• 제목/요약/키워드: gap k-joint

검색결과 129건 처리시간 0.023초

연강 판재의 맞대기 용접에서 아크에 작용하는 자기력의 해석 (Analysis of Electro-Magnetic Force Acting on Arc Column in Butt-Joint Welding of Mild Steel Plate)

  • 배강열
    • Journal of Welding and Joining
    • /
    • 제23권4호
    • /
    • pp.73-80
    • /
    • 2005
  • Arc blow being occurred by Electro-Magnetic force(EMF) during the electric arc welding prevents the formation of a sound weldment. In this study, the effects of arc position, groove size, tack weld and base plate on the EMF in a butt-joint welding of mild steel plate are analyzed by a computer simulation based on the finite element method. The EMF can be numerically identified to be caused by a difference of the magnetic flux-density between ahead of and behind the arc in case that the workpiece locates asymmetrically around the uc. When there exists an air gap of groove ahead of the arc in the welding direction, the similar magnetic force has been producted regardless of the arc position and the gap size. The tack weld alleviates the magnetic force to about one fourth at the finish end of the workpiece. The magnetic force can be also significantly reduced with the base plate to about one fifth at the start end of the workpiece containing a tack weld.

Effect of flexion degrees in elbow joint on muscle activation of the extensor carpi radialis and biceps brachii muscles in healthy young adults

  • Kim, Gap-Cheol;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.120-124
    • /
    • 2016
  • Objective: Chronic lateral epicondylitis is a condition which becomes sore and tender on the lateral side of the elbow joint damaged from overuse and repetitive use of the extensor muscles of the forearm. The purpose of this study was to investigate the effects of flexion degrees in the elbow joint on extensor carpi radialis longus and brevis and biceps brachii muscles in individuals with healthy young adults. The main purpose of this study was to suggest the feasibility of optimal elbow angle during therapeutic eccentric exercise with resistance for strengthening of wrist extensors. Design: Cross-sectional study. Methods: Thirty health young adults (male 15, female 15) participated in this study. This study measured muscle activation in four different conditions of elbow flexion, $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, and $90^{\circ}$ during eccentric exercise with weight loading in wrist extensors, extensor carpi radialis longus and brevis and biceps brachii muscles using surface electromyography. Results: The muscle activation of extensor carpi radialis showed a negative relationship with the degrees of elbow joint flexion. With increasing elbow flexion angles, the ECRL muscle activation amount was significantly lower (p<0.05). In contrast, the muscle activation of the ECRB muscle activation amount was significanlty higher (p<0.05). Conclusions: This study suggests that the eccentric exercise of wrist extension with selected activation of wrist extensor muscles according to elbow flexion positions, and suggests that the extensor carpi radialis longus and brevis will need to be strengthened for preventing and treating chronic lateral epicondylitis regardless of degrees of elbow joint flexion.

레이저-회전 아크 하이브리드 용접공정의 개발 (Development of Laser-Rotating An Hybrid Welding Process)

  • 김철희;채현병;이창우;김정한;이세헌
    • Journal of Welding and Joining
    • /
    • 제24권1호
    • /
    • pp.88-92
    • /
    • 2006
  • Laser-rotating arc hybrid welding was introduced by combining $CO_2$ laser and rotating gas metal arc welding. While the arc rotation enhances the weld pool motion, it reduces the undercut formation which is one of most critical weld defects in the conventional laser-arc hybrid welding. This research investigated the bead characteristics according to the welding parameters such as frequency of rotation, welding voltage, shielding gas composition and interspacing distance between laser and we. The welding parameters were selected to reduce spatter generation and ensure sound weld beads fur bead welding and butt welding with various joint gaps. Gap bridging ability was improved, such that the sound weld beads were achieved for butt joint with up to 2mm joint sap, with no adjustment of CTWD(Contact tip-to-workpiece distance) and electrode diameter.

압축 및 내압을 받는 고무 오링의 기밀 성능 평가 (An evaluation on sealing performance of elastomeric O-ring compressed and highly pressurized)

  • 박성한;김재훈;김원훈
    • 한국정밀공학회지
    • /
    • 제26권2호
    • /
    • pp.86-93
    • /
    • 2009
  • Elastomeric O-rings have been the most common seals due to their excellent sealing capacity, and availability in costs and sizes. One of the critical applications of O-ring seals is solid rocket motor joint seal where the operating hot gas must be sealed during the combustion. This has long been a design issue to avoid the system failure. For laterally constrained, squeezed and pressurized condition, deformed shape of O-ring was measured by computed tomography method and CCD laser sensor, compared with numerical calculations. As clearance gap changes, sealing performance had been evaluated on peak contact stresses at top, bottom and side contact surfaces. As clearance gap increases, peak contact stresses and contact widths in top and side contact surfaces increase, and the asymmetry of stress distributions is promoted due to pressure increase. It is suggested that peak stress of bottom contact surface can be approximated by simple superposition of peak ones due to squeeze and pressure. Under pressurized condition, sealing performance is dependent on not peak stresses of bottom and side contact surfaces but that of top.

