• Title/Summary/Keyword: gap distance

Search Result 587, Processing Time 0.027 seconds

Modified T-Plate Interpositional Arthroplasty for Temporomandibular Joint Ankylosis: A New and Versatile Option

  • Ahmad, Imran;Mir, Mohd Altaf;Bariar, Lalit Mohan
    • Archives of Plastic Surgery
    • /
    • 제42권6호
    • /
    • pp.716-720
    • /
    • 2015
  • Background This study has been conducted with the aim of evaluating modified T-plate interpositional arthroplasty. Methods A prospective comparative study in patients admitted with temporomandibular joint ankylosis. Ankylotic temporomandibular joint arthroplasty included condylectomy gap arthroplasty in 7, temporalis muscle flap interpositional arthroplasty in 8, and modified T-plate interpositional arthroplasty in 13 cases. The patients were followed for three years. Collected data were tabulated and subjected to Fisher's exact test, chi-square test and probability estimation. Results A significant increase in interincisal distance of 32 mm was seen in 12 (92.31%) patients in the T-plate interposition group, in 2 (25%) cases of the temporalis muscle flap interposition group, and in 1 case (14.28%) of the condylectomy group at 12, 24, and 36 months. Re-ankylosis was observed in 1 case (9.69%) of the T-plate interposition group, while as it was observed in 4 (50%) cases in the temporalis muscle flap interposition group and 4 (57.14%) cases in the condylectomy group, and these differences were statistically significant. Conclusions Our clinical experience with the use of the T-plate over the past 5 years has been encouraging, and our physiotherapy technique is quite simple. Even illiterate parents can assess it easily. Hence, we recommend this easy technique that does not damage the temporalis muscle for the management of temporomandibular joint ankylosis.

소형 SQUID, 직접 되먹임 방식 전자회로, 고온초전도 SQUID 주사현미경의 개량 (Development of Small-sized SQUID and Direct-coupled Electronics for High-$T_c$ Scanning SQUID Microscope)

  • 백범;이승민;윤주환;김정구
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2001
  • The spatial resolution of $high-T_{c}$ scanning SQUID microscope is limited by the washer size of SQUID and the gap distance between SQUID sensor and the sample. In this work, we tried to improve the spatial resolution of scanning SQUID microscope by reducing the size of SQUID sensor fabricated with $YBa_2$$Cu_3$$O_{7}$ thin film. Outer dimensions of the SQUiDs we tested are 24 $\mu\textrm{m}$ $\times$ $ 28\mu\textrm{m}$, $12 \mu\textrm{m}$ $\times$ $16\mu\textrm{m}$, $12\mu\textrm{m}$ x $12\mu\textrm{m}$, $10 \mu\textrm{m}$ $\times$ $10 \mu\textrm{m}$ each. To operate them in the flux-locked loop scheme, we used a direct-coupled electronics instead of using conventional electronics involving a modulation scheme. Since the direct-coupled feedback scheme does not require modulation current adjustment that poses as a practical difficulty in the SQUID operation in modulation-scheme, the direct feedback operation is rather simpler than the conventional modulation method. The resulting noise features were dominated by the noise of preamp in FLL electronics except that of the largest SQUID. The noise levels of SQUIDs are expected below 1$\times$$10^{-5}$ $\Phi_{0}$H $z^{1}$2/ (at 300 Hz), that is a typical noise level for SQUID made of $YBa_2$C $u_3$$O_{7}$ thin film. The data acquisition and motion-controlling parts were also improved, resulting in faster data acquisition rate and less vibration of the system.m.

