• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.023 seconds

Evaluating the Accuracy of an OpenCV-Based Length Measurement Algorithm: The Impact of Checkerboard Type and Capturing Conditions (체커보드 종류 및 촬영조건에 따른 OpenCV 기반 길이측정 알고리즘 정확도 분석)

  • Kim, Hyeonmin;Kwon, Woobin;Kim, Harim;Kim, Hyungjun;Song, Seung Ho;Cho, Hunhee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.133-144
    • /
    • 2024
  • The OpenCV-based length measurement algorithm is anticipated to be effective for length measurement inspection tasks, providing objective inspection outcomes. Nonetheless, there is a notable gap in research regarding the influence of various checkerboard types and capturing conditions on the algorithm's accuracy in real-world construction settings. Consequently, this study proposes a methodology employing an OpenCV-based length measurement algorithm and checkerboard for digital construction inspection tasks. The findings suggest that using a checkerboard with square sizes of A4 or larger, and 50mm or larger, is optimal for capturing distances and angles within 4m and 90°, respectively, when deploying the algorithm. These insights are anticipated to provide practical guidelines for professionals conducting digital-based length measurement inspections.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Application to the Flow in HDD Using PIV Measurement (HDD내 유동장에 대한 PIV 계측 기술의 적용)

  • 공대위;주원구;도덕희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.742-747
    • /
    • 2004
  • Hard disk drives (HDD) in computer are used extensively as data storage capacity. PIV measurement system was used fur 2-dimensional visualization of the unsteady flow between co-rotating disks in air both with a shroud and both with a actual-like case. Geometric parameters are gap height (H) between disks in the case of shroud. The lobe- structured boundary between inner region and outer region was visualized, and the number of dominant vertices was determined clearly. It is found from flow visualization that the number of vortex cells can be correlated with Reynolds number based on H which is defined as R $e_{H}$ =ΩRH/v ranging from 7.96$\times$10$^2$ to 1.43$\times$10$^4$, and decreases as the disk speed increases. In the case of a actual-like case, the boundary between inner region and outer region appears cleary when head position located at outer diameter with no damper. It is detected with a case of head position middle diameter that the tip wake is generated behind HGA using PIV measurement and calculation.n.

  • PDF

Development of a Cardiovascular Index That Estimates Cardiovascular Health Degree by Survey and Noninvasive Examination (설문과 비침습적 검사를 통하여 심혈관계 건강 정도를 알려주는 심혈관지수의 개발)

  • Lee, Chong Sun;Chung, In Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.459-466
    • /
    • 2014
  • An index was developed that estimates cardiovascular health degree with easily available physiological information such as survey and noninvasive measurement. The survey score was calculated by utilizing questions related to personal disease history, self-feeling, and management state. The measurement score was calculated using physiological parameters such as blood pressure, accelerated plethysmograph(APG), and heart rate variability(HRV), and augmentation index(AI). In order to evaluate effectiveness of the cardiovascular index and modify weighting factors used in each item, a clinical trial was done in a general hospital. The cardiovascular index showed a clear correlation of 0.685 with the doctor's score on the cardiovascular health degree. The correlation between the self-estimated score and doctor's score was as low as 0.217. The large gap between these two scores demonstrated necessity of more objective tools like the cardiovascular index. The cardiovascular score showed a significant difference between normal persons and patients suffering hypertension or diabetes. (p=0.000).

Characterization of a Micro-Laser-Plasma Electrostatic-Acceleration Hybrid-Thruster

  • Akira Igari;Masatoshi Kawakami;Hideyuki Horisawa;Kim, Itsuro ura
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.271-277
    • /
    • 2004
  • As one of the concepts of the laser/electric hybrid propulsion system, a feasibility study on possibilities of electrostatic acceleration of a laser ablation plasma induced from a solid target was conducted. Energy distributions of accelerated ions were measured by a Faraday cup. A time-of-flight measurement was also conducted for ion velocity measurement. It was found that an average speed of ions from a pure laser ablation in this case was about 20 km/sec for pulse energy of 40 $\mu$J/pulse with pulse width of 250 psec. On the other hand, through an electrostatic field with a + I ,000 V electrode, the speed could be accelerated up to 40 km/sec. It was shown that the electrode with positive potential was more effective than that with negative potential for positive-ion acceleration in laser induced plasma, or pulsed plasma, in which ions were induced with the Coulomb explosion following electrons. In addition, the ion-acceleration or deceleration strongly depended on conditions of pairs of inner diameter and electrodes gap.

