• 제목/요약/키워드: gap width

검색결과 490건 처리시간 0.029초

박막 증착공정을 사용하여 구현된 초소형 RFID 태그 안테나 (Small RFID Tag Antenna Based on Thin-film Deposition Process)

  • 정태환;김정연;김병국;박승범;이석진;안상기;우덕현;권순용;임동건;박재환;안중수
    • 한국전기전자재료학회논문지
    • /
    • 제22권4호
    • /
    • pp.285-289
    • /
    • 2009
  • Small RFID tag antenna were fabricated on Si substrate and their physical and electrical properties were evaluated. With decreasing the size of tag antenna on Si substrate, small SMD-type RFID tags could be fabricated, which is very useful for various applications including PCB tracking. Firstly, electromagnetic properties on tag antenna pattern were simulated with HFSS. The setup frequency was 13.56 MHz of HF-band RFID. The line-width and line-gap were modeled in the range of $50{\sim}200{\mu}m$. S parameters, SRF, and Q value were calculated from the model. When the line-width and line-gap were 100 urn and the loop-turn was 10, the SRF was 80 MHz and the Q value was ca. 9. When the microstrip antenna pattern of aluminum was fabricated by using DC sputtering, Vpp of ca. 1.6 V was obtained when the reader-tag distance was 40 mm.

미세 전극 패턴을 갖는 알루미나 정전척을 이용한 LED용 사파이어 기판 흡착 연구 (A Study on the Holding of LED Sapphire Substrate Using Alumina Electrostatic Chuck with Fine Electrode Pattern)

  • 김형주;신용건;안호갑;김동원
    • 한국표면공학회지
    • /
    • 제44권4호
    • /
    • pp.165-171
    • /
    • 2011
  • In this work, handling of sapphire substrate for LED by using an electrostatic chuck was studied. The electrostatic chuck consisted of alumina dielectric, which was doped with 1.2 wt% $TiO_2$. As the volume resistivity of alumina dielectric was decreased, the electrostatic force was increased by Johnsen-Rahbek effect. The narrower width and gap size of electrode led to the stronger electrostatic force. When alumina dielectric with $3.20{\times}10^{11}{\Omega}{\cdot}cm$ resistivity and 3 mm width/1.5 mm gap sized electrode was used, the strongest electrostatic force in this work was obtained, which value reached to ~14.46 gf/$cm^2$ at 2.5 kV for 4-inch sapphire substrate. This results show that alumina electrostatic chuck with low resistivity and fine electrode pattern is suitable for handling of sapphire substrate for LED.

Design and evaluation of the thermal capability to secure a working time of cryogenic explosion-proof camera in LNG carrier tank

  • Kang, Geun-Il;Kwak, Si-Young;Park, Chun-Seong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권5호
    • /
    • pp.568-576
    • /
    • 2017
  • With an increase in the usage of LNG, there is a heightened interest about its safety aspects regarding the explosion of LNG carrier tank. The need for a cryogenic explosion-proof camera has increased. The camera has to work in cryogenic environment (below $-160^{\circ}C$) in LNG carrier. This study conducted design and heat transfer analysis of cryogenic camera to secure working time in limitation of heat source. The design with gap width of double pane windows was conducted based on simple vertical cavity model to insulate from cryogenic environment. The optimal gap width was 12.5 mm. For effective analysis considering convection within the camera, equivalent thermal conductivity method was adopted with ABAQUS. The working time of the camera predicted was over 10 h at warm-start condition. In cold-start condition, it required about 5 h of pre-warming time to work. The results of analysis were compared with the ones of the actual cryogenic test.

Heat transfer and flow characteristics of a cooling thimble in a molten salt reactor residual heat removal system

  • Yang, Zonghao;Meng, Zhaoming;Yan, Changqi;Chen, Kailun
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1617-1628
    • /
    • 2017
  • In the passive residual heat removal system of a molten salt reactor, one of the residual heat removal methods is to use the thimble-type heat transfer elements of the drain salt tank to remove the residual heat of fuel salts. An experimental loop is designed and built with a single heat transfer element to analyze the heat transfer and flow characteristics. In this research, the influence of the size of a three-layer thimble-type heat transfer element on the heat transfer rate is analyzed. Two methods are used to obtain the heat transfer rate, and a difference of results between methods is approximately 5%. The gas gap width between the thimble and the bayonet has a large effect on the heat transfer rate. As the gas gap width increases from 1.0 mm to 11.0 mm, the heat transfer rate decreases from 5.2 kW to 1.6 kW. In addition, a natural circulation startup process is described in this paper. Finally, flashing natural circulation instability has been observed in this thimble-type heat transfer element.

