• Title/Summary/Keyword: gap size

Search Result 1,113, Processing Time 0.026 seconds

Prediction of the Ability of a Viscous Fluid Damper with Respect to Change of the Size of the Damper (점성 유체 감쇠기의 크기 변화에 따른 성능 변화 예측)

  • Park, Hwa-Yong;Yun, Jong-Min;Yoo, Seong-Hwan;Kim, Chang-Yeol;Lee, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • To reduce the vibration in industrial settings, the viscous fluid dampers have been widely used. Since the damper shows a viscoelastic behavior, many methods to predict the behavior have been investigated. But the methods did not consider a change of damper size that is important factor for practical design engineer. In this study, to predict a change of damper ability with respect to a change of damper size, the dynamic experiment were conducted with fixed aspect ratio and gap. The damping coefficient at zero frequency was computed through theoretical and experiment approach in order to fit the experimental results using fractional derivative Maxwell model.

Experimental Study on the Size Effect and Formability of Sheet Materials in Microscale Deep Drawing Process (마이크로 딥 드로잉 공정에서 박판소재의 크기효과 및 성형성에 관한 실험적 연구)

  • Nam, Jung Soo;Lee, Sang Won;Kim, Hong Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.9
    • /
    • pp.793-798
    • /
    • 2015
  • This study investigates the effects of the size of copper sheets on the plastic deformation behavior in a microscale deep drawing process. Tensile tests are conducted on the copper sheets to study the flow stress of the materials with different grain sizes before carrying out the microscale deep drawing experiments. After the tensile tests, a novel desktop-sized microscale deep drawing system is used to perform the microscale deep drawing process. A series of microscale deep drawing experiments are subsequently performed, and the experimental results indicate that an increase in the grain size results in the reduction of the deformation load of the copper sheets due to the effects of the surface grain. The results also show that the blank holder gap improves both the formability of copper sheets and the material flow.

Simulation of tissue differentiation around acetabular cups: the effects of implant-bone relative displacement and polar gap

  • Mukherjee, Kaushik;Gupta, Sanjay
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.95-109
    • /
    • 2014
  • Peri-acetabular bone ingrowth plays a crucial role in long-term stability of press-fit acetabular cups. A poor bone ingrowth often results in increased cup migration, leading to aseptic loosening of the implant. The rate of peri-prosthetic bone formation is also affected by the polar gap that may be introduced during implantation. Applying a mechano-regulatory tissue differentiation algorithm on a two-dimensional plane strain microscale model, representing implant-bone interface, the objectives of the study are to gain an insight into the process of peri-prosthetic tissue differentiation and to investigate its relationship with implant-bone relative displacement and size of the polar gap. Implant-bone relative displacement was found to have a considerable influence on bone healing and peri-acetabular bone ingrowth. An increase in implant-bone relative displacement from $20{\mu}m$ to $100{\mu}m$ resulted in an increase in fibrous tissue formation from 22% to 60% and reduction in bone formation from 70% to 38% within the polar gap. The increase in fibrous tissue formation and subsequent decrease in bone formation leads to weakening of the implant-bone interface strength. In comparison, the effect of polar gap on bone healing and peri-acetabular bone ingrowth was less pronounced. Polar gap up to 5 mm was found to be progressively filled with bone under favourable implant-bone relative displacements of $20{\mu}m$ along tangential and $20{\mu}m$ along normal directions. However, the average Young's modulus of the newly formed tissue layer reduced from 2200 MPa to 1200 MPa with an increase in polar gap from 0.5 mm to 5 mm, suggesting the formation of a low strength tissue for increased polar gap. Based on this study, it may be concluded that a polar gap less than 0.5 mm seems favourable for an increase in strength of the implant-bone interface.

CHANGES OF MARGINAL ADAPTATION TO THE CAVITY FLOOR OF LIGHT-CURED GLASS IONOMER CEMENT BASE AFTER APPLICATION OF A COMPOSITE RESTORATION (복합레진 적용에 따른 광중합형 글라스아이오노머 시멘트의 변연 적합도의 변화)

