• 제목/요약/키워드: gadolinium

검색결과 325건 처리시간 0.022초

The Roles of Kupffer Cells in Hepatic Dysfunction Induced by Ischemia/Reperfusion in Rats

  • Jung Joo-Yeon;Lee Sun-Mee
    • Archives of Pharmacal Research
    • /
    • 제28권12호
    • /
    • pp.1386-1391
    • /
    • 2005
  • This study examined the role of Kupffer cells in altering the hepatic secretory and microsomal function during ischemia and reperfusion (ls/Rp). Rats were subjected to 60 min of hepatic ischemia, followed by 1 and 5 h of reperfusion. Gadolinium chloride ($GdCl_{3}$, 7.5 mg/kg body weight, intravenously) was used to inactivate the Kupffer cells 1 day prior to ischemia. Is/Rp markedly increased the serum aminotransferase level and the extent of lipid peroxidation. $GdCl_{3}$ significantly attenuated these increases. Is/Rp markedly decreased the bile. flow and cholate output, and $GdCl_{3}$ restored their secretion. The cytochrome P450 content was decreased by Is/Rp. However, these decreases were not prevented by $GdCl_{3}$. The aminopyrine N-demethylase activity was decreased by Is/Rp, while the aniline p-hydroxylase activity was increased. $GdCl_{3}$ prevented the increase in the aniline p-hydroxylase activity. Overall, Is/Rp diminishes the hepatic secretory and microsomal drug-metabolizing functions, and Kupffer cells are involved in this hepatobiliary dysfunction.

LiCl-KCl 고온 용융염 내 UCl3 및 GdCl3의 전기화학적 거동 연구 (Electrochemical Behavior of UCl3 and GdCl3 in LiCl-KCl Molten Salt)

  • 민슬기;배상은;박용준;송규석
    • 전기화학회지
    • /
    • 제12권3호
    • /
    • pp.276-281
    • /
    • 2009
  • 본 연구는 고온화학공정에 사용할 전기화학적 센서 기술 개발의 사전 연구로서 고온 LiCl-KCl 공융염에 $UCl_3$$GdCl_3$를 녹여 $U^{3+}$$Gd^{3+}$의 전기화학 반응을 조사하였다. $U^{3+}$는 고온 LiCl-KCl 용융염내에서 -0.2V/-0.35 V에서 $U^{4+}$로의 산화/환원반응의, -1.51 V/-1.35 V에서 전착/해리 반응전류의 피크를 나타내었다. $Gd^{3+}$의 경우 -2.15 V에서 전착반응 피크를, -1.9 V에서 산화해리전류 피크를 나타내었다. $U^{3+}$$Gd^{3+}$의 혼합 고온 용융염에서는 $Gd^{3+}$의 전착 피크가 양의 전위로 이동하였다. 일정전류법의 결과는 시간이 지남에 따라 전위값이 일정해졌으며 그 전위값은 전해질 내 반응물의 환원전위값과 일치하였다. 노멀펄스전위법과 직각파전위법은 두 원소의 정성분석을 위한 좋은 전기화학적 방법론임을 보였으며 특히 노멀펄스전위곡선을 미분한 결과는 사용된 다른 방법에 비해 반응전류의 피크분리가 잘 일어났다.

몬테칼로 기법을 이용한 방사선 선량증가 물질에 따른 선량증가 효과 평가 (A Monte Carlo Study of Dose Enhancement according to the Enhancement Agents)

  • 김정훈;김창수;황철환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.93-99
    • /
    • 2017
  • Monte Carlo 시뮬레이션을 이용하여 MV X, ${\gamma}$선에서의 선량증가 효과를 평가하였다. MCNPX code를 이용하여 ICRU 평판형(Slab) 모의피폭체를 전산모사하였으며, 입사 광자의 에너지, 선량증가 물질의 종류 및 농도에 따른 영향을 분석하였다. 선량증가 물질은 금(aurum), 가돌리늄(gadolinium), 요오드(iodine), 산화철(iron oxide)에 대해 비교 평가하였으며, 입사에너지는 선형가속기에서 발생된 4, 6, 10, 15 MV X선의 스펙트럼과 Co 60의 ${\gamma}$선원을 사용하였다. 모의피폭체 내에 7, 18, 30 mg/g 농도의 물질을 삽입하였으며, 선량증가 효과의 정량적 평가를 위해 선량증가비를 산출하였다. X선의 입사에너지가 낮을수록, 선량증가 물질의 농도가 높을수록 높은 선량증가비를 나타내었으며, 최대 선량증가비는 금 1.079, 가돌리늄 1.062, 요오드 1.049, 산화철 1.035를 보여 금, 가돌리늄, 요오드, 산화철 입자 순으로 높은 선량증가 효과를 보였다. 이러한 결과는 In-vivo, vitro 연구의 기초자료로 활용할 수 있을 것으로 사료된다.

