• Title/Summary/Keyword: fuzzy supervisory control

Search Result 31, Processing Time 0.021 seconds

PDA-based Supervisory Control of Mobile Robots (PDA를 이용한 이동로봇 제어)

  • 정성호;김성주;김용택;전홍태
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.105-108
    • /
    • 2002
  • This paper represents the mobile robot control system remote controlled by PDA(personal digital assistance). So far, owing to the development of internet technologies, lots of remote control methods through internet have been proposed. To control a mobile robot through internet and guide it under unknown environment, We propose a control method activated by PDA. In a proposed system, PDA acts as a user interface to communicate with notebook as a controller of the mobile robot system using TCP/IP protocol, and the notebook controls the mobile robot system. The information about the direction and velocity of the mobile robot feedbacks to the PDA and the PDA send new control method produced from the fuzzy inference engine.

  • PDF

A study of predictive fuzzy control logic-based elevator group controller (예견퍼지 제어논리를 기반으로 하는 엘리베이터 군제어기의 연구)

  • Choi, Don;Park, Hee-Chul;Park, Ji-Hyun;Woo, Kwang-Bang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.857-862
    • /
    • 1992
  • An elevator group supervisory control logic is investigated to supervise multiple elevators, ensuring their efficient operations. In this paper, a predictive fuzzy control logic of group elevator system is developed for coping with multiple control objects and uncertainty of system state. Simulation of this control logic shows considerable improvements of system performance by the reduction of average waiting time and long wait rate.

  • PDF

Predictive Fuzzy Control for Elevator Group Supervisory System

  • Park, Don-;Park, Chul-;Woo, Kwang-Bang
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1374-1377
    • /
    • 1993
  • In this paper, a predictive fuzzy control algorithm to supervise the elevator system with plural elevator cars is developed and its performance is evaluated. Elevator group controller must decide which of the cars is suitable for responding the registered hall call and allocate it to the selected car controller. In most cases, the purpose of group control is to minimize waiting time of passengers and occurrence of long wait as much as possible. The proposed algorithm ensures the efficient operations of the group cars and provides the improved level of service, coping with multiple control objects and uncertainty of system state. The feasibility of the proposed control algorithm is evaluated by graphic simulator on computer.

  • PDF

Fuzzy Logic Based Energy Management For Wind Turbine, Photo Voltaic And Diesel Hybrid System

  • Talha, Muhammad;Asghar, Furqan;Kim, Sung Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.351-360
    • /
    • 2016
  • Rapid population growth with high living standards and high electronics use for personal comfort has raised the electricity demand exponentially. To fulfill this elevated demand, conventional energy sources are shifting towards low production cost and long term usable alternative energy sources. Hybrid renewable energy systems (HRES) are becoming popular as stand-alone power systems for providing electricity in remote areas due to advancement in renewable energy technologies and subsequent rise in prices of petroleum products. Wind and solar power are considered feasible replacement to fossil fuels as the prediction of the fuel shortage in the near future, forced all operators involved in energy production to explore this new and clean source of power. Presented paper proposes fuzzy logic based Energy Management System (EMS) for Wind Turbine (WT), Photo Voltaic (PV) and Diesel Generator (DG) hybrid micro-grid configuration. Battery backup system is introduced for worst environmental conditions or high load demands. Dump load along with dump load controller is implemented for over voltage and over speed protection. Fuzzy logic based supervisory control system performs the power flow control between different scenarios such as battery charging, battery backup, dump load activation and DG backup in most intellectual way.

A Fuzzy-Logic Controller for an Electrically Driven Steering System for a Motorcar

  • Lee, Sang-Heon;Kim, Il-Soo;Jayantha katupitiya
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.8
    • /
    • pp.1039-1052
    • /
    • 2002
  • This paper presents an application where a Fuzzy-Logic Controller (FLC) is used at a supervisory level to implement mutual coordination of the steering of the two front wheels of a motorcar. The two front wheels are steered by two independent discrete time state feedback controllers with a view to optimize the steering slip angles. The functions of the two controllers are tied together by way of a FLC. Because of the presence of unmodelled dynamics and disturbances acting on the two sides, it is difficult to achieve the desired performance using conventional control systems. This is the primary reason that FLC is emploged to solve the problem. The results show that the implemented system achieved desired coupling between the two independent systems and thereby reduces the difference between the two steered angles.