  • Lee, Gye-Young;Lee, Kwang-Won;Park, Soo-Joung
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.136-146
    • /
    • 1999
  • The purpose of this study was to estimate the changes of marginal adaptation to the cavity floor of light-cured glass ionomer cement base after application of a composite restoration. Eighty non-carious extracted human molars were used in the present study. Circular cavities were prepared on the center of the exposed dentin surface to 0.5mm, 1.0mm, 1.5mm, 2.0mm in depth and the prepared cavities were pretreated with Dentin conditioner and filled with Fuji II LC(GC Int. Co., Japan). They randomly assigned into 3 groups according to the difference in application of a composite restoration; Group 1(control group): only glass ionomer base, Group 2: The application of a composite restoration surrounded by dentin with class I cavity over glass ionomer base after conventional dentin bonding to the exposed dentin and glass ionomer base, Group 3: The application of composite restoration not-surrounded by dentin over glass ionomer base after conventional dentin bonding to the exposed dentin and glass ionomer base. To examine the interface between cavity floor and light-cured glass ionomer cement base, each groups were sectioned vertically through the center of restorations with diamond saw and the gap size(${\mu}m$) of interface measured by SEM. The results were analyzed by using One Way ANOVA. The results were as follows: 1. Good adaptation between glass ionomer cement base and cavity floor was showed in specimens with 0.5mm, 1.0mm depth base of control group. But in specimens with 1.5mm, 2.0mm depth base of control group, the gap was measured about $15{\mu}m$, $40{\mu}m$ respectively. 2. Gap size in group 2 was significantly higher than that in control group(P<0.05). 3. Gap size in group 3 was significantly higher than that in control group and group 2(P<0.05). 4. It was possible to observe the good adaptation between glass ionomer cement base and dentin which was intermediated with 4-10${\mu}m$ hybrid layer in specimens with 0.5mm, 1.0mm depth base of control group. Cohesive fracture within cement base was observed in all specimens which had the gap between glass ionomer cement base & dentin. 5. It was possible to observe the gap formation between cement base and bonding agent and between composite resin and dentin in all specimens of group 2.

  • PDF

A Numerical Study on Dynamic Characteristics of Counter-Rotating Rigid/Deformable Rolls in Press Contact (압착되어 회전하는 강체/변형 롤의 동적 특성에 관한 수치해석 연구)

  • Lee, Moon-Kyu;Lee, Sang-Hyuk;Hur, Nahm-Keon;Seo, Young-Jin;Kim, In-Cheol;Lee, Sung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.869-876
    • /
    • 2011
  • It is important to analyze the dynamic behavior of counter-rotating rigid/deformable rolls in the roll-coating process, because the stability of the process is affected by the dynamic characteristics. In the present study, the effects of material property, angular velocity, and gap size on the contact pressure and contact shape of the deformable roll are numerically investigated. The behavior of two rolls with a negative gap was analyzed using the finite element method, and the material property of the deformable roll was applied with the Mooney-Rivlin coefficients of the hyper-elastic model. The contact shape is affected by the gap size, and the contact pressure mainly depends on the stiffness of the deformable roll and the gap size. To maintain a negative gap between two rolls, controls such as load and displacement controls must be used. The results indicate that displacement control can reduce the instability.

A Novel Air-Bridge Type Gate-Data Line Inter-Crossing to Reduce Signal Delay for Large Size AMLCD (대면적 AMLCD의 신호 지연 감소를 위해 Air-gap을 갖는 게이트-데이터 라인 교차 구조)

  • Park, Jin-Woo;Kang, Ji-Hoon;Lee, Min-Cheol;Han, Min-Koo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.768-772
    • /
    • 1999
  • A new TFT-LCD panel with air-bridge type gate to data line inter-crossing has been proposed and its characteristics have been measured. The proposed structure has air-gap between gate and data line inter-crossing. This air-bridge TFT-LCD panel has very small capacitance between gate and data line. The new panes structure achieves 9 times fast signal propagation compared with conventional panel, which enables to have enough design margin for 20-inch diagonal and larger size UXGA panel. We have examined thermal and mechanical durability of new panel to verify applicability for commercial AMLCD production. After TEOS and polyimide passivation, this panel withstood a thermal stress at $250^{\circ}C$ and a mechanical stress during the rubbing process.