  • PDF

자동주차조사 시스템 개발 및 활용에 관한 연구 (A Study on Development and Utilization of Automatic Parking Survey System)

  • 이영우;권혁준
    • 대한교통학회지
    • /
    • 제32권5호
    • /
    • pp.452-461
    • /
    • 2014
  • 기존 주차조사는 광범위한 조사지역을 대상으로 조사원이 직접 주차차량의 번호판을 확인하는 방식으로 기동성의 저하, 조사와 입력의 이원화로 인한 입력오류, 많은 조사시간과 비용이 소요되는 단점을 가지고 있었다. 따라서 본 연구에서는 기존 조사원에 의한 주차조사의 단점을 극복하기 위해 최근 상용화된 고성능 영상분석장비, 위성측량장비, 적외선 조명 등을 이용하여 자동주차조사를 위한 방법에 관한 연구를 수행하였으며 본 연구결과 개발된 자동주차조사 방법을 이용하여 조사된 데이터를 수정, 저장, 분석 및 출력이 가능한 주차분석 소프트웨어를 개발하였다. 장비를 이용한 자동주차조사 시 조사차량의 주행속도, 영상분석장비의 촬영각도, 주차차량 상호간 차간간격, 조사차량과 주차차량의 이격거리 등에 의해 조사의 정밀도가 영향을 받는 것으로 나타나 장비를 이용한 자동주차조사의 정확도를 향상시키기 위해 실험을 통해 각 요소별 최적조합을 도출하였다. 또한 기존 주차조사 데이터가 체계적으로 저장, 관리되지 못하고 있는 문제점을 극복하고 주자정책 수립을 지원하기 위한 주차분석을 지원하기 위한 주차분석 소프트웨어를 개발하였다.

Very High Frequency Multi Hollow Cathode PECVD 장치의 수치모델링 (Numerical Modeling of Very High Frequency Multi Hollow Cathode PECVD)

  • 주정훈
    • 한국진공학회지
    • /
    • 제19권5호
    • /
    • pp.331-340
    • /
    • 2010
  • 초고주파 다중 중공 음극 방전을 이용한 플라즈마 화학 기상 증착 장치를 3차원 수치 모델링하였다. 기본적인 방전 특성을 파악하기 위하여 알곤 플라즈마를 40 MHz, 100 V, 133.3 Pa (1 Torr)의 조건에 대해서 계산하였다. 6 mm 직경의 홀을 20 mm 간격으로 배열하였고 전극 간격은 10 mm를 가정하였다. 피크 플라즈마 밀도는 홀의 하부 중앙에서 $5{\times}10^{11}#/cm^3$ 였으며 전자 온도는 접지 상태로 가정한 기판과 챔버 벽면 주위에서 가장 높았다. 준안정 상태에 의한 2단 이온화 속도는 전자 충돌에 의한 직접 이온화보다 10배 가량 높았다. 수소에 대한 계산에서는 이온화 이외의 다양한 에너지 소모 경로가 있어서 방전의 국재화가 잘 이루어지지 않았다.

Meta Frontier를 이용한 국내 IT서비스기업의 효율성 분석 및 Tobit 모형을 이용한 효율성 결정요인 분석에 대한 연구 (A Study on the Efficiency Analysis of IT Service Companies Using Meta Frontier and the Determinants of Efficiency Using Tobit Model)

  • 신민수;박지용
    • 한국IT서비스학회지
    • /
    • 제16권4호
    • /
    • pp.15-31
    • /
    • 2017
  • This study analyzes 45 Korea IT service companies from 2012 to 2016 using DEA analysis. Large enterprises, medium enterprises and small and medium enterprises (SMEs). CCR model and BCC model were used for efficiency analysis. Among the various analytical objects, the decision objects which yield the maximum output with minimum input are compared with other analysis objects. The relative inefficiency was measured through this, and Technical Efficiency (TE), Pure Technology Efficiency (PTE), Scale Efficiency (SE), scale profit, reference frequency were analyzed. Also, we analyzed the Technology Gap Ratio (TGR), which is the distance between production function and Meta-Frontier for each firm, using Meta-Frontier analysis. Finally, the Tobit model is used to analyze the sources of efficiency and inefficiency. The inputs are assets, capital, and employees, and the output factor is sales. The analysis shows that large firms are achieving technological achievements more efficiently than small and medium enterprises. As a result, medium-sized enterprises and SMEs can improve efficiency overall through efficient operation of workforce and appropriate combination of inputs such as assets and capital. Also, as a result of the influence factor analysis, it was found that the ratio of the managed asset ratio and the management cost ratio were significant factors influencing the efficiency of the IT service companies. This study suggests the efficiency analysis using DEA for many Korea IT service companies. Inefficient parts of each company are classified according to size and technology. Also, we identify the most efficient companies and analyze the causes of those companies whose profits are lower than their size.

