• Title/Summary/Keyword: gadolinium

Search Result 328, Processing Time 0.028 seconds

Void Reactivity of DUPIC Fuel Bundle

  • Hari P. Gupta;Park, Hangbok;Bo W. Rhee;Park, Hyungsoo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.52-57
    • /
    • 1996
  • The coolant void reactivity is positive for CANDU reactor loaded with DUPIC fuel which has more fissile content compared to natural uranium. A parametric study was done to reduce the void reactivity of the fuel bundle and loss in discharge burnup was estimated. It is observed that the burnable absorbers like gadolinium, boron, europium are not able to keep the reduction in void reactivity uniform throughout fuel burnup. Dysprosium and erbium can keep the void reactivity reduction uniform throughout. fuel burnup but toss in discharge burnup for erbium case is more compared to that of dysprosium case.

  • PDF

Multi-Parametric Quantitative MRI for Measuring Myelin Loss in Hyperglycemia-Induced Hemichorea

  • Youn, Sung Won;Kwon, Oh Dae;Hwang, Moon Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.148-156
    • /
    • 2019
  • Hyperglycemia-induced hemichorea (HGHC) is a rare but characteristic hyperkinetic movement disorder involving limbs on one side of the body. In a 75-year-old woman with a left-sided HGHC, conventional brain MR imaging showed very subtle T1-hyperintensity and unique gadolinium enhancement in the basal ganglia contralateral to movements. Multi-parametric MRI was acquired using pulse sequence with quantification of relaxation times and proton density by multi-echo acquisition. Myelin map was reconstructed based on new tissue classification modeling. In this case report of multi-parametric MRI, quantitative measurement of myelin change related to HGHC in brain structures and its possible explanations are presented. This is the first study to demonstrate myelin loss related to hyperglycemic insult in multi-parametric quantitative MR imaging.

Recurrent Painful Ophthalmoplegic Neuropathy: a Case Report

  • Park, Jae Hwi;Lee, Ho Kyu;Koh, Myeong Ju;Oh, Jung Hwan;Park, Sung Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.172-174
    • /
    • 2019
  • Upon review, it is noted that recurrent painful ophthalmoplegic neuropathy (RPON) is a rare neurological syndrome characterized by recurrent unilateral headaches and painful ophthalmoplegia of the ipsilateral oculomotor nerve. As seen on brain MRI, thickening and enhancement of the oculomotor cranial nerve can be observed in these cases. We experienced a case of RPON in an adult patient who showed thickening and enhancement of the oculomotor nerve on gadolinium-enhanced 3D-FLAIR image. The authors report a case of RPON with a review of the literature.

Arachnoid Granulations Mimicking Multiple Osteolytic Bone Lesions in the Occipital Bone

  • Park, Seong-Hyun;Park, Ki-Su;Hwang, Jeong-Hyun
    • Brain Tumor Research and Treatment
    • /
    • v.6 no.2
    • /
    • pp.68-72
    • /
    • 2018
  • We report a rare case of arachnoid granulations mimicking multiple osteolytic bone lesions. A 66-year-old woman was admitted to a local clinic for a regular checkup. Upon admission, brain CT showed multiple osteolytic lesions in the occipital bone. These needed to be differentiated from multiple osteolytic bone tumor. Subsequent brain MRI revealed that the osteolytic lesions were isointense to cerebrospinal fluid, hyperintense on T2-weighted image, hypointense on T1-weighted image, and with subtle capsules around the osteolytic lesions that were visible after gadolinium injection. A bone scan revealed no radiotracer uptake. The lesions were in both the transverse sinuses and the torcular herophili. With typical radiological appearances of the lesions, the osteolytic lesions were diagnosed as multiple arachnoid granulations. No further treatment was planned. A 1-year follow-up brain CT scan revealed no change. We should consider the possibility of arachnoid granulations when multiple osteolytic lesions are observed in the occipital bone.

