• Title/Summary/Keyword: gamma scanning

Search Result 233, Processing Time 0.028 seconds

A Study on the Gamma Scanning Test Used for Nondestructive Test Radiation Shielding Material (방사선 차폐체의 감마스케닝검사법에 대한 고찰)

  • Seo, Kyung-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.4
    • /
    • pp.561-567
    • /
    • 1996
  • As nuclear industry in Korea is being expended, the number of user for radioisotope and radiation generators has being remarkably increased. As a result, radiation shielding problem for radiation safety has rasied as a question of great interest nowaday. In this report, gamma scanning test (GST), one of the nondestructive test methods of radiation shielding material was introduced and the review of the test method and its application were described. In addition for accurate evaluation of the test result, necessary basic equipments for the test and for improvement of the equipment were suggested. If the effective test method described above were widely and properly applied by GST related companies, the technology would be used effectively, as one of the safe nondestructive test for radiation shielding material in future.

  • PDF

Determination of Lattice Parameters and Observation of Lattice Misfits on Rene 80 Cast Blades (Rene 80 주조블레이드에서 격자상수의 결정 및 격자어긋남의 관찰)

  • An, Seong-Uk
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.515-520
    • /
    • 1993
  • By the real use of Rene 80 cast blades at high temperature ${\gamma}^{\prime}$ precipitates in the matrix(${\gamma}$) mainly due to the operating temperature. These precipitates play main role for strenthening of the blades. Generally known that dislocation density increases due to ${\gamma}-{\gamma}^{\prime}$ mismatch by the generation and growth of the precipitates, because the lattice parameter of ${\gamma}^{\prime}$ is higher than that of ${\gamma}$. These lattice parameters of ${\gamma}$ and ${\gamma}^{\prime}$ are determined through the CBED(Convergent Beam Electron Diffraction) method by STEM(Scanning Transmission Electron Microscope) in this work. And also studied, whether and how much the dislocation density increases by the generation and growth of the precipitates.

  • PDF

Preparation of cross-linked silk fibroin film by γ-irradiation and their application as supports for human cell culture

  • Park, Hyean-Yeol;Kim, Yoon-Seob;Choi, Seong-Ho
    • Analytical Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • This study described about preparation of the cross-linked silk fibroin (SF) film by ${\gamma}$-irradiation of the casted SF film, which is fabricated from aqueous solution regenerated via fibers of cocoons and their application as supports for human cell culture. The properties of cross-linked SF film were evaluated by FT-IR spectroscopy, contact angle, solubility to water, thermal analysis, surface area analyzer, and morphology via scanning electron microscopy (SEM). The cross-linked SF films were not dissolved in water and exhibited the rough surface morphology, large surface area, and good thermal properties. The human fibroblast cell (CCD-986sk) and embryo kidney-ft cell were well growed on the surface of cross-linked SF film supports prepared by ${\gamma}$-irradiation. The cross-linked SF film prepared by ${\gamma}$-irradiation can be used as biomaterials for human cell culture.

Image Reconstruction Techniques for Radioactive Waste Assay by Tomographic Gamma Scanning Method

  • Zhang Quanhu;Kim Ki-Hong;Hong Kwon-Pyo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.126-140
    • /
    • 2005
  • The tomographic gamma scanner (TGS) method, a further of extension of segmented gamma scanner (SGS), is most accurate and precise for assaying heterogeneous drummed nuclear radioactive waste; it is widely used in nuclear power plants and radioactive waste storages and disposal sites. The transmission and emission images are reconstructed by image reconstruction techniques. In the paper, the principle of TGS is introduced; image reconstruction techniques are discussed as well; finally, it is demonstrated that TGS method performance.

  • PDF

Structural Changes of Polyvinylidene fluoride with $^{60}Co$ $\gamma-ray$ Irradiation (Polyvinylidene fluoride의 $^{60}Co$감마선 조사에 의한 구조 변화)

  • Lee Chung;Kim Ki-Yup;Ryu Boo-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.26-31
    • /
    • 2004
  • The radiation-induced changes taking place in poly(vinylidene fluoride) (PVDF) exposed to $^{60}Co$ $\gamma-ray$ irradiation were investigated in correlation with the applied doses. Samples were irradiated in air at room temperature by $^{60}Co$ $\gamma-ray$ to doses in the range of 200 to 1000kGy. Various properties of the irradiated PVDF were studied using FTIR, differential scanning calorimetry (DSC), gel fraction and elongation. $^{60}Co\gamma-ray$ irradiation was found to induce changes in chemical, thermal, mechanical and structural properties of PVDF and such changes vary depending on the radiation dose.

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.

Synthesis and Characterization of Biocompatible Block Copoly (L-Lactde-$\gamma$-Benzyl-L-Glutamate) (생체적합성 공중합체의 합성과 물성에 관한 연구 -Block Copoly (L-Lactde-$\gamma$-Benzyl-L-Glutamate)-)

  • Sung, Yong-Kiel;Kim, Hoon;Song, Dae-Kyung;Kim, Young-Soon;Paek, U-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.215-224
    • /
    • 1988
  • Block copoly(L-lactide-${\gamma}$-benzyl-L-glutamate)was synthesized from L-lactide by cationic ring opening polymerization and ${\gamma}$-benzyl-L-glutamate N-carboxy anhydride by introducing amino group terminated poly(L-lactide). L-lactide was polymerized in the presence of stannous octate at $110^{\circ}C$ and ${\gamma}$-benzyl- L-glutamate was polymerized in the presence of NaH at room temperature. The synthesized monomers and copolymers were identified by IR and NMR. The Itermal properties of the copolymers were characterized by differential scanning calorimetry and thermogravimetry. The thermal stability and melting temperature(Tm) of the block copolymers were measured and discussed. The activation energies of thermal decomposition for the block copoly(L-lactide-${\gamma}$ benzyl-L-glutamate) were evaluated from the thermogravimetric data by Freeman and Carroll method.

  • PDF

Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline (단열배관의 온라인 두께측정시스템 개발)

  • Jang, Ji-Hun;Kim, Byeong-Ju;Jo, Gyeong-Sik;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.32
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.