• Title/Summary/Keyword: gas CRM

Search Result 17, Processing Time 0.016 seconds

Development of Certified Reference Materials for Specific Surface Area (비표면적 인증표준물질 개발)

  • Choi, Byung Il;Kim, Jong Chul;Kim, Taeyoung;Nham, Hyunsoo;Kwon, Su Yong
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.74-84
    • /
    • 2005
  • Understandings of adsorption characteristic of interface are very important in several advanced materials processes, related to NT and BT technology. Volumetric gas adsorption method, suitable for absolute measurements, is regarded as the standardized measurement technique for specific surface area. In order to verify the reliability of commercial equipments, certified reference materials (called CRM) of specific surface area are developed and evaluated its uncertainty factors by standard equipment which has traceability to SI units. Specific surface areas of developed materials are $10.72{\pm}0.46m^2g^{-1}$ for silicon nitride powders and $149.50{\pm}3.44m^2g^{-1}$ for alumina. These disseminations of CRMs would result in improved reliability chains in industrial processes, and lead eventually to contribution to productivity improvement, quality management, safety evaluation, and possibly to new material development.

Using GAs to Support Feature Weighting and Instance Selection in CBR for CRM

  • Ahn, Hyun-Chul;Kim, Kyoung-Jae;Han, In-Goo
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2005.11a
    • /
    • pp.516-525
    • /
    • 2005
  • Case-based reasoning (CBR) has been widely used in various areas due to its convenience and strength in complex problem solving. Generally, in order to obtain successful results from CBR, effective retrieval of useful prior cases for the given problem is essential. However, designing a good matching and retrieval mechanism for CBR systems is still a controversial research issue. Most prior studies have tried to optimize the weights of the features or selection process of appropriate instances. But, these approaches have been performed independently until now. Simultaneous optimization of these components may lead to better performance than in naive models. In particular, there have been few attempts to simultaneously optimize the weight of the features and selection of the instances for CBR. Here we suggest a simultaneous optimization model of these components using a genetic algorithm (GA). We apply it to a customer classification model which utilizes demographic characteristics of customers as inputs to predict their buying behavior for a specific product. Experimental results show that simultaneously optimized CBR may improve the classification accuracy and outperform various optimized models of CBR as well as other classification models including logistic regression, multiple discriminant analysis, artificial neural networks and support vector machines.

  • PDF

The Study on Analysis Method and Performance Evaluation of Portable GC/MS (휴대용 GC/MS 성능검사 및 분석방법 연구)

  • Park, Yuonshin;Noh, Hyeran;Yang, Heeseon;Seok, Gwanseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • Recieved Mar. 06, 2013 Revised Mar. 29, 2013 Accepted Sep. 11, 2013In this study, we evaluated the method performance and the optimum sample injection method of the portable GC/MS(HAPSITE) which were designed to operate on scene of chemical accidents. Chemicals used for performance test were vinyl chloride(VC), methyl chloride(MC), benzene(Bz), toluene(Tol). CRM(Certified Reference Material) Manufactured by KRISS(Korea Research Institute of Standards and Science) was used as the standard gas. The results showed that 1) Among three sample injection methods(Cylinder, Silico canister, and Bag), bag was identified as the most appropriate sample injection method. Bag material and capacity did not significantly affect the results. The most ideal reproducibility occurred at the 2-minute point of the purge time in the loop and tenax methods. 2) Performance evaluation of HAPSITE was conducted. Evaluation items were reproducibility, linearity, method detection limit, etc. Tenax concentration method was appropriate for larger molecules and Carbopack concentration method was suitable for smaller molecules.

Purity assignment of 17β-estradiol by mass balance method

  • Lee, Hwa-Shim;Oh, Kwang-Hoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.226-233
    • /
    • 2017
  • In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.