[ $Gd_2O_3:Eu$ ] System: Structural Study of the Influence of Luminescence Center Concentration

  • Rabanal, M.E.;Gomez, L.;Khalifa, A.;Mancic, L.;Milosevic, O.;Torralba, J.M.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.668-669
    • /
    • 2006
  • The influence of $Eu^{3+}$ doping on the structural and morphological properties of the $Gd_2O_3:Eu^{3+}$ phosphor system, obtained ultrasonically via Spray Pyrolysis from common gadolinium and europium nitrate solutions, was studied. The particle morphology, crystalline and chemical structure were studied by XRD, SEM and EDS. TEM was applied in order to identify the structure and growth of "primary nanoparticles" and determine the presence of domains locally affected by "Moires Frames" and "Crystallite Size". The SADP allows determining the presence of a polycrystalline material with two phases in the "as-prepared" samples, and only an Ia3 phase along the thermal treatment.

  • PDF

Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence (MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • In this paper, we introduce how to change the reaction rate as mol concentration when we scan enhanced MRI with GBCA(Gadolinium Based Contrast Agent), Also show the changing patterns depending on diverse MRI sequences which are made by different physical principle. For this study, we made MRI phantom ourselves. We mixed 500 mmol Gadoteridol with Saline in each 28 different containers from 500 to 0 mmol. After that, MR phantom was scanned by physically different MRI sequences which are T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE and 3D SPCIR in 1.5T bore. The results were as follows : *T1 Spin echo's Total SI(Signal Intensity) was 15608.7, Max peak was 1352.6 in 1 mmol. *T2 FLAIR's Total SI was 9106.4, Max peak was 0.4 1721.6 in 1 mmol. *T1 FLAIR's Total SI was 20972.5, Max peak was 1604.9 in 1 mmol. *3D FLASH's Total SI was 20924.0, Max peak was 1425.7 in 40 mmol. *3D SPACE 1mm's Total SI was 6399.0, Max peak was 528.3 in 3 mmol. *3D SPACE 5mm's Total SI was 6276.5, Max peak was 514.6 in 2 mmol. *3D SPCIR's Total SI was 1778.8, Max peak was 383.8 in 0.4 mmol. In most sequences, High signal intensity was shown in diluted lower concentration rather than high concentration, And also graph's max peak and pattern had difference value according to the each different sequence. Through this paper which have quantitative result of GBCA's reaction rate depending on sequence, We expect that practical enhanced MR protocol can be performed in clinical field.

Image Comparisons using a Diethylenetriaminetriacetic Acid Derivative and Gd-DTPA (Diethylenetriaminetriacetic acid 유도체와 Gd-DTPA와의 영상비교)

  • Cho, Jung-Keun;Lee, Chai-Ho;Han, Tae-Jong;Lim, Cheong-Hwan;Kim, Jung-Nam;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.210-216
    • /
    • 2008
  • In this study, image comparisons were carried out using a MRI contrast medium which was derived by mixing a polyaminocarboxylic ligand and a gadolinium (III) transition metal which is paramagnetic and has good neutron absorbing capabilities with Gd-DTPA which is currently being used widely in the clinical setting. By using a 1.0T (Harmony, SIEMENS) MR equipment, phantoms of which 100cc of saline was diluted with a diethylenetriaminetriacetic acid derivative and Gd-DTPA were imaged. The amount of diethylenetriaminetriacetic acid and Gd-DTPA which was diluted into the 100cc of saline was 0.05mmol/L, 0.1mmol/L, 0.15mmol/L, 0.2mmol/L, 0.3mmol/L, 0.5mmol/L, 1.0mmol/L, 2.0mmol/L, 3.0mmol/L and 4.9mmol/L respectively. Head coils were used and while fixing the SE pulse sequence and image variable (as TE is 14ms, 1NEX with a 256x201 matrix), the signal intensity and simple contrast ratios according to changing concentrations and TR were compared with various TR at 300ms, 400ms, 500ms, 600ms, 700ms, 800ms, 900ms, 1000ms, 1200ms, 1400ms and 1600ms. According to the comparison results of the signal intensity of the image based on changes in contrast medium concentrations and TR, the differences in signal intensity between the two contrast mediums were found to be small at $1.0{\sim}2.0mmol/L$ when the highest signal intensity was achieved. However, at concentrations of 1.0mmol/L or less, the signal intensity was markedly higher in the Diethylenetriaminetriacetic acid derivative than in the Gd-DTPA complex. It was also found that the differences in the signal intensities demonstrated by the concentrations of the contrast mediums were affected by the TR. Accordingly, the efficacy of the Diethylenetriaminetriacetic acid derivative was shown to be better than the Gd-DTPA and also possible to get the optimum image quality by the use of an appropriate TR with appropriate concentrations of contrast medium.

