• Title/Summary/Keyword: galvanic

Search Result 351, Processing Time 0.027 seconds

Assessment of external corrosion deterioration of large diameter metallic water pipes buried in reclaimed land (간척지대에 매설된 대구경 금속관의 외면 부식손상 평가)

  • Lee, Ho-Min;Choi, Tae-Ho;Kim, Jung-Hyun;Bae, Cheol-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.373-383
    • /
    • 2020
  • The purpose of this study was to evaluate the corrosion damage of large diameter metallic pipes buried in reclaimed land due to the corrosion effect by soil, and to propose a method of installing metal pipes in the reclaimed land. The results are as follow. First, the soil of the reclaimed land was gray clay, the soil specific resistance indicating soil corrosiveness was at least 120 Ω-cm, the pH was weakly acidic(5.04 to 5.60), the redox potential was at least 62 mV, the moisture content was at most 48.8%, and chlorine ions and sulfate ions were up to 4,706.1 mg/kg and 420 mg/kg. Therefore, the overall soil corrosivity score was up to 19, and the external corrosion effect seems to be very large. Second, the condition of straight part of pipes was in good condition, but most of KP joints were affected by corrosion at a severe level. The reason for this seems to be that KP joints accelerated corrosion due to stress and crevice corrosion in addition to galvanic corrosion in the same environment. Third, as a result of evaluating correlations of each item that affects the corrosion on the external part, the lower the soil resistivity and redox potential, the greater the effect on the KP joints corrosion, and the moisture content, chloride ion, and sulfate ion, the higher the value, the greater the effect on the corrosion of KP joints. In addition, among soil corrosion items, the coefficient of determination of soil resistivity with corrosion of KP joints was the highest with 0.6439~0.7672. Fourth, when installing metal pipes or other accessories because the soil of the reclaimed land is highly corrosive, it is necessary to apply a corrosion preventive method to extend the life of pipes and prevent leakage accidents caused by corrosion damage to the joint.

Comparison of Human Sensibility in Driving Simulator and Roller-Coaster Simulator (자동차 시뮬레이터와 롤러코스터 시뮬레이터 주행에 따른 감성 비교)

  • 민병찬;전효정;강인형;성은정;김철중;윤석준
    • Science of Emotion and Sensibility
    • /
    • v.6 no.3
    • /
    • pp.13-20
    • /
    • 2003
  • In an experimental study, we assessed human sensibility in terms of psychophysiological response according to change of speeds (40, 70, 100km/h) in a driving simulator and application of motion fitters (washout filter, non-washout later) in a roller coaster simulator. For the driving and roller coaster simulators, a group of 12 healthy men in their twenties and a group of 8 healthy men in their twenties, respectively, participated. Participants each completed a simulator sickness questionnaire (SSQ), a subjective assessment of sensations of pleasantness, tension, and arousal, and perception of speed. Physiological signals were measured by 1/f fluctuation of EEG (electroencephalogram), ECG (electrocardiogram), and GSR (galvanic skin response). These were measured pre-to-post under the experimental conditions for each simulator. Subjective pleasantness, tension, arousal, and perception of speed and physiological responses indicating a feeling of pleasantness by 1/f fluctuation were higher for the roller coaster simulator than those measured for low speed driving in the driving simulator. The mean frequency of alpha band (8-l3㎐) in EEG increased with exposure to the driving simulator relative to that for the roller coaster simulator. Heart rate variability and GSR were significantly changed between pre- and post- under each condition in the driving and roller coaster simulators. The data suggest that subjective sensibility was elevated according to gain of speed and variety of simulator motion, and physiological responses were activated with increased speed.

  • PDF

The Development and its Application of Diagnostic Technique for Corrosion Defect of U-type Open Rack Vaporizer (개방형 U-type 기화기의 부식손상부 진단기법 개발 및 적용)

  • Jang S. Y.;Lee S. M.;Oh B. T.;Kho Y. T.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.45-50
    • /
    • 2001
  • Open rack vaporizer (ORV) has been used in liquefied natural gas (LNG) receiving terminal in order to vaporize LNG into natural gas (NG) by heat exchange with seawater The U-type ORV which had been operated with seawater for 14 years is one of the important utilities of the gas production and the weld part of tube connected with header_ pipe had experienced many corrosion problems. To elucidate the cause of corrosion at weld part of vaporizer tube, corrosion potentials were compared by parts. This study concerns on the measurement of corrosion pit depth using non-destructive method and the evaluation of stress distribution in an aspect of safety with finite element analysis. In order to confirm the reliability of galvanic corrosion between weld parts and base metal, the measurement of corrosion potential by parts was conducted for 20 minutes in 3.5$\%$(wt.) NaCl solution. Many non-destructive methods were tried to measure the remaining thickness of vaporizer tube at fields. For general corrosion, tangential radiography test was confirmed as an effective method. In case of a fine corrosion pit, the shape of corrosion pit was reproduced using surface replication method. From collected data, stress distributions were quantitatively evaluated with 2-dimensional finite element method and the diagnostic evaluation on internal pressure of the U-type vaporizer could be made.