Prediction of Indoor Radon Concentration through the Exhalation from Korean Yellow Residual Soil, Hwangtoh as a Building Material

  • LEE, Ju Yong;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.122-133
    • /
    • 2021
  • The radon gas from nature mainly considers a cause of radon problems, and it is closely affect human life cycle. Korean yellow residual soil, Hwangtoh, widely used as a building material, is considered to be one of major sources of indoor radon. However, there have, as yet, been no studies about radon from Hwangtoh in mass market brands. Here, we investigated the indoor radon concentrations and exhalation rates in four Hwangtohs from different brand names and regional features. The Closed Chamber Method (CCM) conducted by a Continuous Radon Monitor (CRM) has been used for the rates of radon exhalation. Based on equations of previous references, the indoor radon concentrations were deducted. As a result, the radon surface exhalation rates resulted in the 1.4208 to 3.0293 Bq·㎡·h-1 range. Significant differences were found among Hwangtohs according to production regions. Materials with higher radon concentration required a longer time to reach a quasi-steady state in a given environment, in other words, the number of half-life cycles increased from a set starting point. The experimentally identified Hwangtohs demonstrated its safety for construction purposes. There exists, so far, a possibility to exert influence radon emanation due to unidentified factors. Therefore, it is necessary to corroborate with more research by increasing the number of Hwangtohs, considering the other references reported high radon exhalation rates. In addition, it is highly recommended that the radon exhalation rates should be measured for all building materials for preventing human health before the material usage.

Determination of trace arsenic in seawater by flow injection-hydride generation inductively coupled plasma mass spectrometry (연속흐름주입-수소화물생성-유도결합플라스마 질량분석장치를 이용한 바닷물표준시료중의 극미량 비소분석방법의 확립)

  • Suh, Jung-Ki
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.316-325
    • /
    • 2008
  • An inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with flow injection-hydride generation system was used for the determination of trace arsenic in seawater sample. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of seawater (CASS-4, NASS-5). The analytical results agreed with certified value within the range of uncertainty. The expanded uncertainties for CASS-4 and NASS-5 in this experiment were ranged from 6.2% to 6.8% obtained from repeated analyses of the CRMs (n=5). The detection limit of $As^+$ (m/z=74.9216) in this method was confirmed about 0.01 ug/kg. Linearity obtained from calibration curve of arsenic was excellent ($R^2=1$). The detection at $As^+$ (m/z=74.9216) and $AsO^+$ (m/z=90.9165) by using oxygen reaction gas in DRC mode was compared. Sensitivity at $AsO^+$ (m/z=90.9165) was decreased about 25-fold, but the analytical results are the same that at $As^+$ (m/z=74.9216).

Application of Dynamic Reaction Cell - Inductively Coupled Plasma Mass Spectrometry for the Determination of Calcium by Isotope Dilution Method (반응셀 유도결합플라스마 질량분석분석기를 이용한 칼슘 동위원소비율의 측정과 동위원소희석법의 적용)

  • Suh, Jungkee;Yim, Yonghyeon;Hwang, Euijin;Lee, Sanghak
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.417-426
    • /
    • 2002
  • Inductively Coupled Plasma Dynamic Reaction Cell Quadrupole Mass Spectrometry (ICP-DRC-QMS) was characterized for the detection of the six naturally occurring calcium isotopes. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio. This experiment shows that the potentially interfering ions such as $Ar^+$, ${CO_2}^+$, ${NO_2}^+$, $CNO^+$ at the calcium masses m/z 40, 42, 43, 44 and 48 were removed by flowing $NH_3$ gas at the rate of 0.7 mL/min $NH_3$ as reactive cell gas in the DRC with a RPq value (rejection parameter) of 0.6. The limits of detection for $^{40}Ca$, $^{42}Ca$, $^{43}Ca$, $^{44}Ca$, and $^{48}Ca$ were 1, 29, 169, 34, and 15 pg/mL, respectively. This method was applied to the determination of calcium in synthetic food digest samples (CCQM-P13) provided by LGC for international comparison. The isotope dilution method was used for the determination of calcium in the samples. The uncertainty evaluation was performed according to the ISO/GUM and EURACHEM guidelines. The determined mean concentration and its expanded uncertainty of calcium was ($66.4{\pm}1.2$) mg/kg. In order to assess our method, two reference samples, Riverine Water reference sample (NRCC SLRS-3) and Trace Elements in Water reference sample (NIST SRM 1643d), were analyzed.