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

Electrical Characterization of Ultrathin Film Electrolytes for Micro-SOFCs

  • Shin, Eui-Chol;Ahn, Pyung-An;Jo, Jung-Mo;Noh, Ho-Sung;Hwang, Jaeyeon;Lee, Jong-Ho;Son, Ji-Won;Lee, Jong-Sook
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.5
    • /
    • pp.404-411
    • /
    • 2012
  • The reliability of solid oxide fuel cells (SOFCs) particularly depends on the high quality of solid oxide electrolytes. The application of thinner electrolytes and multi electrolyte layers requires a more reliable characterization method. Most of the investigations on thin film solid electrolytes have been made for the parallel transport along the interface, which is not however directly related to the fuel cell performance of those electrolytes. In this work an array of ion-blocking metallic Ti/Au microelectrodes with about a $160{\mu}m$ diameter was applied on top of an ultrathin ($1{\mu}m$) yttria-stabilized-zirconia/gadolinium-doped-ceria (YSZ/GDC) heterolayer solid electrolyte in a micro-SOFC prepared by PLD as well as an 8-${\mu}m$ thick YSZ layer by screen printing, to study the transport characteristics in the perpendicular direction relevant for fuel cell operation. While the capacitance variation in the electrode area supported the working principle of the measurement technique, other local variations could be related to the quality of the electrolyte layers and deposited electrode points. While the small electrode size and low temperature measurements increaseed the electrolyte resistances enough for the reliable estimation, the impedance spectra appeared to consist of only a large electrode polarization. Modulus representation distinguished two high frequency responses with resistance magnitude differing by orders of magnitude, which can be ascribed to the gadolinium-doped ceria buffer electrolyte layer with a 200 nm thickness and yttria-stabilized zirconia layer of about $1{\mu}m$. The major impedance response was attributed to the resistance due to electron hole conduction in GDC due to the ion-blocking top electrodes with activation energy of 0.7 eV. The respective conductivity values were obtained by model analysis using empirical Havriliak-Negami elements and by temperature adjustments with respect to the conductivity of the YSZ layers.

Acute Adverse Reactions to Gadolinium-based Intravenous Contrast Agents for MRI : Retrospective Analysis Using Computed Reporting System (자기공명영상검사용 가돌리늄 경정맥 조영제의 급성 부작용: 부작용 전산 체계를 이용한 후향적 분석)

  • Choi, Moon-Hyung;Choi, Joon-Il;Jung, Seung-Eun;Ahn, Kook-Jin;Lee, Hae-Giu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2011
  • Purpose : To assess the frequency and severity of acute adverse reactions to intravenous administration of gadolinium-based contrast agents using computerized reporting system at a single large academic institution. Materials and Methods : We assessed data from electronic hospital information system from October 2008 to December 2010. Reactions were classified as mild, moderate, or severe. We compared the frequency of adverse reactions among three contrast agents (Gd-BT-DO3A, Gd-DTPA and Gd-EOB-DTPA). Results : The total number of administrated contrast agents was 33,600, and the number of administration of Gd-BT-DO3A, Gd-DTPA and Gd-EOB-DTPA were 20,824 (62%), 10,417 (31%) and 2,359 (7%), respectively. Total 39 adverse reactions were reported accounting for 0.1161% of all administrations. The incidences of adverse reactions were 0.1248% (26/39, 67%) for Gd-BT-DO3A, 0.0768% (8/39, 21%) for Gd-DTPA, and 0.2120% (5/39, 13%) for Gd-EOB-DTPA. The difference of frequencies of adverse reaction among three contrast agents was not significant. Most cases of the adverse effect were mild (35/39, 89.7%). Moderate and severe adverse reactions were encountered in two patients, respectively. Conclusion : Among Koreans, adverse effects were rare, and especially, moderate to severe adverse reactions were much rarer. There was no difference among the frequencies of adverse reactions caused by three different contrast agents.