  • PDF

Evaluation of the corrosion property on the welded zone of seawater pipe by A.C shielded metal arc welding (교류 피복아크 용접에 의한 해수 배관 용접부위의 부식 특성 평가)

  • Jeong, Jae-Hyun;Kim, Yun-Hae;Moon, Kyung-Man;Lee, Myeong-Hoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.877-885
    • /
    • 2013
  • A seawater pipe of the engine room in the ships is being surrounded with severely corrosive environments caused by fast flowing of the seawater, containing aggressive chloride ion and high conductivity etc.. Therefore, the leakage of the seawater from its pipe have been often occurred due to its local corrosion by aggressive chloride ions. Subsequently, its leakage area is usually welded by AC shielded metal arc welding with various electrodes. In this study, when the sea water pipe is welded with several types of electrodes such as E4301, E4311, E4313 and E4316, a difference of the corrosion resistance on the welding metal zones was investigated using an electrochemical method, observing microstructure, measuring polarization behaviors and hardness. The weld metal zone welded with E4313 electrode exhibited the lowest value of hardness compared to other weld metal zones. In addition, its zone indicated also the best corrosion resistance than those of other weld metal zones. Furthermore, all of the weld metal zones revealed a relatively better corrosion resistance than those of the base metal zones. and also showed higher hardness than the base metal zones.

Material Characteristic of POFA Concrete and Its Application to Corrosion Resistance Evaluation (POFA 콘크리트의 재료특성 및 부식 저항성 평가로의 적용)

  • Lee, Chang-Hong;Song, Ha-Won;Ann, Ki-Yong;Ismail, Mohamed Abdel
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.565-572
    • /
    • 2009
  • In this study, corrosion resistance of palm oil fuel ash (POFA) concrete as a blended concrete is evaluated by using electrochemical technique. The POFA is an industrial byproduct obtained from fuel ash after extracting palm oil from palm-tree. In order to obtain basic material characteristics of the POFA concrete, tests on compressive strength, slump, weight loss, bleeding and expansion ratio were carried out the early-aged POFA concrete. On the other hand, durability characteristics, both chloride penetration and carbonation depth test, were also conducted. Finally, corrosion resistance were evaluated by applying electro-chemical artificial crack healing technique, and the tests on the impressed voltage characteristic, galvanic current and linear polarization resistance. From the experimental results, it was found that long-term strength, bleeding, lower slump ratio, expansion ratio, chloride penetration, carbonation and corrosion resistance were improved by using the POFA due to activated pozzolanic reaction. It can be also mentioned that POFA concrete has a potential to be used as a cementitious binder for green-recycling resources.

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

Evaluations on Driver's Sensibility Changes by Sudden Start and Sudden Stop Conditions in Driving Simulator (자동차 시뮬레이터에서의 급출발 및 급제동에 따른 운전자 감성 평가)

  • 전효정;민병찬;성은정;김철중
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.51-57
    • /
    • 2002
  • The purpose of the study was to measure and compare driver's psychophysiological responses in different driving conditions through driving simulator. Twelve male adults(more than 1 year of driving experience) were assigned to four different driving conditions, such as normal speed(70㎞/h), sudden start(0㎞/h→70㎞/h), and sudden stop(70㎞/h→0㎞/h), and their simulator sickness, subjective pleasantness and arousal, EEG, ECG, skin temperature, and GSR were measured. Subjective and physiological evaluations were executed before and after driving in each condition. The results showed that subjective pleasantness and arousal increased in sudden stop and sudden start conditions, relative to stop and normal speed conditions. As the central nervous responses, beta wave increased and alpha wave decreased in sudden stop and sudden start conditions, relative to stop and normal speed conditions. With regard to the autonomic responses, heart rate and GSR increased, while skin temperature decreased in sudden stop and sudden start conditions, which means an activation of sympathetic nervous system. The results suggested that based upon observation of the distinctive psychophysiological changes by driving conditions, it is possible to evaluate the human sensibility in dynamic environment.

