• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.029 seconds

A Study on the Selection of Measuring Mode in the Permittivity Measurement Using a Circular Cylindrical Cavity (원통형 공진기를 이용한 유전율 측정방법에서 측정모드 선택에 관한 연구)

  • Lee, Won-Hui;Kang, Soon-Kuk;Choi, Hong-Ju;Hur, Jung;Lee, Sang-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.218-226
    • /
    • 1999
  • This paper describes resonant mode selection with which the relative permittivity can be measured exactly. To measure the relative permittivity, a circular cylindrical cavity filled with dielectric material is used. When the circular cylindrical cavity is filled with the dielectric material, the air gap occurs on account of machining error. Accurate relative permittivity can be obtained by using less sensitive mode in resonant frequency variation by the air gap. As a result, Average 0.009% resonant frequency variation in the vertical and the radial direction appears at $TE_{011}$ mode. It is interesting that the frequency variation by the air gap at $TE_{011}$ mode turns out to be the least sensitive.

  • PDF

A Study on Characteristics of Skin Resistance Variability(SRV) in the Traffic Accident Patients Prescribed Dangkisoo-san(Dangguixu-san) (당귀수산을 처방받은 교통사고환자의 피부저항변이도 특성에 관한 연구)

  • Kim, Eu-Gene;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.3
    • /
    • pp.119-132
    • /
    • 2008
  • Objectives : The purpose of this study was to know the characteristics of Skin Resistance Variability(SRV) in the traffic accident patients prescribed Dangkisoo-san(Dangguixu-san). Methods : 65 traffic accident patients were selected from those who took the Skin Resistance Variability(SRV) test in Oriental Medical Hospital of Sang-Ji University from March 2007 to January 2008. The traffic accident patients were prescribed Dangkisoo-san(Dangguixu-san). Mean values of factor AA on skin resistance variability of the traffic accident patients were analyzed. Results and Conclusions : The mean values of electrodermal activity of preexamination was higher than those of postexamination in all areas except 3 area in 2nd measurement. In most cases, the gap of electrodermal activity between preexamination and postexamination within the female group was higher than those of the male group. In most cases, the gap of electrodermal activity between preexamination and postexamination within the more than 21 days group was higher than those of the 20days and less group. In most cases, the gap of electrodermal activity between preexamination and postexamination within the 36 years old group was higher than those of the 35years old and less group. Dangkisoo-san(Dangguixu-san) will be more effective for acute and strong traffic accident patients than chronic and weak traffic accident patients. So, further studies will be needed.

An Assessment on the Hydraulic Characteristics of a Multi-dimensional Model in Response to Measurement Resolution and Spatial Interpolation Methods (지형자료의 해상도와 공간보간기법에 따른 다차원 수리모형의 유출 특성 평가)

  • Ahn, Jung-Min;Park, In-Hyeok
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.1
    • /
    • pp.43-51
    • /
    • 2012
  • Due to the increasing demand to utilize water fronts and water resource effectively, a multi-dimensional model that provides detailed hydraulic characteristics is required in order to improve the decision making process. An EFDC model is a kind of multi-dimension model, and it requires detailed 3D (3-dimensional) terrain in order to simulate the hydraulic characteristics of stream flow. In the case of 3D terrain creation, especially river reaches, measurement resolution and spatial interpolation methods affect the detailed 3D topography which uses input data for EFDC simulation. Such results make hydraulic characteristics to be varied. This study aims to examine EFDC simulation results depending on the 3D topographies derived by separate measurement resolution and spatial interpolation methods. The study area is at the confluence of the Nakdong and Kuemho Rivers and the event rain implemented was Typhoon Ewiniar in 2006. As a result, in the case of the area-elevation curve, the difference by means of the interpolation methods was significant when applying the same measurement resolution, except at 160m resolution. Furthermore, when the measurement resolution was 80m or above, the difference in a cross-section was occurred. Meanwhile, the water level changes between interpolation methods were insignificant by the measurement resolution except when the Kriging method was used for the 160m measurement data. Velocity changes emerged according to the interpolation methods when measurement resolution was 80m or above and the Kriging method resulted in a velocity that had a considerable gap in relation to the results from other methods at a measurement resolution of 160m.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

Analysis of the trend of mathematical achievement of students according to school grade change in TIMSS (TIMSS 수학 평가에서 학교급 전환에 따른 학생들의 학업성취 변화 추이 분석)

  • Kwon, Jeom-rae
    • Communications of Mathematical Education
    • /
    • v.38 no.2
    • /
    • pp.121-144
    • /
    • 2024
  • This study analyzes how the academic achievement of students in Korea changes as they transition from 4th grade of elementary school to 2nd grade of middle school, considering that the 4th graders in the previous TIMSS cycle become 2nd graders in the next cycle. In particular, this study selects and compares the eight main countries in the TIMSS math evaluation (Korea, Singapore, Taiwan, Japan, USA, UK, Australia, and Russia) to analyze the trend of change in academic achievement of Korean students according to school grade transition. The trend of change in academic achievement of students was analyzed not only overall but also by content area (number, geometry and measurement, data representation (data and probability/data and probability), gender, and regional scale. The analysis focused on the average score and the proportion of students by achievement level. The results of the study are as follows. First, there was no significant change in the average score of Korean students' academic achievement as the school grade transitioned, but the achievement gap widened in terms of the proportion by achievement level. Second, there were differences in students' academic achievement by content area according to school grade transition, and the pattern differed depending on the evaluation cycle. Third, there was a significant gap in students' math academic achievement depending on gender and regional scale of school location. This study reveals that the achievement gap among students in our country widens as they transition between school levels. The gap is found to vary in terms of achievement level, math content area, student gender, and school location. To alleviate these disparities, more substantial research and support are proposed in addition to policy implementation by the government or provincial offices of education.