  • PDF

The Analysis of Gravity Mura Induced in Patterned Spacer Color Filter on Large Size LCD (대 면적 LCD에서 Patterned Spacer Color Filter 사용 시 발생하는 중력무라 분석)

  • Choi, S.;Jeong, Y.H.;Kim, M.S.;Kim, G.H.;Kim, H.Y.;Kim, S.Y.;Lim, Y.G.
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.8
    • /
    • pp.871-874
    • /
    • 2004
  • In recent, it is said that the trend of LCD is direction to pursue high qualities like as high transmittance, high contrast ratio, wide viewing angle, fast response time, and so on. Especially, it is known that these qualities are essential to large size LCD like as LCD TV and we can realize them through to uniform cell gap and deep black state. Until now, the ball spacer has been used to control of uniform cell gap. However, the existence of ball spacer inside the cell causes the deformation of the liquid crystal molecules and damage to alignment layer. Such a deformation of the liquid crystal causes light-leakage in the dark state, which lowers contrast ratio of the display. Nowadays, this problem has been solved by using Patterned Spacer on Color Filter. but Side Effect just as gravity mura has been induced. In this paper, we studied the mechanism on gravity mura in case of using patterned spacer on color filter.

Study on the characteristics of the plasma induced by lap-joint $CO_2$ laser welding of automotive steel sheets (자동차용 강판의 겹치기 $CO_2$ 레이저 용접에서 발생되는 플라즈마 특성에 관한 연구)

  • 남기중;박기영;이경돈
    • Laser Solutions
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 2002
  • In order to investigate the characteristics of the plasma induced by lap-joint CO$_2$ laser welding of automotive steel sheets, the effects of welding speed, shield gas flow rate, gap size, and laser beam defocus to plasma intensity emitted from keyhole have been investigated. The plasma light is measured by fiber and photodiode. Also, the plasma images were captured by the high speed digital camera in 1000frames/sec in order to correlate the plasma light signal with plasma pattern. From the results, it is observed that the difference of the plasma intensity for between the deep penetration and partial penetration exists from 1.2 to 2 times. The plasma light intensity decreased in case of the deep penetration Is observed due to the exhausting of the plasma gas under the sheet. On the other hand, under the conditions of the deep penetration, the plasma intensity is significantly increased by controling the conditions decreasing the penetration depth. It was specially founded that the effect of 0.3mm gap size at partial penetration condition is approximately similar to deep penetration in 0mm gap. It is concluded that the plasma intensity is able to evaluate the penetration depth in lap-joint welding and appears to offer the most straightforward correlation to the welding process.

  • PDF

Design of the Miniaturized Ultra-WideBand(UWB) Filter of the Shorted Open Gap Ring Structure combined with the interdigital Line (단락 개방간극 링 구조와 인터디지틀 선로의 결합형 소형 초광대역 여파기 설계)

  • Oh, Seunghun;Kim, Koon-Tae;Kang, Seong-In;Lee, Jeong-Hyeok;Han, Jun-Hee;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1706-1711
    • /
    • 2013
  • This paper presents the filter of a resonator comprising a shorted open gap ring(SOGR) and interdigital lines. The proposed filter has the ultra wideband characteristic operating from 3 GHz to 10.5 GHz. In order to achieve the remarkable improvement in the size-reduction of the overall filter structure, only one cell of the SOGR with the inter-digital lines is adopted. It is shown that this filter has the size of $18mm{\times}15mm$ using a metamaterial, the fractional bandwidth over 100%, the insertion loss much less than 1dB, an acceptable return loss performance in the results.

ASSESSMENT OF CORE BYPASS FLOW IN A PRISMATIC VERY HIGH TEMPERATURE REACTOR BY USING UNIT-CELL EXPERIMENT AND CFD ANALYSIS (단위-셀 실험과 전산유체해석을 통한 블록형 초고온가스로의 노심우회유량 평가)

  • Yoon, S.J.;Jin, C.Y.;Kim, M.H.;Park, G.C.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • An accurate prediction of the bypass flow is of great importance in the VHTR core design concerning the fuel thermal margin. Nevertheless, there has not been much effort in evaluating the amount and the distribution of the core bypass flow. In order to evaluate the behavior and the distribution of the coolant flow, a unit-cell experiment was carried out. Unit-cell is the regular triangular section which is formed by connecting the centers of three hexagonal blocks. Various conditions such as the inlet mass flow rate, block combinations and the size of bypass gap were examined in the experiment. CFD analysis was carried out to analyze detailed characteristics of the flow distribution. Commercial CFD code FLUENT 6.3 was validated by comparing with the experimental results. In addition, SST model and standard k-$\varepsilon$ model were validated. The results of CFD simulation show good agreements with the experimental results. SST model shows better agreement than standard k-$\varepsilon$ model. Results showed that block combinations and the size of the bypass gap have an influence on the bypass flow ratio but the inlet mass flow rate does not.