  • PDF

A Study on Galvanic Corrosion properties between differential Al Alloys (이종 알루미늄 합금 간 갈바닉 부식 특성에 관한 연구)

  • Kim, Sun-Ho;Lee, Seul-Gi;Park, Jun-Mu;Park, Jae-Hyeok;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.96-96
    • /
    • 2018
  • 금속재료 중 알루미늄(Al)은 일반적으로 많이 사용되는 철강재에 비해 그 비중이 약 $1/3(2.7g/cm^3)$인 경량이고 열전도율이 약 3배($196kcal/^{\circ}C$, $20^{\circ}C$)로 높은 특성 등을 갖고 있다. 또한 대량생산에 의한 경제성을 가지기 때문에 건축 구조재, 전기 및 가전 등 다양한 산업 분야에서 널리 사용되고 있다. 특히, 위와 같은 특성으로 인해 열교환기의 종류에서 응축기(Condenser) 및 증발기(Evaporator)는 알루미늄(Al)을 널리 사용하고 있다. 하지만 단일 응축기 부품에도 이종 알루미늄 소재가 사용됨에 따라 갈바닉 부식이 발생할 수 있다는 단점이 있다. 따라서 본 연구에서는 현재 상용되고 있는 열교환기 중 응축기에서의 이종 알루미늄 재료로 인해 나타나는 갈바닉 부식 특성을 관찰-분석-연구 하였다. 본 연구에 사용된 알루미늄 재료는 현재 응축기 재료 중에서 각각 Tube와 Fin으로 널리 상용되고 있는 Al 1100과 Al 3003을 사용하였다. 표면 모폴로지는 SEM을 통해 관찰하였고 EDS를 통해 조성원소를 분석하였다. 또한 내식성 평가를 위해 5% NaCl 환경에서의 SST(Salt spray test, 염수분무시험) 시험과 3% NaCl 용액 내 자연침지 시험 및 탈기된 3% NaCl 용액 내 전기화학적 동전위 양극 분극 시험을 진행하였으며 더불어 갈바닉 부식 시험에 따른 혼합 전위 측정 및 외관 관찰을 하였다. 각 재료는 실험에 대해 동일한 표면적을 노출시켜 시험하였다. 5% NaCl 환경에서의 염수분무 시험 결과 Fin(Al 3003)의 경우에는 Tube(Al 1100) 보다 빠른 부식거동을 보이며 국부적인 공식부식(Pitting corrosion)이 촉진되었다. Tube(Al 1100)의 경우에는 치밀한 Al2O3 형성과 부식에 따른 Al(OH)3를 생성함에 따라 Fin(Al 3003)에 비해 느린 부식거동을 보였다. 3% NaCl 용액 내 자연 침지 및 전위 측정 결과 초기 전위는 Fin(Al 3003, 약 -0.85V/SCE)이 Tube(Al 1100, 약 -1.05V/SCE)에 비해 더 높은 값을 가지며 약 72시간 이후 Tube(Al 1100) 시편이 더 안정적인 전위 값을 나타냈다. 이는 안정적인 Al(OH)3 피막 형성에 기인한 것으로 사료된다. 탈기된 3% NaCl 용액 내 전기화학적 동전위 양극 분극 시험 결과 Fin(Al 3003) 시편에서 더 귀한 부식 전위 값을 나타냈지만 부식 전류는 더 낮은 값을 나타냈다. 상기 시험 결과를 바탕으로 Fin-Tube 간 장기간 접촉 시에는 갈바닉 부식이 발생할 수 있을 것으로 사료된다. 갈바닉 부식 시험 결과 초기 혼합 전위는 약 -1.05 V/SCE를 나타냈으며 약 288시간 경과 후 약 -0.85 V/SCE 값을 나타냈다. 이는 자연 전위 측정 및 동전위 양극 분극 시험에서의 부식 전위 값에서 알 수 있듯이 더 비한 전위인 Tube(Al 1100) 시편이 Fin(Al 3003) 시편에 대해 희생양극적(Sacrificial anode)인 역할을 한 것을 확인할 수 있었다. 또한 갈바닉 부식 전위 측정 간 외관 관찰에서도 Tube(Al 1100) 시편은 빠르게 흑변 하는 것을 확인할 수 있었으며 Fin(Al 3003) 시편은 침지 300시간 이후에도 초기와 유사한 표면 상태 및 광택을 유지하였다. 이상의 SST 시험, 자연 침지 시험, 전기화학적 양극 분극 시험 및 갈바닉 부식 시험 결과를 바탕으로 단일 부품 내 이종 알루미늄 소재 간 접촉 및 그에 따른 갈바닉 부식 발생을 확인할 수 있었다. 따라서 동종 성분이라고 할지라도 단일 부품 제작 시에는 그 사용 환경에 따라 이종 금속 재료의 사용에 대한 재고가 필요할 것으로 사료된다.