4 segment 코일타입 전극구조의 진공 인터럽터에서 접점전극의 슬롯의 길이와 폭이 전극사이의 측자계에 미치는 영향 (Influence of the length and width of the slots of contact electrode on axial magnetic field at the mid-gap in 4 segment coil type vacuum interrupter)

  • 김병철;윤재훈;박성희;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.210-211
    • /
    • 2007
  • Once high current flows through the vacuum interrupter, eddy current occurs due to the time-varying axial magnetic field caused by the current(AC) and it causes a decrease in axial magnetic field generated by current flowing through coil electrode. but if there are slots on contact electrode it is possible to increase the amplitude of axial magnetic field by reducing the influence of eddy current. there has been many studies about the number of slot of the contact electrode[1][2][3]. In this paper, in addition to these previous results we deal with the influence of the length and width of the slots on axial magnetic field at the mid-gap plane in 4 segment coil type vacuum interrupter by using 3D finite element method software.

  • PDF

아몰퍼스 와이어의 ECT probe 적용에 대한 검토 (Application of Amorphous wire to ECT(Eddy Current Testing) Probe)

  • 김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2002
  • ECT(eddy currentign testing) is very effective technique to detect a flaw within a conductor. Co-based amorphous wire was used as a sensor head. The wire has almost 0 magneto-striction and high permeability. An uniform magnetic field was applied to 1mm thick copper plate and $25{\mu}m$ thick aluminum sheet conductor using spiral typed coil The size of the coil has $40mm{\times}40mm$ outer width and $8mm{\times}8mm$ inner width. The copper plate and aluminum sheet has 0.5mm and 0.1mm wide gap, respectively. The frequency range of applied field was 100kHz-600kHz. The induced voltage difference of 2.5mV was obtained in the maximum voltage and minimum one measured across the gap of the 1mm thick conductor. In the case of aluminum sheet, 0.4mV was obtained. From this results, the effectiveness of Co-based amorphous wire was confirmed in the ECT technique.

  • PDF

수술 후 컴퓨터 단층촬영을 이용한 관절 내 종골 골절의 정복과 임상 결과 간의 연관성 분석 (Correlation Analysis of Reduction for Intra-Articular Calcaneal Fracture and Clinical Outcomes Using Postoperative Computed Tomography)

  • 엄준상;주영득;김성준;신민호;이동오;정홍근
    • 대한족부족관절학회지
    • /
    • 제18권4호
    • /
    • pp.165-172
    • /
    • 2014
  • Purpose: We evaluated the correlation of postoperative clinical outcomes and radiologic findings using computed tomography and simple X-ray in intra-articular calcaneal fractures. Materials and Methods: The current study is based on 41 feet, 38 patients with displaced intra-articular fracture who underwent surgical treatment with at least one year of follow-up. Evaluation of clinical outcome included American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) score, and subjective satisfaction. A simple X-ray was used in evaluation of preoperative and postoperative Gissane angle, B${\ddot{O}}$hler angle, and calcaneal fracture width. Computed tomography scan was performed for evaluation of preoperative and postoperative articular step-off and articular gap in all cases. Finally, we evaluated the correlation of the postoperative clinical outcomes and radiologic findings based on the measurement. Results: The average postoperative AOFAS score and VAS score was $84.1{\pm}8.5$ and $2.2{\pm}2.2$. Subjective satisfaction was excellent in 15 cases, good in 19 cases, and fair in seven cases. The average B${\ddot{O}}$hler angle was restored from $11.1^{\circ}$ to $24.7^{\circ}$(p<0.05), Gissane angle was changed from $121.0^{\circ}$ to $119.0^{\circ}$ (p>0.05), and the average width was restored from 45.8 to 35.0 mm (p<0.05). The average articular step-off and gap were decreased from 6.3 to 2.0 mm and from 11.1 to 4.6 mm, respectively (p<0.05). No significant correlations were observed between the clinical outcome and Gissane angle, B${\ddot{O}}$hler angle, and width, and there was no significant correlation between the clinical outcome and Sanders classification. However, postoperative articular step-off showed correlation with VAS and AOFAS score and articular gap showed correlation with VAS score. Conclusion: The clinical outcome did not show correlation with B${\ddot{O}}$hler angle and Gissane angle but did show correlation with anatomical reduction of the posterior facet joint.

