• 제목/요약/키워드: gamma-ray spectrum

검색결과 159건 처리시간 0.024초

조직 등가 섬광체를 이용한 계수형 선량계의 개발과 특성 평가 (Development and Characterization of a Dosimeter Using Tissue-Equivalent Scintillator by Photon-Counting Method)

  • 천종규;김성환;김홍주
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2014
  • A dosimeter using tissue-equivalent scintillator by photon-counting method was developed and evaluated in its performance. The dosimeter is portable and can be operated by low power from lap-top computer. A data-acquisition software of the dosimeter system was developed by Labwindows/CVI based on Windows. The energy to channel ratio for energy calibration was 0.839 keV/ch. obtained from pulse height spectrum of $^{137}Cs$ and $^{60}Co$ gamma-ray. Using the dosimeter system, the absorbed dose of environmental radiation in Gyungju was 0.18 ${\mu}Sv/h$.

Assessment of Nuclear Characteristics of NAA #1 Irradiation Hole in HANARO Research Reactor for Application of the $K_0$-NAA Methodology

  • Moon, Jong-Hwa;Kim, Sun-Ha;Chung, Yong-Sam;Dung, Ho-Mahn
    • Nuclear Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.566-573
    • /
    • 2002
  • Neutron activation analysis based on $textsc{k}$$_{o}$-standardization method# ($textsc{k}$o-NAA) is Com as one of the most remarkable progresses of the NAA with advantages of experimental simplicity, high accuracy, excellent flexibility with respect to irradiation and counting conditions, and suitability for computerization. This study was carried out to determine the reactor neutron spectrum parameters, i.e. $\alpha$ and f as the main factors of irradiation quality at NAA #1 irradiation hole on HANARO research reactor, to evaluate peak detection efficiency of the gamma-ray spectrometer for the use in the $textsc{k}$$_{o}$ experiments and to compare the measured concentration results with the certified values of some SRMs applying the experimentally determined to-parameters.ers.

지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가 (MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil)

  • 이준호;김봉기;이동명;변종인
    • 방사성폐기물학회지
    • /
    • 제17권3호
    • /
    • pp.321-328
    • /
    • 2019
  • 본 연구에서는 원자력 사고 또는 방사선 비상 시 지표면에 침적될 수 있는 감마선방출 핵종의 방사능을 신속하게 평가하기 위해 이용될 수 있는 NaI(Tl), $LaBr_3$(Ce) 및 $CeBr_3$ 섬광검출기의 성능을 비교 평가하였다. 검출성능은 최소검출가능방사능(MDA, Minimum Detectable Activity)을 통해 평가하였으며, 각 검출기의 지표면 침적 감마선방출 핵종에 대한 검출효율은 수학적 모델링과 점선원을 이용하여 반실험적으로 산출하였다. MDA 평가를 위한 백그라운드 감마선에너지스펙트럼은 비교적 넓고 평탄한 초지에서 측정되었으며, 원자력 사고 시 방출될 수 있는 주요 핵종에 대한 각 검출기의 MDA를 산출하였다. 그 결과 일반 환경방사능 준위에서 지표면 침적 감마핵종에 대한 각 검출기의 MDA 크기는 대체로"NaI(Tl)> $LaBr_3$(Ce)> $CeBr_3$"로 평가되었으며, 백그라운드 준위가 유사한 에너지 영역에서는 분해능이 가장 우수한 $LaBr_3$(Ce)에서 최소 값을 보였다. 이는 관심 핵종의 감마선에너지 영역에 대한 각 검출기의 자체 및 측정 환경 백그라운드, 측정 효율, 그리고 에너지 분해능 특성을 바탕으로 비교 분석되었다.

