GAGG 섬광체 물질을 적용한 감마카메라 영상의 유용성 평가: 몬테카를로 시뮬레이션 연구 (Usefulness of New GAGG Scintillation Detector for Gamma Camera : A Monte Carlo Simulation Study)

  • 김정수;박찬록
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.511-515
    • /
    • 2020
  • 본 연구의 목적은, 새롭게 제안된 Gadolinium Aluminum Gallium Garnet (GAGG) 기반 감마카메라를 Geant 4 Application for Tomographic Emission (GATE) 모사 도구(simulation tool)를 통해 설계하고, National Electrical Manufacturers Association International Electrotechnical Commission에서 제작한 몸통 팬텀 모사를 통해 기존의 사용되고 있는 NaI(Tl) 섬광체 기반 감마카메라 시스템과 99mTc 방사성동위원소를 이용해 900 초 동안 영상을 획득했다. Contrast to noise ratio (CNR) 과 Coefficient of variation (COV) 의 정량분석 방법을 사용해 해당 관심영역에 대해 영상을 평가하였다. CNR 과 COV 결과에 따라, 결과적으로 GAGG 기반 감마 영상의 질이 우수함을 확인하였다.

방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발 (Development of Three-Dimensional Gamma-ray Camera)

  • 이남호;황영관;박순용
    • 한국정보통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.486-492
    • /
    • 2015
  • 방사선 영상장치는 방사능 누출사고의 조기처리 및 확산 피해 최소화에 필수적인 장비이며, 가까운 미래에 빅마켓으로 성장될 원전폐로 분야에서도 중요한 역할을 담당할 것으로 예상된다. 현재까지 개발된 방사선 영상장치는 방사선 오염원의 위치를 방향 정보만으로 탐지하여 가시화하고 있고 방사선원의 거리 측정은 불가능한 실정이다. 본 논문에서는 스테레오 카메라 원리를 적용하여 방사선원의 3차원 위치정보를 추출할 수 있는 새로운 기법의 방사선 3차원 영상장치의 구현에 대해 연구하였다. 한 대의 방사선 센서와 CCD 카메라, 그리고 팬틸의 컴팩트한 구성으로 설계된 방사선 3차원 영상장치(K3-RIS)는 위치변환 제어에 의한 스테레오 방사선 영상 취득과 연속모드 제어 및 고속 스테레오 영상정보처리 기능이 특징이다. 개발한 장치의 기능검증을 위해 감마 방사선원(Cs-137)을 대상으로 실험을 수행한 결과 선원간의 거리와 무관하게 3% 이하의 거리측정 오차를 확인하였다.