NO ROOT GAP HORIZONTAL BUTT-WELDING WITH MAG PROCESS

  • Woo, Wan-Chuck;Jang, Tae-Won;Lee, Jae-Won
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.425-429
    • /
    • 2002
  • It has been used many kinds of horizontal butt-welding methods at block-to-block erection stage in shipbuilding companies. For examples, some companies use conventional FCA W process with one side or both sides groove joint welding, others use carriage with torch holder type mechanized welding method. Although lots of efforts were done until now, some problems in quality and productivity still remain in ship's hull welding. In this study, we have attempted to raise productivity and quality on horizontal position of welding with following 3 items. 1) Prepare groove condition with no root gap for making easy fit-up work. 2) Develop improved MAG (100% $CO_2$ gas shielding) welding process with solid wire for making sound root bead from one side. 3) Develop and apply quite new automatic welding carriage. The stability of new welding process was confirmed by conducting mechanical tests of weldments to verify the soundness of weldments.

  • PDF

Severe bony ankylosis of the temporomandibular joint on one side and contralateral adhesion: A case report

  • Song, Ji-Young;Kim, Seong-Gon;Choi, Hang-Moon;Kim, Hyun Jung
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.103-108
    • /
    • 2015
  • Bony fusion between the mandibular condyle and skull base involves temporomandibular joint (TMJ) bony ankylosis. This condition might originate from trauma, infection, or systemic disease. TMJ adhesion can develop after synovial damage. Both TMJ ankylosis and adhesion lead to functional impairment and pain. Here, we present a case of a 50-year-old female who had bony ankylosis of the right TMJ and adhesion of the left TMJ. She had otitis media in the right ear. A large mass in the right TMJ was observed on computed tomograph. Magnetic resonance image showed a large fused bone mass with normal bone marrow in the right TMJ and flattening of the condyle with a thin disk in the left TMJ. Gap arthroplasty with temporal fascia was performed on the right TMJ, and discectomy, high condylectomy, and coronoidectomy were performed on the left TMJ. During a 2-year follow-up after surgery, the patient had no recurrence.

Morphological and Biomechanical Study of the Pulley System of the Thumb

  • Kim, Ji-Won
    • 한국전문물리치료학회지
    • /
    • 제12권4호
    • /
    • pp.33-40
    • /
    • 2005
  • The purpose of this study was to define more precisely the anatomy of the thumb flexor pulley system and to determine the relative contribution of each of the pulleys to the biomechanics of thumb motion at the metacarpophalangeal (MP) and interphalangeal (IP) joints. For this, 22 hands from 11 cadavers were used and randomly assigned to two groups. In the first group, the first annular (A1) pulley was cut first followed by the variable annular (Av) pulley and then the oblique pulley. In the second group, the oblique pulley was cut first followed by the, pulley and then the Av pulley. In 7 of 22 hands, it was a transverse structure parallel to the, pulley with a gap between the A1 and Av pulleys, referred to here as type I. In 9 hands, the A1 and Av pulleys were connected without any gap (type II). In 6 hands, the space between the A1 and Av pulleys were triangular in shape with fibers of the Av pulley converging toward the radial side (type III). In biomechanical study of both first and second experiments, there was no significant difference in MCP joint flexion between the all intact, A1 section, A1/Av section, A2 intact (A1/Av/oblique section), and no pulley configuration (p>.05). In occurring displacements less than 10 mm, there was no significant difference in IP joint flexion (p>.05). However, there was a significant decrease in IP joint flexion occurred in both 15 mm and 20 mm excursion (p<.05), when the oblique pulley was resected additionally after cutting the A1 and Av pulleys in first experiment, and when the A1 pulley was resected additionally after cutting the oblique pulley. According to the results, the injury of only the oblique pulley does not decrease thumb motion significantly. The oblique pulley injury with both the A1 and Av pulleys laceration decreased thumb motion significantly. The additional laceration of the A2 pulley does not decrease thumb motion.