가스터빈 연소실 냉각을 위한 충돌제트/유출냉각기법에서 사각핀 설치에 따른 열/물질전달 특성 (Heat/Mass Transfer Characteristics in Impingement/Effusion Cooling System with Rectangular Fins for Combustor Liner Cooling)

  • 홍성국;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.289-296
    • /
    • 2004
  • The present study has been performed to investigate the influences of rectangular fins on heat transfer in an impingement/effusion cooling system with crossflow. To simulate the impingement/effusion cooling system with initial crossflow, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter. The crossflow passes between the plates, and various rectangular fins are installed on the plates. Reynolds number based on the hole diameter is fixed to 10,000 and the flow rate of crossflow is changed from 0.5 to 1.5 times of that of the impinging jet. A naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. Also to analyze the flow characteristics, a numerical calculation is performed. When rectangular fins are installed, the flow and heat transfer pattern is changed greatly from case without fins. In the injection hole region, the jet impinges on effusion plate without deflection and wall jet spreads symmetrically. In the effusion region, the crossflow accelerates due to the decrease of cross-sectional area in the channel. Local heat/mass transfer coefficients are enhanced significantly compared to case without fins. As the blowing ratio increases, the effect of fins against the crossflow becomes more significant and then the higher average heat/mass transfer coefficients are obtained than the case without fins.

  • PDF

장축 실린더의 열변형 최소화를 위한 차열관 효과 해석 및 실험 연구 (An Analytical and Experimental Study on the Thermal Shroud Effect to Minimize Thermal Deformation of a High L/D Ratio Cylinder)

  • 안상태
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.54-63
    • /
    • 2007
  • A barrel is a high length-to-diameter ratio cylinder that is influenced by environmental factors such as sunlight, precipitation, wind and clouds. Cross-barrel temperature differences caused by uneven heating or cooling lead to thermal deformation that degrades accuracy. Therefore, a barrel is covered by thermal shrouds to minimize the type of thermal deformation, "fall-of-shot". In this paper, an analytical and experimental study is presented to design the thermal shrouds for a gun barrel and to evaluate the thermal shroud effect. First, an analytical study on the thermal shroud effect to minimize thermal deformation of a gun barrel by sunlight and wind is performed. The coupled analysis of thermal fluid dynamics of the air flow between a barrel and thermal shrouds and thermal stresses of a barrel Is performed to clarify both the thermal shroud effect and the drift in gun muzzle orientation by thermal deformation. Second, experiments are carried out to test and evaluate the thermal shroud effect on the performance of a gun barrel. The drift in gun muzzle orientation against the solar radiation is confirmed by the experiments, and the results well agree with the analytical estimation. Third, three principal design factors that are presumed to have an effect on the performance of the thermal shrouds are also analyzed; sorts of shroud materials, wall-thickness of thermal shrouds, and distance of the gap between a barrel and thermal shrouds.

박막 요소를 이용한 스피커 그릴 일체형 맵 포켓의 사출 성형 해석 (Injection Molding Analysis of Map Pocket with a Speaker Grill Using Shell Element)

  • 김홍석;조명상;손중식;서태수;김태웅
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1294-1301
    • /
    • 2001
  • In order to reduce the time and cost for assembly, automobile speaker grills have been injection molded with door trims or map pockets in one piece recently. However, several defects such as short shots or air traps can easily occur due to the decreased fluidity of the melting polymer according to the excessive heat transfer to the mold. Therefore, it is necessary to optimize the resin feed system and predict possible defects by CAE analysis. However it is not possible to obtain exact analysis results for the speaker grill by using general shell elements since the heat transfer in the thickness direction which is the dominant factor of the filling stage can not be considered. Therefore, there have been several efforts to simulate the injection molding nature of the speaker grill by using shell elements with an effective thickness which is smaller than the actual thickness of the part. Two empirical values have been recommended for the effective thickness in real practice. One is 50∼70% of the thickness of the speaker grill and another is the gap distance between the adjacent holes. In this paper, CAE analyses of a map pocket with a speaker grill were conducted using shell elements with both of these recommended effective thicknesses, and the predicted flow fronts were compared with the findings from injection molding experiments. The commercial code MOLDFLOW was used for injection molding analysis and an 850 ton injection molding machine was used for experiments.