  • PDF

Usability assessment of thermoplastic Bolus for skin VMAT radiotherapy (피부 병변에 대한 VMAT 치료 시 열가소성 bolus의 유용성 평가: case review)

  • Kim, Min Soo;Kim, Joo Ho;Shin, Hyun Kyung;Cho, Min Seok;Park, Ga Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.85-92
    • /
    • 2020
  • Purpose: To find out the advantages of thermoplastic bolus compared to conventional bolus, which is mainly used in clinical practice, We evaluated Two cases in terms of dose and location reproducibility to assess Usability of thermoplastic Bolus for skin VMAT radiotherapy. Materials and Methods: Two patient's treated with left breast skin lesion were simulated using thermoplastic Bolus and planned with 2arc VMAT. the prescription dose was irradiated to 95% or more of the target volume. We evaluated The reproducibility of the bolus position by measuring the length of the air gap in the CBCT (Cone Beam CT) image. to evaluate dose reproducibility, we compared The dose distribution in the plan and CBCT and measured in vivo for patient 2. Results: The difference between the air gap in patient 1's simulation CT and the mean air gap (M1) during 10 treatments in the CBCT image was -0.42±1.24mm. In patient 2, the difference between the average air gap between the skin and the bolus (M2) during 14 treatments was -1.08±1.3mm, and the air gap between the bolus (M3) was 0.49±1.16. The difference in the dose distribution between Plan CT and CBCT was -1.38% for PTV1 D95 and 0.39% for SKIN (max) in patient 1. In patient 2, PTV1 D95 showed a difference of 0.63% and SKIN (max) -0.53%. The in vivo measurement showed a difference of -1.47% from the planned dose. Conclusion: thermoplastic Bolus is simpler and takes less time to manufacture compared to those produced by 3D printer. Also compared to conventional bolus, it has high reproducibility in the set-up side and stable results in terms of dose delivery.

A study on Electronic Properties of Passive Film Formed on Ti

  • Kim, DongYung;Kwon, HyukSang
    • Corrosion Science and Technology
    • /
    • v.2 no.5
    • /
    • pp.212-218
    • /
    • 2003
  • Electronic properties of passive films formed on Ti at film formation potentials $(E_f)V_{SCE}$ in pH 8.5 buffer solution and in an artificial seawater were examined through the photocurrent measurement and Mott-Schottky analysis. The passive films formed on Ti in pH 8.5 buffer solution exhibited a n-type semiconductor with a band gap energys $(E_g);E_g^{n=2}=3.4$ eV for nondirect electron transition, and $E_g^{n=0.5}=3.7$ eV for direct electron transition. These band gap values were almost same as those for the passive films formed in artificial seawater, indicating that chloride ion ($Cl^-$ in solution did not affect the electronic structure of the passive film on Ti. $E_g$ for passive films formed on Ti were found to be greater than those ($E_g^{n=0.5}=3.1$ eV, $E_g^{n=2}=3.4$) for a thermal oxide film formed on Ti in air at $400^{\circ}C$. The disorder energy of passive film, determined from the absorption tail of photocurrent spectrum, was much greater than that for the thermal oxide film farmed on Ti in air at $400^{\circ}C$. The greater $E_g$ and the higher disorder energy for the passive film compared with those for the thermal oxide fIlm suggest that the passive film on Ti exhibited more disorded structure than the thermal oxide film. The donor density (about $2.4{\times}10^{20}cm^{-3}$) for the passive film formed in artificial seawater was greater than that (about $20{\times}10^{20}cm^{-3}$) formed in pH 8.5 buffer solution, indicating that $Cl^-$ increased the donor density for the passive film on Ti.