  • PDF

Unilateral intraoral vertical ramus osteotomy and sagittal split ramus osteotomy for the treatment of asymmetric mandibles

  • Lee, Jee-Ho;Park, Tae-Jun;Jeon, Ju-Hong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권2호
    • /
    • pp.102-108
    • /
    • 2015
  • In surgery for facial asymmetry, mandibles can be classified into two types, rotational and translational, according to the required mandibular movements for surgery. During surgery for rotational mandibular asymmetry, a bilateral sagittal split ramus osteotomy (BSSRO) may cause a large bone gap between the proximal and distal segments as well as condylar displacement, resulting in a relapse of the temporomandibular joint disorder, especially in severe cases. The intraoral vertical ramus osteotomy has an advantage, in this respect, because it causes less rotational displacement of the proximal segment on the deviated side and even displaced or rotated condylar segments may return to their original physiologic position. Unilateral intraoral vertical ramus osteotomy (UIVRO) on the short side combined with contralateral SSRO was devised as an alternative technique to resolve the spatial problems caused by conventional SSRO in cases of severe rotational asymmetry. A series of three cases were treated with the previously suggested protocol and the follow-up period was analyzed. In serial cases, UIVRO combined with contralateral SSRO may avoid mediolateral flaring of the bone segments and condylar dislocation, and result in improved condition of the temporomandibular joint. UIVRO combined with contralateral SSRO is expected to be a useful technique for the treatment of rotational mandibular asymmetry.

저주기 피로부하에서 F82H 강 TIG 용접 접합부의 피로손상거동 (Fatigue Damage Behavior in TIG Welded Joint of F82H Steel under Low Cycle Fatigue Loading)

  • 김동현;박기원
    • Journal of Welding and Joining
    • /
    • 제33권6호
    • /
    • pp.42-48
    • /
    • 2015
  • Reduced activation ferritic/martensitic steels are recognized as the primary candidate structural materials for fusion blanket systems. Welding is an inevitable for breeding blanket for pressure tightness and radioisotope confinement. Especially, TIG welding was chosen for sealing because it has the largest gap allowance compared to the other welding methods, and its properties are controllable by feed wire and welding conditions. In this study, the low cycle fatigue test using two-type gage such as extensometer and strain gage was applied to the TIG welded joint of F82H steel, for evaluating fatigue damage accumulation behavior of the HAZs. As the result, the over-tempered HAZ have shown a higher fatigue damage accumulation compared with other materials at all the testing conditions.

종골 관절내 골절의 수술적 치료 후 임상 결과 -전산화 단층 촬영에 따른 분류 및 관혈적 정복 및 내고정 치료- (Result of Surgical Treatment of Intra-Articular Fractures of the Calcaneus - Based on CT Classification and Open Reduction and Internal Fixation -)

  • 김의순;서현모;이규민;최훈휘;문명상;이만희;최원태
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.238-249
    • /
    • 2003
  • Purpose: To report the clinical result of the intraarticular calcaneus fracture after open reduction and internal fixation with plate by lateral approach. Materials and Methods: Thirty-six calcaneal fractures of 33 patients(29 men and 4 women) were treated by open reduction and internal fixation using an lateral approach from March, 1997 to May, 2002 and were followed more than one year. The autogenous iliac bone graft was done in 2 cases but the others didn't. Radiographically B?hler angle and Gissane angle on simple lateral radiograph were measured and in the 15 cases, the step-off(gap) of posterior facet joint on post-operative CT images were followed. The Salama method was used for evaluation of clinical results. Results: According to Sanders classification, 19 cases of the 36 cases were classified as type II. Type III fracture were found in 12 cases and type IV in 5 cases. The following results were obtained: twenty-two cases(61.1%) out of 36 cases were estimated as good or excellent. The good results or more were obtained in 15 cases(78.9%) in type II and 7 cases(58.3%) in type ill, but no case in type IV. B?hler angles were improved from preoperative average 1.6?to postoperative average 23.4?, Gissane angle was improved from preoperative 107.2?to postoperative 122.8?, respectively. Among 36 cases, Computed tomography was carried out in 15 cases. The postoperative step-off (gap) of posterior facet joint on computed tomography was filled with cancellous bone. Satifactory results was obtained in 7 cases with 2mm gap or less and in 6 cases of 2-5mm. There were no satifactory results in 2 cases with 5mm gap or more. Conclusion: Open reduction and internal fixation for intra-articular fracture of calcaneus was thought to be a good treatment modality. It is thought that the lateral approach is one of the good one for surgical treatment, and that accurate reduction of the posterior facet, acceptable recovery of B?hler angle are more important to obtain best results.

  • PDF