전자빔 증착 열차폐 코팅용 란타늄-가돌리늄 지르코네이트(La2O3-Gd2O3-ZrO2계) 세라믹 잉곳의 제조공정에 따른 열충격 저항성 (Thermal Shock Resistance According to the Manufacturing Process of Lanthanum Gadolinium Zirconate Ceramic Igot for Thermal Barrier Coating by Electron Beam in the La2O3-Gd2O3-ZrO2 System)

  • 최선아;채정민;김성원;이성민;한윤수;김형태;장병국;오윤석
    • 한국표면공학회지
    • /
    • 제50권6호
    • /
    • pp.465-472
    • /
    • 2017
  • The ingot fabrication conditions related with the thermal shock bearing phase and microstructure have investigated for the rare earth zirconate ceramic material, lanthanum gadolinium zirconate, as a thermal barrier coating using electron beam evaporation method. The thermal shock resistance of the prepared ingot was evaluated by high energy electron beam irradiation. The rare earth zirconate ceramic powder was prepared by controlling the raw material powder composition of $La_2O_3$, $Gd_2O_3$ and $ZrO_2$ so as to have a composition of $(La_{0.3}Gd_{0.7})_2Zr_2O_7$ which was selected from the former study. Ingot samples were prepared under two conditions. The first condition is prepared by sintering the prepared powder mixture to form an ingot. The second condition is prepared by calcining the prepared powder mixture to form a composite phase and then sintering to form an ingot. X-ray diffraction(XRD) and Scanning Electron Microscope(SEM) were used to analyze phase forming behavior and microstructure of ingot samples. Nanoindentation method used to obtain elastic modulus and hardness of each ingot specimen. Also the stress distribution of ingot was simulated by using FEM method assuming the ingot surface was exposed to electron beam. As a results, in the case of an ingot having a network-shaped microstructure in which relatively coarse pores are included, it seems that the thermal shock resistance was higher than in the case of an ingot having a microstructure composed of relatively fine grains only or particles with the similar level size when the high energy electron beam irradiation.

MV X선의 방사선 선량 증강 현상에서 물리적 특성과 이차입자의 발생 (Characterization of Physical Processes and Secondary Particle Generation in Radiation Dose Enhancement for Megavoltage X-rays)

  • 황철환;김정훈
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.791-799
    • /
    • 2019
  • 선량 증강 현상에서 발생하는 물리적 특성과 증강 물질과의 상호 작용으로부터 발생하는 이차입자 생성을 평가하였다. Geant 4, MIRD 두부 팬텀을 이용한 몬테카를로 전산 모사를 진행하였으며, 선형가속기에서 발생되는 4, 6, 10, 15, 18, 25 MV X선을 선원으로 적용하였다. 10, 20, 30 mg/g의 금(aurum), 가돌리늄(gadolinium) 증강 물질을 팬텀 내부 종양에 모사하였으며, 물리적 상호작용의 변화와 이차입자 발생에 따른 입자플루언스와 초기 에너지로부터 방사선가중인자를 고려하여 등가선량을 평가하였다. 방사선 선량 증강 물질에 의한 상호작용은 고 원자번호에서 기인하여 광전효과에 의한 에너지 흡수를 높이는 것으로 나타났으며, 10 MV 이상의 에너지에서는 광핵반응의 증가를 나타내었다. 이로 인해, 팬텀 내부에서 양성자, 중성자와 같은 이차입자 발생의 증가를 보였으며, 중성자에 의한 등가선량이 최대 424.2배 증가하는 것으로 나타났다. 본 연구는 선량 증강 현상에서의 에너지 전달, 흡수의 물리적 과정을 모사하여, 증강 현상에서 발생하는 물리적 특성을 분석하고자 하였다. 이러한 결과는 향후 in-vivo, in-vitro 선량 증강 실험을 위한 기초 자료로 활용될 수 있을 것으로 사료된다.

