidents involving gas insulated switchgears showed deformation of the manipulation lever installed at the S-phase, disconnection of the insulation rod connection, melting of the upper conductor, a damaged tulip, damage to the lower spacer and the spacer at the breaker, etc. It is believed from this result that the potential for accidents has expanded due to accumulated energy as a result of repeated deterioration. The carbonization depth of a GIS was formed near the screw (T2, T3) used to secure the lower pole of the S-phase tulip. It is not known what has caused the screws to be extruded and melted. However, it is thought that an unbalanced electromagnetic force, micro-discharge, surface discharge, etc., have occurred at that point. In addition, even though 16 years have passed since its installation, there was no installation defect, act of arson, accidental fire, etc. General periodical inspection and diagnosis failed to find the factors causing the accidents. As a system contained in a closed metal container, it has a high risk factor. Therefore, it is necessary to design, install and operate a GIS in accordance with the standard operational procedure (SOP). In addition, it is necessary to apply conversion technology for periodical SF6 gas analysis and precision safety diagnosis. It is expected that tracking and managing these changes in characteristics by recording the results on the history card will provide a significant accident prevention effect.

시계열 분석을 이용한 가스사고 발생 예측 연구 (The Study of Prediction Model of Gas Accidents Using Time Series Analysis)

  • 이수경;허영택;신동일;송동우;김기성
    • 한국가스학회지
    • /
    • 제18권1호
    • /
    • pp.8-16
    • /
    • 2014
  • 본 연구에서는 국내에서 발생한 가스사고를 분석하여 가스사고의 건수예측모델에 대하여 제시하였다. 가스사고 건수를 예측하기 위하여 단순이동평균법(3,4,5기간), 가중이동평균법 및 지수평활법을 적용해 본 결과, 4기간 이동평균법과 가중이동평균법에 의한 모델의 평균오차제곱합이 44.4와 43으로 가장 정확성이 높은 것으로 나타났다. 가스사고 발생건수 예측시스템을 개발함으로서 가스사고 예방활동에 적극 활용할 수 있을 것이다.

국내 LP 및 천연가스사고 Database 구축 및 분석에 관한 연구 (Constructing a Database Structure for the Domestic LP Gas and Natural Gas Accidents and its Analysis)

  • 고재선;박선영;김효
    • 한국가스학회지
    • /
    • 제12권3호
    • /
    • pp.56-63
    • /
    • 2008
  • 본 연구에서는 1991년부터 최근까지 16년간 발생된 3,593건의 가스사고[천연가스(NG) 및 액화석유가스(LPG)]사례를 수집하여 Database를 구축하였으며, 이를 근거로 사고의 발생건수를 형태 및 원인별로 분석하였다. 분석결과를 살펴보면 사고의 형태로는 누출, 폭발, 그리고 화재의 순서로 많이 발생하였다. 사고발생위치로는 화재는 밸브부위에서, 폭발은 호스부위에서, 그리고 누출은 배관부근에서 가스사고가 많이 발생한 것으로 나타났다. 또한 화재, 폭발, 누출의 각각의 경우에 Poisson 분석법을 적용하여 향후 5년 이내의 화재, 폭발 및 누출에 대한 가장 가능성이 높은 발생확률을 예측하였다. 향후 본 연구에서 구축한 국내가스사고 Database를 매년 지속적으로 보완 개정을 하면 국내 가스사고 예측에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있어 효과적인 가스안전관리 대책수립에 기여할 것으로 기대된다.

  • PDF

Poisson분포를 이용한 도시가스 화재 폭발사고의 발생 예측프로그램 및 사회적 위험기준에 관한 연구 (Study on Predictable Program of Fire.Explosion Accident Using Poisson Distribution Function & Societal Risk Criteria in City Gas)

  • 고재선;김효;이수경
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.6-14
    • /
    • 2006
  • 가스로 인한 화재 및 폭발사고의 예측 가능한 프로그램을 구체화하고, 적절한 사회적 위험기준을 제시하기 위하여 최근 11년간의 가스사고 데이터베이스를 분석하였다. 먼저 동일유형의 가스사고 발생가능 성을 판단할 수 있는 Poisson 분석 방법을 적용하기 위해 3개의 사고유형, 즉 누출, 폭발, 화재로 구분하여 총 16개 항목으로 나누어서 적용하였다. 그 결과, 시공 작업 부주의-폭발-배관의 항목의 사고발생반도가 가장 작았으며, 배관연결부이완부식-누출-배관의 경우는 가장 높은 빈도를 나타내었다. 따라서 이에 대한 적절한 가스사고 대응책이 마련되어야 할 것이다. 또한 치명적인 가스사고의 추세와 합리적인 위험정책에 대한 지침을 결정하기위해 D. O. Hagon 방정식과 회기직선식을 이용하여 F.N 곡선의 누적사망자의 최소 및 최대점에 대응시켜 허용가능영역을 설정하였다. 향후 가스사고에 대한 신뢰성 있는 분석을 위해서는 가스로 인한 화재 폭발사고에 대한 데이터베이스를 지속적으로 확충보완을 시켜야 되며, 이를 위한 표준 코드화 작업이 요구된다.

도시가스 누출에 따른 스마트 홈 안전 플랫폼 프로그램 구축 (Smart Home Safety Platform Program for City Gas Leakage)

  • 지현민;이우귀연;오정석
    • 한국가스학회지
    • /
    • 제23권6호
    • /
    • pp.97-102
    • /
    • 2019
  • 본 연구에서는 우리나라 가정에서 가장 많이 쓰이고 있는 LNG를 대상이며 수요가 증가함에 따라 가스사고는 늘어나고 있는 실정이다. 그 중 사용자취급부주의로 인한 사고가 가장 많은데 이를 효과적으로 미연에 방지 하고자 시나리오를 구축하여 정보제공을 하고자한다. 가정에서의 가스누출은 밀폐 된 공간이며 이에 따른 적합한 gaussian model을 적용하였다. 4차 산업 혁명으로 스마트 홈 제어 기술이 발전함에 따라 가스누출사고를 예측하고 방지하고자 프로그램으로 정보제공을 할 수 있는 토대를 만들어 스마트 홈 안전 플랫폼에 적용하고자 한다.

가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰 (A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System)

  • 유원주;이승현
    • 대한안전경영과학회지
    • /
    • 제12권2호
    • /
    • pp.75-82
    • /
    • 2010
  • Gas turbines for power generating operate in a very high temperature condition and use natural gas for fuel. For this reason, many cases of damage happen at hot gas parts which are severely affected by high temperature gas and many cases of explosion occur by fuel gas. So a lot of efforts should be made to prevent hot gas parts damage and gas explosion accidents. Though there are many damage cases and explosion accidents, it is very difficult to find out the root causes of hot gas parts damage caused by gas explosion due to gas leakage in the heat exchanger for air cooling and gas heating. To prevent gas turbine from damage caused by gas explosion, removal of leakage gas from gas turbine is inevitably required before firing the gas turbine and installing alarm systems is also required for detecting gas leakage at stop valve to turbine while shut down.