설상사주 형성조건하에 있는 3차원투과성잠제 주변에서 수면변동의 특성 (Characteristics of Water Surface Variations around 3-Dimensional Permeable Submerged Breakwaters under the Conditions of Salient Formation)

  • 이광호;배주현;안성욱;김도삼
    • 한국해안·해양공학회논문집
    • /
    • 제29권6호
    • /
    • pp.335-349
    • /
    • 2017
  • 수중에 설치되는 잠제는 해안침식을 방어하기 위한 대표적인 연안구조물로 지금까지 다양한 형태의 잠제가 제안 연구되어 왔다. 이와 같은 잠제는 천단에서의 급격한 수심변화에 의해 구조물 주변에서 복잡한 파동장을 형성한다. 본 연구는 3차원투과성잠제를 대상으로 잠제 주변에서 형성되는 파고분포 및 평균수위분포를 수치적으로 검토하였다. 수치해석에는 오픈소스 CFD 소스코드인 OLAFOAM을 적용하였으며, 투과성직립벽 및 불투과성 잠제에 대한 기존의 실험결과와의 비교를 통해 수치해석모델의 적용성을 검증하였다. 이를 바탕으로 설상사주의 형성조건에 있는 투과성잠제 주변에서 형성되는 파고분포 및 평균수위분포를 검토하였다. 수치해석결과, 잠제 사이의 개구부 폭이 감소할수록 개구부 중앙에서는 파고가 증가하지만 개구부 배후에서는 개구폭이 증가할수록 파고가 증가하며, 연안으로부터의 잠제 설치위치는 파고의 변화에 크게 영향을 미치지 않음을 확인하였다. 또한, 잠제의 개구부 폭이 감소함에 따라 잠제 개구부의 제두부 근방에서 평균수위 하강이 증가함을 확인하였다.

Mitigation of seismic collision between adjacent structures using roof water tanks

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.171-184
    • /
    • 2020
  • The potential of using the roof water tanks as a mitigation measure to minimize the required separation gap and induced pounding forces due to collisions is investigated. The investigation is carried out using nonlinear dynamic analysis for two adjacent 3-story buildings with different dynamic characteristics under two real earthquake motions. For such analysis, nonlinear viscoelastic model is used to simulate forces due to impact. The sloshing force due to water movement is modelled in terms of width of the water tank and the instantaneous wave heights at the end wall. The effect of roof water tanks on the story's responses, separation gap, and magnitude and number of induced pounding forces are investigated. The influence of structural stiffness and storey mass are investigated as well. It is found that pounding causes instantaneous acceleration pulses in the colliding buildings, but the existence of roof water tanks eliminates such acceleration pulses. At the same time the water tanks effectively reduce the number of collisions as well as the magnitude of the induced impact forces. Moreover, buildings without constructed water tanks require wider separation gap to prevent pounding as compared to those with water tanks attached to top floor under seismic excitations.

좁은 간격의 두 벽면 사이에서의 메탄-공기 예혼합 화염 전파에 벽면 상태가 미치는 영향 (The Effect of Wall Condition on the Methane-air Premixed Flame Propagation between Narrow Two Walls)

  • 최원영;권혁모;이대훈;권세진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.37-41
    • /
    • 2004
  • Quenching phenomena is one of major concern in development of millimeter or sub-millimeter scale micro combustor for the size of the combustor is near extinction condition. In this work we focused on the effect of combustor wall condition that was parameterized by Perovskite LSC($La_{0.8}$$Sr_{0.2}$$CoO_3$) redox catalyst. The experiment was done by variable gap-width 2D wall equipment. The flame was produced by premixed methane-air jet issuing from millimeter-scale slot burner and it propagated through the narrow gap of the walls. By comparison of flame behaviour near catalyst-coated wall and simple glass wall, we investigated the effect of possible surface reaction on quenching phenomena. The flame between two plates was observed where the gap of the plates was reduced stepwise from 20mm to a distance of quenching occurrence. The two flames with and without surface modification were almost same by observation. But the gap for the occurrence of quenching was increased between catalyst-coated wall. So we concluded that surface reaction close to combustor wall has a negative effect on micro combustion.

  • PDF