• Title/Summary/Keyword: fusion index

Search Result 232, Processing Time 0.02 seconds

A Study of Cycling Exercise which uses a Target Heart Beat for Cardiorespiratory Function Improvement (목표심박수를 이용한 자전거 운동의 심폐능력 향상 연구)

  • Kim, Sung-Min;Kang, Seung-Ho;Lee, Man-Pyo;Jung, Whoi-Seong;Jang, Won-Seuk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.35-43
    • /
    • 2008
  • In this study we confirmed for the cardiopulmonary ability improvement of the cycling exercise which uses a target heart beat. Consequently, we looked the resting systolic blood pressure down at 2.98% and THBI(Total Heart Beat Index) also decrements at 7.59%. But, increase of $VO_2$ max and PTT(Pulse Transit Time)were each point 24.60% and 4.92%. Increase of $VO_2$ max showed the growth of stroke volume by myocardial development. The increase of a stroke volume induces the decrease of Heart rate. The blood pressure was reduced also though the blood of many quantity was supplied at the artery. The reason is the phenomenon to be due to by an elasticity increase of the artery. We found out it through the decrease of PTT. So the cycling exercise to use consequently the target heart beat will become big aid at the health care.

Five Indices of SSaM-GG(=Smart, Shared, and Mutual- Green Growth) for Sustainable Development (지속가능/영속(永續)발전을 위한 지속성/안녕(安寧)성의 5대 지표(=SSaM-GG) 개발)

  • Koo, Ja-Kong;Park, Sang Ryul;Lee, Seul Ki
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.127-133
    • /
    • 2012
  • The 'SSaM-GG'(=Smart, Shared, and Mutual- Green Growth) as the five bottom lines for sustainable development is developed and suggested. Because the name of Green Growth alone is not sufficient for clear conceptualization, implementation. and etc. For the global harmonized usage & application, the Eastern-Western conceptual fusion has been performed, and verified for more than 12 years on the worldwide successes and failures.

URBAN ENVIRONMENTAL QUALITY ANALYSIS USING LANDSAT IMAGES OVER SEOUL, KOREA

  • Lee, Kwon-H.;Wong, Man-Sing;Kim, Gwan-C.;Kim, Young-J.;Nichol, Janet
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.556-559
    • /
    • 2007
  • The Urban Environmental Quality (UEQ) indicates a complex and various parameters resulting from both human and natural factors in an urban area. Vegetation, climate, air quality, and the urban infrastructure may interact to produce effects in an urban area. There are relationships among air pollution, vegetation, and degrading environmental the urban heat island (UHI) effect. This study investigates the application of multi-spectral remote sensing data from the Landsat ETM and TM sensors for the mapping of air quality and UHI intensity in Seoul from 2000 to 2006 in fine resolution (30m) using the emissivity-fusion method. The Haze Optimized Transform (HOT) correction approach has been adopted for atmospheric correction on all bands except thermal band. The general UHI values (${\Delta}(T_{urban}-T_{rural})$) are 8.45 (2000), 9.14 (2001), 8.61 (2002), and $8.41^{\circ}C$ (2006), respectively. Although the UHI values are similar during these years, the spatial coverage of "hot" surface temperature (>$24^{\circ}C$) significantly increased from 2000 to 2006 due to the rapid urban development. Furthermore, high correlations between vegetation index and land surface temperature were achieved with a correlation coefficients of 0.85 (2000), 0.81 (2001), 0.84(2002), and 0.89 (2006), respectively. Air quality is shown to be an important factor in the spatial variation of UEQ. Based on the quantifiable fine resolution satellite image parameters, UEQ can promote the understanding of the complex and dynamic factors controlling urban environment.

  • PDF

Clinical Outcomes and Complications after Pedicle Subtraction Osteotomy for Fixed Sagittal Imbalance Patients : A Long-Term Follow-Up Data

  • Hyun, Seung-Jae;Rhim, Seung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.95-101
    • /
    • 2010
  • Objective : Clinical, radiographic, and outcomes assessments, focusing on complications, were performed in patients who underwent pedicle subtraction osteotomy (PSO) to assess correction effectiveness, fusion stability, procedural safety, neurological outcomes, complication rates, and overall patient outcomes. Methods : We analyzed data obtained from 13 consecutive PSO-treated patients presenting with fixed sagittal imbalances from 1999 to 2006. A single spine surgeon performed all operations. The median follow-up period was 73 months (range 41-114 months). Events during peri operative course and complications were closely monitored and carefully reviewed. Radiographs were obtained and measurements were done before surgery, immediately after surgery, and at the most recent follow-up examinations. Clinical outcomes were assessed using the Oswestry Disability Index and subjective satisfaction evaluation. Results : Following surgery, lumbar lordosis increased from $-14.1^{\circ}{\pm}20.5^{\circ}$ to $-46.3^{\circ}{\pm}12.8^{\circ}$ (p<0.0001). and the C7 plumb line improved from $115{\pm}43\;mm$ to $32{\pm}38\;mm$ (p<0.0001). There were 16 surgery-related complications in 8 patients; 3 intraoperative, 3 perioperative, and 10 late-onset postoperative. The prevalence of proximal junctional kyphosis (PJK) was 23% (3 of 13 patients). However, clinical outcomes were not adversely affected by PJK. Intraoperative blood loss averaged 2,984 mL. The C7 plumb line values and postoperative complications were closely correlated with clinical results. Conclusion : Intraoperative or postoperative complications are relatively common following PSO. Most late-onset complications in PSO patients were related to PJK and instrumentation failure. Correcting the C7 plumb line value with minimal operative complications seemed to lead to better clinical results.