  • PDF

Analysis of Voltaic Cell Described in the Science Textbooks of Secondary Schools (중·고등학교 과학 교과서에 제시된 볼타전지에 대한 문제점 분석)

  • Sin, Dong-Hyeok;Lee, Sang-Gwon;Choe, Byeong-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.363-377
    • /
    • 2002
  • The purpose of this study was to improve the problems of the voltaic cell described in the science textbooks of secondary schools. For this purpose, the contents of science textbooks which are related to the voltaic cell were analyzed and the problems which were not explained clearly by theorems were tried to be explained by experiments, and lastly sug-gestions were made toward the improvements regarding the voltaic cell in the science textbooks. The findings are that there are problems on the ways of ensuring whether the voltaic cell operates properly as a chemical battery, on the explanation of why the hydrogen bubbles form at the zinc electrode, on the cell potential, on the unification of the electrode terminology used, and on the mention of the current. Solutions to the problems except the cell potential were suggested. According to the experiment, the theoretical potential was calculated by considering the potentials of redox reactions at the two electrodes of the cell and by taking into account the characteristics of the electrodes such as the work function, ionization energy, stan-dard reduction potential, and electronegativity.The cell potential of the voltaic cell is explained by several factors. In the improved version of the textbook's introduction section to the voltaic cell, it is necessary to describe the voltaic cell his-torically.For the conceptual section, it should be explained in terms of the Daniel cell.

Fabrication and Catalysis of $SiO_2$-Coated Ag@Au Nanoboxes

  • Lee, Jae-Won;Jang, Du-Jeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.588-588
    • /
    • 2013
  • Nanoscale noble-metals have attracted enormous attention from researchers in various fields of study because of their unusual optical properties as well as novel chemical properties. They have possible uses in diverse applications such as devices, transistors, optoelectronics, information storages, and energy converters. It is well-known that nanoparticles of noble-metals such as silver and gold show strong absorption bands in the visible region due to their surface-plasmon oscillation modes of conductive electrons. Silver nanocubes stand out from various types of Silver nanostructures (e.g., spheres, rods, bars, belts, and wires) due to their superior performance in a range of applications involvinglocalized surface plasmon resonance, surface-enhanced Raman scattering, and biosensing. In addition, extensive efforts have been devoted to the investigation of Gold-based nanocomposites to achieve high catalytic performances and utilization efficiencies. Furthermore, as the catalytic reactivity of Silver nanostructures depends highly on their morphology, hollow Gold nanoparticles having void interiors may offer additional catalytic advantages due to their increased surface areas. Especially, hollow nanospheres possess structurally tunable features such as shell thickness, interior cavity size, and chemical composition, leading to relatively high surface areas, low densities, and reduced costs compared with their solid counterparts. Thus, hollow-structured noblemetal nanoparticles can be applied to nanometer-sized chemical reactors, efficient catalysts, energy-storage media, and small containers to encapsulate multi-functional active materials. Silver nanocubes dispersed in water have been transformed into Ag@Au nanoboxes, which show highly enhanced catalytic properties, by adding $HAuCl_4$. By using this concept, $SiO_2$-coated Ag@Au nanoboxes have been synthesized via galvanic replacement of $SiO_2$-coated Ag nanocubes. They have lower catalytic ability but more stability than Ag@Au nanoboxes do. Thus, they could be recycled. $SiO_2$-coated Ag@Au nanoboxes have been found to catalyze the degradation of 4-nitrophenol efficiently in the presence of $NaBH_4$. By changing the amount of the added noble metal salt to control the molar ratio Au to Ag, we could tune the catalytic properties of the nanostructures in the reduction of the dyes. The catalytic ability of $SiO_2$-coated Ag@Au nanoboxes has been found to be much more efficient than $SiO_2$-coated Ag nanocubes. Catalytic performances were affected noteworthily by the metals, sizes, and shapes of noble-metal nanostructures.

  • PDF