부산 하수처리장에서 공정별 용존 희토류 원소의 농도 및 인위적 기원 가돌리늄의 배출량 평가 (Assessments of Dissolved Rare Earth Elements and Anthropogenic Gadolinium Concentrations in Different Processes of Wastewater Treatment Plant in Busan, Korea)

  • 임이진;류종식;이준엽;이준호;조형미;김태진
    • 한국지구과학회지
    • /
    • 제43권2호
    • /
    • pp.303-311
    • /
    • 2022
  • 자기공명영상(MRI) 장비의 조영제로 흔히 사용되는 가돌리늄(Gd)은 매우 안정된 상태로 하수처리과정에서 거의 제거되지 않고 수환경으로 유입된다고 알려져 있다. 따라서 본 연구에서는 세 가지의 공법으로 하수처리를 하는 부산 수영 하수처리장에서 채취한 하수 시료의 공정별 용존 희토류 원소의 제거율 및 수환경으로 배출되는 인위적 기원 Gd(Gdanth)의 배출량을 평가하고자 하였다. 용존 희토류 원소는 공정별 처리 단계에 따라 무거운 희토류 원소(Tb-Lu)에 비해 가벼운 희토류 원소(La-Eu)에서 농도가 감소하는 경향을 보였다. 또한 일부 시료에서 나타난 음의(negative) Sm anomaly (<1)는 생물학적 제거 과정에서 Sm이 입자나 인산염과 흡착되어 함께 제거되었을 가능성을 시사한다. 모든 시료에서 양의(positive) Gd anomaly (149±50, n=9)를 보였으며, 공정별로 측정된 Gd의 총 농도 중 Gdanth은 약 97% 이상을 차지하는 것으로 나타났다. 이는 하수처리과정에서 Gdanth 이 거의 제거되지 않고 수영강 하류로 배출된다는 것을 의미한다. 일별 처리용량을 고려하여 각 공정에서 배출되는 Gdanth의 배출량은 259 mmol/day로 추정할 수 있다. 본 연구의 결과는 하수처리장을 통해 수영만 연안으로 Gdanth이 지속적으로 배출될 것으로 예상되며, 향후 Gd의 중장기적인 관측이 필요함을 시사한다.

열이온화 질량분석기를 이용한 Gd 동위원소 측정에서 동중원소 영향 (The isobaric effect on the measurement of Gd isotopes by thermal ionization mass spectrometry)

  • 전영신;박종호;조기수;한선호;송규석
    • 분석과학
    • /
    • 제22권5호
    • /
    • pp.415-421
    • /
    • 2009
  • 열 이온화 질량분석기를 이용한 가돌리늄 동위원소 비 측정에서 동중원소 영향에 대하여 실험했다. 특히 $^{155}Gd/^{158}Gd$ 측정값은 자연 동위원소 비 보다 높게 측정될 뿐만 아니라 시간에 따라 이 비가 감소하는 현상을 보였다. 이것은 Gd 시료 중 미량의 La 불순물이 산화상태($^{139}La^{16}O^+$, m/z=155)로 존재하여 $^{155}Gd$ 동위원소에 동중원소 영향을 미쳐 이의 측정값이 높게 나오는 현상으로 판단된다. 또한 Gd 보다 La이 용융점과 이온화 에너지가 낮기 때문에 초기에 $LaO^+$가 많이 생성되고 시간에 따라 소멸되므로 $^{155}Gd/^{158}Gd$ 값이 감소하는 것으로 생각된다. 레늄필라멘트 중 Gd 동위원소에 영향을 주는 불순물로 Ba ($BaO^+$), Ce ($CeO^+$), Sm ($SmO^+$), La ($LaO^+$) 그리고 $K_4{^+}$ (m/z=156) 클러스터 등이 있는 것으로 확인되었으나, 이러한 원소들은 필라멘트를 진공 가열시켜 줌으로 동중원소 영향을 없앨 수 있었다. 또한 La, Ce, Ba 등에 의한 동중원소 영향이 매우 크기 때문에 이런 시료는 Yb, Sm, Dy, Er, Lu 등의 방해원소가 없거나 극히 작다면 $Gd^+$ 금속이온을 직접 측정하는 것 보다 산화상태인 $GdO^+$ 이온으로 동위원소 비를 측정하고 산소 동위원소 비를 보정해 주는 방법을 사용함으로 동중원소 영향을 피할 수 있는 방법임을 알 수 있었다.

Quantitative T1 Mapping for Detecting Microvascular Obstruction in Reperfused Acute Myocardial Infarction: Comparison with Late Gadolinium Enhancement Imaging