응력 및 변위를 최소화하기 위한 단엽식 고분자 판막의 유한 요소 해석 (Finite Element Analysis of the Monoleaflet Polymer to Minimize Stress and Displacement)

  • 한근조;안성찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.85-92
    • /
    • 1996
  • 병변이 있는 판막을 대체하기 위하여 사용되는 인공판막으로는 기계식 판막, 고분자 판막 등이 있는데 고분자 판막이 기계식보다 항혈전성이 우수하므로 폴리우레탄을 이용하여 많이 연구되고 있다. 고분자 판막에는 단엽식, 삼엽식, 젤리피쉬식 등으로 제작되어 연구되고 있는데 이중 단엽식 판막은 제작이 가장 간편하고 심실내 씻김현상이 실제와 유사하며 혈류의 소용돌이 현상을 감소시킨다고 보고되고 있다. 혈압 강하를 감소시키기 위하여 고분자 판막의 두께를 얇게 할때 판막이 프레임 위 정상접촉 위치로 부터 탈구현상이 발생한다. 이것을 방지하기 위하여 2개의 지지대를 설치하여 판막의 수직변위를 최소로 하는 지지대 최적위치를 구하고, 그때 판막 끝의 수평 변위 및 판막에서의 응력분포상태를 구한 결과 최적위치는 지지대에 의해 나눠지는 3영역의 폭이 각각 6.2mm, 4.7mm, 5.1mm 일때 이고, 그때 최대 처짐이 0.19mm, 수평 최대변위가 0.047mm 이고 최대 주응력이나 등가응력의 최대치는 판막이 지지대가 접착되는 부위와 비접착 부위의 불연속점에서 발생하여 이 값들은 판막 각 영역의 폭이 커지면 증가함을 알았다.

  • PDF

Realization of High Impedance Surface Characteristics Using a Periodically Transformed Artificial Magnetic Conductor Structure and Reduction Technique of Specific Absorption Rate

  • Lee, Seungwoo;Rhee, Seung-Yeop;Kim, Pan-Yeol;Kim, Nam
    • Journal of electromagnetic engineering and science
    • /
    • 제13권2호
    • /
    • pp.113-119
    • /
    • 2013
  • We developed a transformed, symmetrical, mushroom-like surface without via holes in cells focused on a 2.4-GHz WLAN band. Each slot in the novel type structure plays a key role in modeling at the desired frequencies. The designed artificial magnetic conductor (AMC) has several advantages, including a small size, a wider bandwidth, a short reflecting distance to the antenna, and easy fabrication because there are no via holes. Overall dimensions of the AMC cell are 21 mm $(Width){\times}21mm$ $(Height){\times}2.6mm$ (Thickness), and the bandwidth is about three times wider (11.7%) compared to that of a conventional AMC (4.0%). For evaluating the performance of the proposed structure, a reflector, which periodically consists of the designed AMC cells, was developed. The antenna with the investigated AMC reflector not only works within a quarter of the wavelength because of the extremely high wave impedance generated by the AMC cells on the surface of the structure but also reduces the specific absorption rate (SAR). Electromagnetic field (EMF) exposure to a human phantom was analyzed by applying the designed reflector to the 2.4-GHz dipole antenna in a tablet PC. The calculated peak SAR averaged over 1 g was 0.125 W/kg when the input power was 1 W and the antenna was located at 20 cm from the human phantom. However, the SAR value was only 0.002 W/kg (i.e., 98.4% blocked) when the designed reflector was inserted in front of the antenna.