핵의학 계측기기 및 감마카메라의 정도관리 연구 (A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.103-112
    • /
    • 2001
  • 목적: 최근 국내의 핵의학 계측기기 및 감마카메라의 정도관리 수행현황을 파악하고, 핵의학 계측기기와 감마 카메라의 정도관리를 수행하고자 하였다. 방 법: 최근 국내의 핵의학 계측기기 및 감마 카메라의 정도관리 수행현황은 총 53개 병원을 대상으로 설문조사방법을 이용하여 수행하였다. 이들의 정도관리 연구는 Capintec의 CRC-15 기종의 dose calibrator와 Tc-99m 35.52 MBq을 사용하여 2분 간격으로 정밀도를 측정하였다. Nucleus사의 기종의 Thyroid Uptake system은 Tc-99m 5.14 MBq을 이용하여 1분 간격으로 10초동안 정밀도를 측정하였다. 지름이 15 cm이고 높이가 각각 12 cm, 30 cm인 원통형 팬텀과 TC-99m을 이용하여 저에너지 고해상도 조준기가 부착된 CeraSPECT$^{TM}$의 예민도를 측정하였다. CeraSPECT$^{TM}$와 일반 평면카메라와의 예민도에 대한 특성비교를 위하여 Varicam (Elscint Ltd, Israel) 감마 카메라로 영상을 얻었다. CeraSPECT$^{TM}$로 획득한 자료로 각 슬라이스에 대한 보정상수를 계산하였다. Elscint 사의 Varicam 감마 카메라의 정도관리를 위해 저에너지 고해상도 조준기를 부착하고 140 keV 중심20% 에너지창, 256$\times$256 또는 512$\times$512 메트릭스 크기를 이용하여 시스템의 평면 예민도, 균일도, 계수율 및 공기중과 산란매질에서의 공간 분해능을 측정하였다. 결 과: 핵의학 계측기기 및 감마 카메라의 정도관리 수행율은 dose calibrator와 well counter의 경우 매우 저조한 수행율을 나타내었으며 그 외 감마 카메라 등은 대체로 양호한 수행율을 나타내었다. dose calibrator의 정밀도 측정은 $\pm$1.4%(<$\pm$5%)의 결과를 얻었고, thyroid uptake system의 정밀도 측정은 chi^2=29.7(>16.92)의 결과를 얻었다. Varicam 감마 카메라의 경우 슬라이스들간에 전반적으로 균일한 민감도를 보여주었으나 CeraSPECT$^{TM}$ 의 경우는 위쪽과 아래쪽 부분의 슬라이스들은 민감도가 두드러지게 떨어져 있었고 팬텀의 중심부분 슬라이스들은 민감도가 매우 높은 것으로 나타났다. 계산한 보정 상수를 이용하여 CeraSPECT$^{TM}$로 얻은 환자 자료를 보정하였을 때 보정전에 비하여 전반적으로 균일한 영상을 얻을 수 있었다. 감마 카메라의 시스템 평면 예민도 측정 결과는 4.39 CPM/MBq 이었으며, 시스템 균일도는 첫 번째 검출기와 두번째 검출기가 각각 2.14%, 3.79%로 나타났다. 시스템 계수율 측정의 경우 입력 계수율 R_20%가 각각 102,407 counts/sec (head 1), 113,427 counts/sec (head 2)일 때 20% 계수율 손실이 발생했을 때의 측정된 계수율 C_20%는 각각 81,926 counts/sec (head 1), 90,741 counts/sec (head 2) 이었다. 공기 중에서의 시스템의 공간 분해능은 FWHM이 8.16 m, FWTM이 14.85 mm이었고, 산란매질에서는 시스템의 공간 분해능은 FWHM이 8.87 mm, FWTM이 18.87 mm이었다. 결 론: 정확하고 신뢰도 높은 검사를 위해 정도관리는 필수이며, 이에 대한 명확한 인식과 실질적인 수행이 반드시 뒤따라야 할 것으로 사료되었다

  • PDF

From Brown Dwarfs to Gamma Ray Bursts at High Redshift: Overview of Current CEOU Activities

  • 임명신
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.55.2-55.2
    • /
    • 2011
  • We present the current research activities of the Center for the Exploration of the Origin of the Universe, a center established at Seoul National University with the Creative Research Initiative program. Our activities focus on observational studies of distant objects such as gamma-ray bursts, quasars, and proto-cluster of galaxies, but we also carry out other observational and theoretical studies in related topics. We also developed a new instrument, Camera for Quasars at Early Universe (CQUEAN) in collaboration with Kyunghee University group, and have secured observing facilities such as UKIRT and McDonald 2.1m observatory. Our research highlights include results such as the discovery of high redshift quasars and gamma ray bursts, the discovery of tidal disruption event at z=0.38 and peculiar gamma ray burst events, analysis of proto-clusters of galaxies, the discovery of brown dwarfs, and development of CQUEAN and its usage at the McDonald observatory.

  • PDF

고선량율 감마선 환경하에서의 카메라 관측성능 (Monitoring Performance of Camera under the High Dose-rate Gamma Ray Environment)

  • 조재완;정경민
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1172-1178
    • /
    • 2012
  • In this paper, the gamma ray irradiation test results of the CCD cameras are described. From the low dose-rate (2.11 Gy/h) to the high dose-rate (150 Gy/h) level, which is the same level when the hydrogen explosion was occurred in the 1~3 reactor unit of the Fukushima nuclear power plant, the monitoring performance of the cameras owing to the speckles are evaluated. The numbers of speckles, generated by gamma ray irradiation, in the image of cameras are calculated by image processing technique. And the legibility of the sensor indicator (dosimeter) owing to the numbers of the speckles is presented.