Potential of polylactic-co-glycolic acid (PLGA) for delivery Jembrana disease DNA vaccine Model (pEGFP-C1-tat)

  • Unsunnidhal, Lalu;Wasito, Raden;Setyawan, Erif Maha Nugraha;Warsani, Ziana;Kusumawati, Asmarani
    • Journal of Veterinary Science
    • /
    • v.22 no.6
    • /
    • pp.76.1-76.15
    • /
    • 2021
  • Background: The development of a vaccine for Jembrana disease is needed to prevent losses in Indonesia's Bali cattle industry. A DNA vaccine model (pEGFP-C1-tat) that requires a functional delivery system will be developed. Polylactic-co-glycolic acid (PLGA) may have potential as a delivery system for the vaccine model. Objectives: This study aims to evaluate the in vitro potential of PLGA as a delivery system for pEGFP-C1-tat. Methods: Consensus and codon optimization for the tat gene was completed using a bioinformatic method, and the product was inserted into a pEGFP-C1 vector. Cloning of the pEGFP-C1-tat was successfully performed, and polymerase chain reaction (PCR) and restriction analysis confirmed DNA isolation. PLGA-pEGFP-C1-tat solutions were prepared for encapsulated formulation testing, physicochemical characterization, stability testing with DNase I, and cytotoxicity testing. The PLGA-pEGFP-C1-tat solutions were transfected in HeLa cells, and gene expression was observed by fluorescent microscopy and real-time PCR. Results: The successful acquisition of transformant bacteria was confirmed by PCR. The PLGA:DNA:polyvinyl alcohol ratio formulation with optimal encapsulation was 4%:0.5%:2%, physicochemical characterization of PLGA revealed a polydispersity index value of 0.246, a particle size of 925 nm, and a zeta potential value of -2.31 mV. PLGA succeeded in protecting pEGFP-C1-tat from enzymatic degradation, and the percentage viability from the cytotoxicity test of PLGA-pEGFP-C1-tat was 98.03%. The PLGA-pEGFP-C1-tat demonstrated luminescence of the EGFP-tat fusion protein and mRNA transcription was detected. Conclusions: PLGA has good potential as a delivery system for pEGFP-C1-tat.

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

Intraoperative Cerebrospinal Fluid Leak in Extradural Spinal Tumor Surgery

  • Ropper, Alexander E.;Huang, Kevin T.;Ho, Allen L.;Wong, Judith M.;Nalbach, Stephen V.;Chi, John H.
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.338-347
    • /
    • 2018
  • Objective: Patients with extradural spine tumors are at an increased risk for intraoperative cerebrospinal fluid (CSF) leaks and postoperative wound dehiscence due to radiotherapy and other comorbidities related to systemic cancer treatment. In this case series, we discuss our experience with the management of intraoperative durotomies and wound closure strategies for this complex surgical patient population. Methods: We reviewed our recent single-center experience with spine surgery for primarily extradural tumors, with attention to intraoperative durotomy occurrence and postoperative wound-related complications. Results: A total of 105 patients underwent tumor resection and spinal reconstruction with instrumented fusion for a multitude of pathologies. Twelve of the 105 patients (11.4%) reviewed had intraoperative durotomies. Of these, 3 underwent reoperation for a delayed complication, including 1 epidural hematoma, 1 retained drain, and 1 wound infection. Of the 93 uncomplicated index operations, there were a total of 9 reoperations: 2 for epidural hematoma, 3 for wound infection, 2 for wound dehiscence, and 2 for recurrent primary disease. One patient was readmitted for a delayed spinal fluid leak. The average length of stay for patients with and without intraoperative durotomy was 7.3 and 5.9 days, respectively, with a nonsignificant trend for an increased length of stay in the durotomy cases (p=0.098). Conclusion: Surgery for extradural tumor resections can be complicated by CSF leaks due to the proximity of the tumor to the dura. When encountered, a variety of strategies may be employed to minimize subsequent morbidity.