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.

Technological Innovation Orientation: Conceptualization, Measurement, and Its Relationship to Performance (기술혁신지향성: 개념화, 측정 및 성과와의 관계)

  • Moon, Chang-Ho
    • Journal of Technology Innovation
    • /
    • v.21 no.2
    • /
    • pp.255-283
    • /
    • 2013
  • Despite its theoretically and practically important value, the concept of technological innovation orientation has not been theoretically well established and thus has not been operationalized appropriately in previous studies. Given such a gap in prior research regarding technological innovation orientation, this study proposed a refined conceptualization of technological innovation orientation and a new measurement instrument for capturing the refined concept of technological innovation orientation. More specifically, this study conceptualized technological innovation orientation as having two components of proclivity to technological leadership and openness to technological innovation and developed a measurement instrument for operationalizing the two-dimensional concept of technological innovation orientation. Based on the proposed conceptualization and operationalization of technological innovation orientation, this study also investigated the relationship between technological innovation orientation and firm performance. Based on a sample of 97 Korean IT SMEs, the results demonstrated a high reliability and validity for the measurement instrument developed to operationalize the two-dimensional technological innovation orientation. The results further revealed that technological innovation orientation is positively related to technological innovation performance and that technological innovation performance positively mediates the relationship between technological innovation orientation and financial performance.

  • PDF

The scanned point-detecting system for three-dimensional measurement of light emitted from plasplay panel (플라즈마 디스플레이 패널에서 방출되는 광의 3차원 측정을 위한 Scanned Point-Detecting System)

  • 최훈영;이석현;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.103-108
    • /
    • 2001
  • In this paper, we designed and made the scanned point detecting system for 3-dimensional measurement of the light emitted from plasma display panel (PDP) , and we measured and analyzed 3-dimensional light emitted from a real PDP by using this scanned point detecting system. The scanned point detecting system has a point detector with a pinhole. The light emitted from the source at the in-focus position can pass through the pinhole and be collected by detector. The light from other sources at outof-focus positions is focused at points in front of or behind the pinhole, and thus it is intercepted by the pinhole. Therefore, we can detect light information from a particular point of a PDP cell of 3-dimensional structure. We know the electric field distribution inside the PDP cell from the 3-dimensionallight intensity distribution measured by using the scanned point detecting system. As the Z axial measurement increases, the intensity of light detected increases and intensity of light detected on the inside edge of the ITa electrode is larger than outside edge of the ITa eletrode and gap of the ITa electrodes. Also, as the measurement point moves from one barrier rib to another, the detected light is weaker near to the barrier ribs than at the center between the barrier ribs. The emitted light is concentrated at the center between barrier ribs. ribs.

  • PDF

A Method for Generation of Grinding Map based on Automatic Mold Measurement (금형 자동측정에 의한 사상맵 생성)

  • Jeoung, Nam-Yeoung;Cho, Jin-Hyung;Oh, Hyun-Seung;Lee, Sae-Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.248-255
    • /
    • 2018
  • Ensuring the quality of molds is one of the major issues in mass production. In general, securing the quality of the molds is achieved by repeating grinding and die spotting after machining the molds based on engineer's decision. However, this heuristic method is affected by the engineer's skill and working environment. Therefore, a lot of time and resources are needed in order to ensure quality. In this study, ensuring the quality of molds using grinding map which is generated using automatic measurement is proposed. An automatic measuring system based on CMM (Coordinate Measuring Machine) is developed for measuring the molds. This system generates the measurement path automatically using the 3D CAD model of products. CAD (ComputerAided-Design), CAM (Computer-Aided-Manufacturing), and CAQ (Computer-Aided-Quality) technology is integrated using DMIS (Dimensional Measuring Interface Standard) format in the automatic measuring system. After measuring the molds, a grinding map is generated using the gap between the CAD model and measured values of mold. The grinding map displays the machining tendency and the required amount of grinding with values on a 3D map. Therefore, the quality of molds can be ensured with exactness and quickness based on the grinding map. This study shows that integrating the planning, measuring, and analyzing based on computer technology can solve the problem of quality assurance of mold using the proposed method, therefore the productivity can be increased.

The Scale Development of Consumer's Charity Impulse : Focusing on Donation Behavior toward Non-profit Organization (소비자의 자선적 충동에 관한 측정도구의 개발 - 비영리단체에 대한 기부행위를 중심으로 -)

  • Ock, Jung-Won;Seo, Hae-Jin
    • Management & Information Systems Review
    • /
    • v.33 no.3
    • /
    • pp.1-19
    • /
    • 2014
  • Main research question of this study is based on situational gap between donation motivation and behaviour in non-profit organization. However, researches investigating the gap were limited. Therefore, this study examined components of psychological variables. Specially, we proposed the variables about consumer's impulsive motivation or behavior on impulse literature in donation toward non-profit organization. This study conducted a scale development to measure consumer's charity donation impulse based on non-conscious viewpoint. For the development of measurement tool for charity donation impulse, we conducted two stages of research process. First, the measurement items of charity donation impulse were developed through FGI and in-depth interview on experts. Secondly, the factor analysis was performed, and then some items were eliminated through this analysis. As a result, we found the final scale with 26 items, which were named as evaluation sensitivity charity impulse, reward sensitivity charity impulse, functional impulse, non-planning charity impulse. These results showed that the measurement items developed in this study were confirmed to be useful tools for measuring charity donation impulse.

  • PDF