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jong Hwi
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.207-217
    • /
    • 2017
  • For effective patient treatment in proton therapy, it is therefore important to accurately measure the beam range. For measuring beam range, various researchers determine the beam range by measuring the prompt gammas generated during nuclear reactions of protons with materials. However, the accuracy of the beam range determination can be lowered in heterogeneous phantoms, because of the differences with respect to the prompt gamma production depending on the properties of the material. In this research, to improve the beam range determination in a heterogeneous phantom, we derived a formula to correct the prompt-gamma distribution using the ratio of the prompt gamma production, stopping power, and density obtained for each material. Then, the prompt-gamma distributions were acquired by a multi-slit prompt-gamma camera on various kinds of heterogeneous phantoms using a Geant4 Monte Carlo simulation, and the deduced formula was applied to the prompt-gamma distributions. For the case involving the phantom having bone-equivalent material in the soft tissue-equivalent material, it was confirmed that compared to the actual range, the determined ranges were relatively accurate both before and after correction. In the case of a phantom having the lung-equivalent material in the soft tissue-equivalent material, although the maximum error before correction was 18.7 mm, the difference was very large. However, when the correction method was applied, the accuracy was significantly improved by a maximum error of 4.1 mm. Moreover, for a phantom that was constructed based on CT data, after applying the calibration method, the beam range could be generally determined within an error of 2.5 mm. Simulation results confirmed the potential to determine the beam range with high accuracy in heterogeneous phantoms by applying the proposed correction method. In future, these methods will be verified by performing experiments using a therapeutic proton beam.

다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발 (Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera)

  • 박종훈;이한림;김성훈;김찬형;신동호;이세병;정종휘
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.37-45
    • /
    • 2016
  • 양성자 치료 시 양성자 빔의 특성을 이용하여 치료 부위에 국부적인 선량을 부여하고 정상조직에 불필요한 선량을 줄이기 위해서는 인체 내 양성자 빔의 비정을 실시간으로 확인하는 것이 중요하다. 이를 위해 본 연구팀은 24개의 섬광검출기 배열 및 24채널의 신호 처리 시스템으로 구성된 즉발감마선 카메라 모듈을 개발하고 있다. 본 연구에서는 다채널의 섬광 검출기 신호를 처리하기 위하여 이중모드 다채널 신호 처리 모듈을 개발하여 그 성능을 평가해보았다. 성능을 평가한 결과 에너지 교정 모드를 통해 다채널의 섬광검출기에 대하여 동시에 에너지 교정이 가능함을 확인하였고, 이를 통하여 정확하게 3 MeV에 해당하는 측정 하한 값을 결정할 수 있었다. 고속 데이터 획득 모드를 통해 45 MeV 양성자 빔에서 발생한 즉발감마선 분포를 측정한 결과 $3{\times}10^9$개의 양성자 빔에서도 양성자 선량 분포와 유사한 결과를 얻을 수 있었고, 빔 비정을 평가한 결과 $17.13{\pm}0.76mm$로 EBT film을 통하여 측정한 비정인 16.15 mm와 굉장히 밀접한 관련이 있음을 확인하였다.

감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발 (The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system)

  • 송근영;황영관;이남호;육영호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.942-943
    • /
    • 2016
  • 스테레오 감마선 탐지장치는 감마선을 신호를 측정하여 위치값을 통한 2차원의 감마선 영상을 생성 한후, 가시광영상과 중첩하여 실제 공간상의 감마선 분포를 나타낸다. 스테레오 감마선 탐지장치는 감마선 탐지센서를 포함하는 탐지부와 감마선 신호를 검출하는 신호측정부 그리고 탐지부의 위치를 제어하기 위한 모션제어부로 구성된다. 본 논문에서는 개별적으로 구성된 각각의 모듈을 효율적으로 운용하기 위한 시스템 운용 알고리즘을 개발하였고, 이를 통해 감마선 조사시험장에서 감마선에 대한 영상화 및 분포정보 출력을 확인하였다.

  • PDF

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.