Optimal Pre-Plating Method of Chicken Satellite Cells for Cultured Meat Production

  • Kim, So-Hee;Kim, Chan-Jin;Lee, Eun-Yeong;Son, Yu-Min;Hwang, Young-Hwa;Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.42 no.6
    • /
    • pp.942-952
    • /
    • 2022
  • To establish a pre-plating method of chicken satellite cells with high purity, pre-plating was performed under culture conditions of 37℃ and 41℃, and the pre-plating time was set from a total of 3 hours to 6 hours in consideration of the cell attachment time. The purity of the cells was confirmed by staining paired box protein 7 (Pax7) after proliferation, and Pax7 expression was the highest in culture flasks shaken for 2 hours after incubation at 41℃ for 2 hours to prevent the attachment of satellite cells (p<0.05). Also, when pre-plating and proliferation were performed at 37℃ and 41℃, the Pax7 expression rate was higher at 41℃. The differentiation capabilities of the three groups (T3, T6, and T7) with high Pax7 expression were compared and the fusion index (%) and myotube formation area (%) determined by myosin heavy chain (MHC) staining was calculated. The T6 and T7 groups, which were cultured at 41℃, showed significantly higher values than the T3 group (p<0.05). There was no significant difference in the expression of Pax7 and MHC between the T6 and T7 groups (p>0.05). These results suggest that pre-plating at 41℃ for a total of 4 hours was the most efficient in terms of cost and time for purifying chicken satellite cells for cultured meat.

Culturing characteristics of Hanwoo myosatellite cells and C2C12 cells incubated at 37℃ and 39℃ for cultured meat

  • Sehyuk Oh;Sanghun Park;Yunhwan Park;Yun-a Kim;Gyutae Park;Xiangshun Cui;Kwansuk Kim;Seontea Joo;Sunjin Hur;Gapdon Kim;Jungseok Choi
    • Journal of Animal Science and Technology
    • /
    • v.65 no.3
    • /
    • pp.664-678
    • /
    • 2023
  • To improve culture efficiency of Hanwoo myosatellite cells, these cells were cultured at different temperatures. Hanwoo myosatellite cells were compared with C2C12 cells to observe proliferation and differentiation at culture temperatures of 37℃ and 39℃ and determine the possibility of using them as cultured meat. Immunofluorescence staining using Pax7 and Hoechst, both cells cultured at 37℃ proliferated better than cultured at 39℃ (p < 0.05). When differentiated cells were stained with myosin and Hoechst, there was no significant difference in myotube thickness and Fusion index (p > 0.05). In Western blotting analysis, Hanwoo myosatellite cells were no significant difference in the expression of myosin between cells differentiated at the two temperatures (p > 0.05). C2C12 cells were no significant difference in the expression of myosin between cells differentiated at the two temperatures (p > 0.05). In reverse transcription and quantitative polymerase chain reaction (RT-qPCR) analysis, Hanwoo myosatellite cells cultured at 39℃ had significantly (p < 0.05) higher expression levels of MyHC, MYF6, and MB than those cultured at 37℃. C2C12 cells cultured at 39℃ showed significantly (p < 0.05) higher expression levels of MYOG and MB than those cultured at 37℃. To increase culture efficiency of Hanwoo myosatellite cells, proliferating at 37℃ and differentiating at 39℃ are appropriate. Since results of temperature differences of Hanwoo myosatellite cells were similar to those of C2C12 cells, they could be used as a reference for producing cultured meat using Hanwoo satellite cells.

A Comparative Study on the Adipogenic and Myogenic Capacity of Muscle Satellite Cells, and Meat Quality Characteristics between Hanwoo and Vietnamese Yellow Steers

  • Nguyen Thu Uyen;Dao Van Cuong;Pham Dieu Thuy;Luu Hong Son;Nguyen Thi Ngan;Nguyen Hung Quang;Nguyen Duc Tuan;In-ho Hwang
    • Food Science of Animal Resources
    • /
    • v.43 no.4
    • /
    • pp.563-579
    • /
    • 2023
  • Myogenesis and adipogenesis are the important processes determining the muscle growth and fat accumulation livestock, which ultimately affecting their meat quality. Hanwoo is a popular breed and its meat has been exported to other countries. The objective of this study was to compare the myogenesis and adipogenesis properties in satellite cells, and meat quality between Hanwoo and Vietnamese yellow cattle (VYC). Same 28-months old Hanwoo (body weight: 728±45 kg) and VYC (body weight: 285±36 kg) steers (n=10 per breed) were used. Immediately after slaughter, tissue samples were collected from longissimus lumborum (LL) muscles for satellite cells isolation and assays. After 24 h post-mortem, LL muscles from left carcass sides were collected for meat quality analysis. Under the same in vitro culture condition, the proliferation rate was higher in Hanwoo compared to VYC (p<0.05). Fusion index was almost 3 times greater in Hanwoo (42.17%), compared with VYC (14.93%; p<0.05). The expressions of myogenesis (myogenic factor 5, myogenic differentiation 1, myogenin, and myogenic factor 6)- and adipogenesis (peroxisome proliferator-activated receptor gamma)-regulating genes, and triglyceride content were higher in Hanwoo, compared with VYC (p<0.05). Hanwoo beef had a higher intramuscular fat and total monounsaturated fatty acids contents than VYC beef (p<0.05). Whilst, VYC meat had a higher CIE a* and total polyunsaturated fatty acids content (p<0.05). Overall, there was a significant difference in the in vitro culture characteristics and genes expression of satellite cells, and meat quality between the Hanwoo and VYC.