An Adaptive Fuzzy Backstepping Approach to Robust Tracking Control of a Single-Link Flexible Joint Robot (적응형 퍼지 백스테핑 방식을 이용한 단일축 유연관절 로봇의 강인 제어)

  • 김은태;이희진
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.4
    • /
    • pp.1-12
    • /
    • 2004
  • This paper presents an adaptive fuzzy backstepping (AFB) controller for a single-link flexible joint robot in the Presence of Parametric uncertainties and external disturbances. Adaptive fuzzy logic systems are used as universal approximators to counteract the model uncertainties coming from robot dynamics and to compensate for the nonlinearities coming from adaptive backstepping method. The approach suggested herein does not require neither an additional supervisory nor a robustifying controller and guarantees that tracking error is uniformly ultimately bounded (UUB) within a sufficiently small residual set. Finally, a simulation result is given to demonstrate the robust tracking performance of proposed design method.

A Design of Power Management and Control System using Digital Protective Relay for Motor Protection, Fault Diagnosis and Control (모터 보호, 고장진단 및 제어를 위한 디지털 보호계전기 활용 전력감시제어 시스템 설계)

  • Lee, Sung-Hwan;Ahn, Ihn-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.516-523
    • /
    • 2000
  • In this paper, intelligent methods using digital protective relay in power supervisory control system is developed in order to protect power systems by means of timely fault detection and diagnosis during operation for induction motor which has various load environments and capacities in power systems. The spectrum pattern of input currents was used to monitor to state of induction motors, and by clustering the spectrum pattern of input currents, the newly occurrence of spectrums pattern caused by faults were detected. For diagnosis of the fault detected, the fuzzy fault tree was derived, and the fuzzy relation equation representing the relation between an induction motor fault and each fault type, was solved. The solution of the fuzzy relation equation shows the possibility of each fault's occurring. The results obtained are summarized as follows: 1) The test result on the basis of KEMC1120 and IEC60255, show that the operation time error of the digital motor protective relay is improved within ${\pm}5%$. 2) Using clustering algorithm by unsupervisory learning, an on-line fault detection method, not affected by the characteristics of loads and rates, was implemented, and the degree of dependency by experts during fault detection was reduced. 3) With the fuzzy fault tree, fault diagnosis process became systematic and expandable to the whole system, and the diagnosis for sub-systems can be made as an object-oriented module.

  • PDF

PDA-based Supervisory Control of Mobile Robot (PDA를 이용한 이동로봇 제어)

  • Kim, Seong-Joo;Jung, Sung-Ho;Kim, Yong-Taek;Jeon, Hong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.4
    • /
    • pp.379-384
    • /
    • 2002
  • This paper represents the mobile robot system remote controlled by PDA(personal digital assistance). So far, owing to the development of internet technologies, lots of remote control methods through internet have been proposed. To control a mobile robot through internet and guide it under unknown environment, We propose a control method activated by PDA. In a proposed system, PDA acts as a user interface to communicate with notebook as a controller of the mobile robot system using TCP/IP protocol, and the notebook controls the mobile robot system. The information about the direction and velocity of the mobile robot feedbacks to the PDA and the PDA send new control method produced from the fuzzy inference engine.

A Quantitative Vigilance Measuring Model by Fuzzy Sets Theory in Unlimited Monitoring Task

  • Liu, Cheng-Li;Uang, Shiaw-Tsyr;Su, Kuo-Wei
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.176-183
    • /
    • 2005
  • The theory of signal detection has been applied to a wide range of practical situation for a long time, including sonar detection, air traffic control and so on. In general, in this theory, sensitivity parametric index d' and bias parametric index $\beta$ are used to evaluated the performance of vigilance. These indices use observer's response "hit" and "false alarm" to explain and evaluate vigilance, but not considering reaction time. However, the reaction time of detecting should be considered in measuring vigilance in some supervisory tasks such as unlimited monitoring tasks (e.g., supervisors in nuclear plant). There are some researchers have used the segments of reaction time to generate a pair of probabilities of hit and false alarm probabilities and plot the receiver operating characteristic curve. The purpose of this study was to develop a quantitative vigilance-measuring model by fuzzy sets, which combined the concepts of hit, false alarm and reaction time. The model extends two-values logic to multi-values logic by membership functions of fuzzy sets. A simulated experiment of monitoring task in nuclear plant was carried out. Results indicated that the new vigilance-measuring model is more efficient than traditional indices; the characteristics of vigilance would be realized more clearly in unlimited monitoring task.

A Study on Fault Diagnosis of Power System Using Fuzzy Petri Nets (퍼지 페트리네트를 이용한 전력계통 고장진단에 관한 연구)

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.122-124
    • /
    • 2000
  • As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. Therefore this paper proposes a method of the modeling of protection systems and fault diagnosis in power systems using Fuzzy Petri Nets (FPN). The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method can cover online processing of real-time data from SCADA (Supervisory Control and Data Acquisition).

  • PDF