  • Jae Min Shin;Eui-Young Choi;Chul Hwan Park;Kyunghwa Han;Tae Hoon Kim
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.978-986
    • /
    • 2020
  • Objective: To compare native and post-contrast T1 mapping with late gadolinium enhancement (LGE) imaging for detecting and measuring the microvascular obstruction (MVO) area in reperfused acute myocardial infarction (MI). Materials and Methods: This study included 20 patients with acute MI who had undergone 1.5T cardiovascular magnetic resonance imaging (CMR) after reperfusion therapy. CMR included cine imaging, LGE, and T1 mapping (modified look-locker inversion recovery). MI size was calculated from LGE by full-width at half-maximum technique. MVO was defined as an area with low signal intensity (LGE) or as a region of visually distinguishable T1 values (T1 maps) within infarcted myocardium. Regional T1 values were measured in MVO, infarcted, and remote myocardium on T1 maps. MVO area was measured on and compared among LGE, native, and post-contrast T1 maps. Results: The mean MI size was 27.1 ± 9.7% of the left ventricular mass. Of the 20 identified MVOs, 18 (90%) were detected on native T1 maps, while 10 (50%) were recognized on post-contrast T1 maps. The mean native T1 values of MVO, infarcted, and remote myocardium were 1013.5 ± 58.5, 1240.9 ± 55.8 (p < 0.001), and 1062.2 ± 55.8 ms (p = 0.169), respectively, while the mean post-contrast T1 values were 466.7 ± 26.8, 399.1 ± 21.3, and 585.2 ± 21.3 ms, respectively (p < 0.001). The mean MVO areas on LGE, native, and post-contrast T1 maps were 134.1 ± 81.2, 133.7 ± 80.4, and 117.1 ± 53.3 mm2, respectively. The median (interquartile range) MVO areas on LGE, native, and post-contrast T1 maps were 128.0 (58.1-215.4), 110.5 (67.7-227.9), and 143.0 (76.7-155.3) mm2, respectively (p = 0.002). Concordance correlation coefficients for the MVO area between LGE and native T1 maps, LGE and post-contrast T1 maps, and native and post-contrast T1 maps were 0.770, 0.375, and 0.565, respectively. Conclusion: MVO areas were accurately delineated on native T1 maps and showed high concordance with the areas measured on LGE. However, post-contrast T1 maps had low detection rates and underestimated MVO areas. Collectively, native T1 mapping is a useful tool for detecting MVO within the infarcted myocardium.

Late Gadolinium Enhancement of Left Ventricular Papillary Muscles in Patients with Mitral Regurgitation

  • Su Jin Lim;Hyun Jung Koo;Min Soo Cho;Gi-Byoung Nam;Joon-Won Kang;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1609-1618
    • /
    • 2021
  • Objective: Arrhythmogenic mitral valve prolapse (MVP) is an important cause of sudden cardiac death characterized by fibrosis of the papillary muscles or left ventricle (LV) wall, and an association between late gadolinium enhancement (LGE) of the LV papillary muscles and ventricular arrhythmia in MVP has been reported. However, LGE of the papillary muscles may be observed in other causes of mitral regurgitation, and it is not limited to patients with MVP. This study was to evaluate the association of LGE of the LV papillary muscles or ventricular wall on cardiac magnetic resonance imaging (CMR) and ventricular arrhythmia in patients with mitral regurgitation. Materials and Methods: This study included 88 patients (mean age ± standard deviation, 58.3 ± 12.0 years; male, 42%) with mitral regurgitation who underwent CMR. They were allocated to the MVP (n = 43) and non-MVP (n = 45) groups, and their LGE images on CMR, clinical characteristics, echocardiographic findings, and presence of arrhythmia were compared. Results: LV myocardial wall enhancement was more frequent in the MVP group than in the non-MVP group (28% vs. 11%, p = 0.046). Papillary muscle enhancement was observed in 7 (7.9%) patients. Of the 43 patients with MVP, 15 (34.8%) showed LGE in the papillary muscles or LV myocardium, including 12 (27.9%) with LV myocardial wall enhancement and 4 (9.3%) with papillary muscle enhancement. One patient with bilateral diffuse papillary muscle enhancement experienced sudden cardiac arrest due to ventricular fibrillation. Univariable logistic regression analysis showed that high systolic blood pressure (BP; odds ratio [OR], 1.05; 95% confidence interval [CI], 1.01-1.09; p = 0.027) and ventricular arrhythmia (OR, 6.84; 95% CI, 1.29-36.19; p = 0.024) were significantly associated with LGE of the papillary muscles. Conclusion: LGE of the papillary muscles was present not only in patients with MVP, but also in patients with other etiologies of mitral regurgitation, and it was associated with high systolic BP and ventricular arrhythmia. Papillary muscle enhancement on CMR should not be overlooked.

Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy

  • Min Jae Cha;Iksung Cho;Joonhwa Hong;Sang-Wook Kim;Seung Yong Shin;Mun Young Paek;Xiaoming Bi;Sung Mok Kim
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1044-1053
    • /
    • 2021
  • Objective: Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadolinium-enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM). Materials and Methods: Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5-61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing moco-ss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test. Results: The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785). Conclusion: Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.