A study of Development and Management on ASEAN Women's ICT Development Index and Measurement (ASEAN 여성의 ICT 발전 지수 개발과 측정에 대한 연구)

  • Youn, Mi-Hee;Kim, Dongwon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.181-187
    • /
    • 2016
  • In this paper, we develop the Women's Information and Communications Technology Development Index (WIDI) framework for the Association of Southeast Asian Nations (ASEAN) Member States. While there are a number of global ICT indices, there are no standard global data metrics for ICT gender-related statistics in developing countries. Therefore, this research has been conducted by the Asia Pacific Women's Information. This study referenced some of the major global ICT indices and created a framework that used their basic structure and included the various measurement factors such as socio-cultural factors element and ICT policy for woman. The WIDI framework is supported by a back-end survey that was designed by the research team and reviewed by ASEAN taskforce members. Through WIDI, we can compare ICT development status and gender information gap and measure the national information gap. By presenting the basis for policy decisions on eliminating gender disparitie can help improve the social status of women.

Temperature dependence of photocurrent for the AgInS2 epilayers grown by hot wall epitaxy (Hot Wall Epitaxy 방법에 의해 성장된 AgInS2 박막의 광전류 온도 의존성)

  • Park, Chang-Sun;Hong, Kwang-Joon;Lee, Sang-Youl;You, Sang-Ha;Lee, Bong-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • A silver indium sulfide ($AgInS_{2}$) epilayer was grown by the hot wall epitaxy method, which has not been reported in the literature. The grown $AgInS_{2}$ epilayer has found to be a chalcopyrite structure and evaluated to be high quality crystal. From the photocurrent measurement in the temperature range from 30 K to 300 K, the two peaks of A and B were only observed, whereas the three peaks of A, B, and C were seen in the PC spectrum of 10 K. These peaks are ascribed to the band-to-band transition. The valence band splitting of $AgInS_{2}$ was investigated by means of the photocurrent measurement. The crystal field splitting, ${\Delta}cr$, and the spin orbit splitting, ${\Delta}so$, have been obtained to be 0.150 eV and 0.009 eV at 10 K, respectively. And, the energy band gap at room temperature has been determined to be 1.868 eV. Also, the temperature dependence of the energy band gap, $E_{g}$(T), was determined.

Comparative evaluation of marginal and internal fit of three-unit Co-Cr frameworks fabricated by metal milling and direct metal laser sintering methods (금속 밀링과 직접 금속 레이저 소결 방식으로 제작한 3본 코발트-크롬 구조물의 변연 및 내부 적합도 비교 평가)

  • Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.81-89
    • /
    • 2020
  • Purpose: This in vitro study was conducted to evaluate the marginal and internal fit of three-unit Co-Cr frameworks fabricated by computer-aided metal milling and direct metal laser sintering(DMLS) systems in comparison to conventional casting method. Methods: Three-unit Co-Cr frameworks were fabricated by conventional wax up with casting(CWC), computer-aided metal milling(MM) and direct metal laser sintering(DMLS)(n=10 each). The marginal and internal fit of specimens were examined using a light-body silicone impression material. The thickness of light-body silicone was measured at eight reference points each, divided in the mesio distal and bucco lingual directions. All measurements were conducted by a stereomicroscope. Digital photos were taken at 150× magnification and then analyzed using a measurement software. The Kruskal-Wallis test and Bonferroni correction were used for analyzing the results. Results: The mean(SD) is ㎛ for fabrication methods, the mean marginal fit were recorded respectively, DMLS 39(27), followed by CWC 63(38), MM 220(128). and the mean internal fit CWC 95(47), DMLS 116(49), MM 210(152). In addition, the largest gap was found in the occlusal surface area among the internal measurement areas of all groups. Conclusion: As a result, the direct metal laser sintering method showed better marginal and internal fit than the metal milling method. The marginal and internal fit were statistically different according to the three fabrication methods(p<0.001). Except the MM group, the marginal fit of the CWC and DMLS groups was below the clinical standard of 120 ㎛. Based on the results of this study, it can be applied to clinical use in the future.