환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정 (Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology)

  • 강수만;임인철;이재승;장은성;이미현;권경태;김창태
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression 장치는 Compton 산란 반응을 이용하여, 스펙트럼의 Compton continuum 부분을 억제함으로써 Compton continuum 영역 내에서의 감마선 피크들의 분석을 보다 명확하게 할 수 있게 해주는 장치이다. 표층토양 시료에서 검출된 인공 방사능인 $^{137}Cs$과 자연 방사능인 $^{40}K$핵종의 방사능 농도 값들에 대한 방사능 계수치가 백그라운드를 상회하는 측정값이 발생되거나, 불필요한 방해피크나 비해석 대상 피크에 대하여 검출된 표준선원의 방사능 농도 값들의 실측치에 대한 background를 비억제 스펙트럼(Compton Unsuppression)과 억제 스펙트럼(Compton suppression)을 적용시켜 측정 에너지에 대한 교정을 알고자 점선원인 $^{137}Cs$을 거리별에 따라 측정하여, 몬테칼로 시뮬레이션과 비교 분석함으로서 효율적인 검출 능력을 얻고자 함이며, Compton 억제 인자를 보면 거리가 멀어짐에 따라 CSF 값이 클수록 더 많은 Compton suppression가 이루어졌음을 알 수 있고, $^{137}Cs$을 이용한 컴프턴 비억제 모드와 억제모드로 측정된 스펙트럼에서 컴프턴 연속에 의한 백그라운드가 감소함을 알 수 있었다.

청색 Diode 개발을 위한 ZnSe 박막성장과 특성에 관한 연구 (Growth and Characterization of ZnSe Thin Film for Blue Diode)

  • 박창선;홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.533-538
    • /
    • 2001
  • The ZnSe sample grown by chemical bath deposition (CBD) method were annealed in Ar gas at 450$^{\circ}C$ Using extrapolation method of X-ray diffraction pattern, it was found to have zinc blend structure whose lattice parameter a$\_$o/ was 5.6687 ${\AA}$. From Hall effect, the mobility was likely to be decreased by impurity scattering at temperature range from 10 K to 150 K and by lattice scattering at temperature range from 150 K to 29 3K. The band gap given by the transmission edge changed from 2.7005 eV at 293 K to 2.8739 eV at 10 K. Comparing photocurrent peak position with transmission edge, we could find that photocurrent peaks due to excition electrons from valence band, $\Gamma$$\_$8/ and $\Gamma$$\_$7/ to conduction band $\Gamma$$\_$6/ were observed at photocurrent spectrum. From the photocurrent spectra by illumination of polarized light on the ZnSe thin film, we have found that values of spin orbit coupling splitting Δso is 0.0981 eV. From the PL spectra at 10 K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be 0.0612 eV and the dissipation energy of the donor -bound exciton and acceptor-bound exciton to be 0.0172 eV, 0.0310 eV, respectively.

  • PDF

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

고감도 보급형 핵종 분석 모듈 개발 (Development of High-Sensitivity and Entry-Level Nuclide Analysis Module)

  • 오승진;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.515-519
    • /
    • 2022
  • 본 논문에서는 고감도 보급형 핵종 분석 모듈 개발을 제안한다. 제안하는 측정센서 모듈은 핵종 분석 분해능을 위한 전자부 구동회로, 핵종 분석 기능이 적용된 시제품 제작, 시제품에 적용되는 GUI 개발 등으로 구성된다. 핵종 분석 분해능을 위한 전자부 구동회로는 전자부 구동 회로 블록도에 의한 핵종 분석 분해능 과정, 방사선 측정에 사용되는 MCU 회로 설계, Spectrum 취득용 PC 프로그램 설계 등으로 나뉘어진다. 핵종 분석 기능이 적용된 시제품 제작은 128×128 픽셀의 OLED display, 조작을 위한 3개의 버튼, Li-ion 배터리, 배터리 충전을 위한 USB-C Type 포트의 구성을 추가하여 제작한다. 시제품에 적용되는 GUI 개발부는 현재시간, 측정 경과 시간, 토탈 카운트, 핵종 Spectrum 등의 화면구성으로 개발한다. 제안된 측정센서 모듈의 성능을 평가하기 위하여 공인기관 전문가 입회시험을 시행한 결과, 핵종 분석 장치에 Cs-137 표준선원을 이용하여 취득한 Spectrum(FWHM@662keV)으로 분해능 공식을 적용하여 계산한 결과가 17.77%의 분해능을 가짐이 확인되었다. 따라서, 제안된 본 논문에서 제안한 핵종 분석 분해능 방법이 기존의 상용의 핵종 분석 모듈보다 저렴하면서도 향상된 성능이 산출됨이 확인되었다.

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.