• Title/Summary/Keyword: furnace

Search Result 3,794, Processing Time 0.034 seconds

Combustion Charateristics of Biomass Blends on a 15KW Pulverized Coal furnaces (15kW급 미분탄 연소로내에서 바이오매스 혼소율 변화에 따른 연소 특성 비교)

  • Lee, Sangmin;Sung, Yonmo;Choi, Minsung;Moon, Cheoreon;Choi, Gyungmin;Kim, Duckjool
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.41-44
    • /
    • 2014
  • This study focused on the effect of the biomass blended ratio on air-staged pulverized coal furnace. The hybrid NOx reduction technology between fuel blending and air staging has been applied in an air-staged pulverized coal fired furnace. The results indicated that co-firing biomass with coal could reduce NOx emissions in an air-staged combustion. In addition, carbon burnout and flame temperature increased under the air-staged condition. A dominant synergistic effect on NOx reduction and carbon burnout was observed when biomass co-firing with coal was applied in air staged combustion.

  • PDF

Sn과 SnO 박막을 이용한 SnxSy 박막 합성

  • Kim, Tae-Hun;Kim, Jeong-Ju;Lee, Jun-Hyeong;Heo, Yeong-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.266.1-266.1
    • /
    • 2016
  • 최근 태양전지에 대한 연구가 활발하기 이루어지고 있다. 그 중 본 연구에선 태양전지에 사용될 광흡수층에 대한 연구로 광흡수층은 광흡수계수와 밴드갭의 영향을 받고 SnS가 적합한 특성을 지니고 있다고 판단하여 이에 대한 합성과 특성에 대한 연구를 진행 하였다. SnxSy 박막은 Electrochemical deposition, Spray pyrolysis deposition, Furnace를 이용하는 등 다양한 방법이 있다. 이러한 방법들은 대부분 막질이 좋지 않다고 알려져 있는데 그 중 Furnace를 이용하는 방법은 간단하며 넓은 면적에 쉽게 증착이 가능하다는 장점이 있지만 S의 양과 온도에 민감하다. 본 연구에서는 Sn과 SnO 박막을 전구체로 사용하였으며 S의 양과 온도를 조절하여 로를 이용하여 합성하였다. 이에 대한 조성 및 구조적 특성을 분석하기 위해 XRD를 전기적 특성을 확인하기 위하여 Hall effect measurement를 통하여 측정하였다.

  • PDF

Experimental Study for Oxygen Methane MILD Combustion in a Laboratory Scale Furnace (Laboratory Scale 연소로를 적용한 산소 메탄 MILD 연소에 대한 실험적 연구)

  • Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.4
    • /
    • pp.6-15
    • /
    • 2016
  • The oxygen fuel MILD (Moderate or Intense Low-oxygen Dilution) combustion has been considered as one of the promising combustion technology for flame stability, high thermal efficiency, low emissions and improved productivity. In this paper, the effect of oxygen and fuel injection condition on formation of MILD combustion was analyzed using lab scale oxygen fuel MILD combustion furnace. The results show that the flame mode was changed from a diffusion flame mode to a split flame mode via a MILD combustion flame mode with increasing the oxygen flow rate. A high degree of temperature uniformity was achieved using optimized combination of fuel and oxygen injection configuration without the need for external oxygen preheating. In particular, the MILD combustion flame was found to be very stable and constant flame temperature region at 7 KW heating rate and oxygen flow rate 75-80 l/min.

A Study on Freezing and Trawing Resistance of Concrete with the Ratio of Ground Granulated Blast-Furnace Slag Replacement (고로슬로그 미분말의 치환율에 따른 콘크리트의 동결융해 저항성에 관한 연구)

  • 최세규;김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.149-155
    • /
    • 1997
  • 고로슬래그 미분말을 사용한 콘크리트\ulcorner 수화속도가 느려 어린 재령시 동해의 영향을받기 쉽다. 본 연구에서는 고로슬래그 미분말을 사용한 콘크리트의 동결융해 저항성을 알아보기 위해 고로슬래그 미분말의 치환율과 물-결합재비를 변화시켜 제조한 콘크리트에 대해 동결융해시험을 실시하였다. 또한 동일한 치환율, 물-결합재비의 콘크리트에 AE제를 첨가시켜 동결융해 저항성의 개선효과를 알아보았다. 시험결과 고로슬래그 미분말의 치환율이 증가할수록 동결융해 저항성은 작게 나왔다. 또한 non-AE 콘크리트의 경우 물-결합재비가 51%, 45%일 때 내구성지수는 각각 2.4%, 40.0%이하로 매우 나쁘게 나타났으나, AE콘크리트의 경우 물 -결합재비가 45%와 51%인 콘크리트의 내구성지수는 각각 90.2% 80.9%이상으로 동결융해 저항성이 매우 우수하게 나타났다.

A Study on the Mix Proportion of Self-Compacting High Performance Concrete (자기충전성 고성능 콘크리트의 배합에 관한 연구)

  • 이승한;한형섭;이원기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.269-274
    • /
    • 1998
  • In this study, to increase fluidity and resistance of segregation of materials, the effect of each of the materials, which have effects on high performance concrete from investigating the properties of strength and drying shrinkage of high performance concrete made by the basic mix proportion used fly-ash and ground granulated blast-furnace slag after hardening, has been checked. According to the experimental results, fluidity on W/C = 34% was satisfied within slump-flow 65$\pm$ 5cm and U-type self-compactability difference 5cm. On the properties of strength, high performance concrete produced compressive strength over 400kg/$\textrm{cm}^2$ in 28days when powder was replaced by 40% of fly-ash and 60% of ground granulated blast-furnace slag. And compressive strength was taken over 600kg/$\textrm{cm}^2$ equal to non-replacement in 91days. Also, the length change of concrete with the addition of fly-ash was smaller than that without it. Therefore, it may be effective on the decrease of drying shrinkage volume.

  • PDF

A Fundamental Study on the Converter Slag Coarse Aggregate Used in Concrete (전로슬래그 굵은골재를 콘크리트용으로 사용하기 위한 기초적 연구)

  • 문한영;유정훈;정호섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.233-236
    • /
    • 1999
  • In this paper, we carried out fundamental experiments to use the steel manufacturing slag as a concrete aggregate. Generally there are two types of slag, the blast-furnace slag and the steel manufacturing slag. The latter is classified by the difference of manufacturing method of steel into the convertor slag and the electric-furnace slag. The steel manufacturing slag mainly contains SiO2 and CaO as the chmical composition. The reaction with water and a little of free CaO in the steel manufacturing slag makes the expansion of volume change. Therefore, we primarily investigated physical properties, expansion mechanism, pH value, aging effects and aging methods in the steel manufacturing slag. Then compressive strength of concrete with steel slag aggregate is measured.

  • PDF

Effect of Blast-Furnace Slag Powder on the Mechanical Properties of Hardened Concrete (고로슬래그 미분말을 사용한 콘크리트의 역학적 특성에 관한 연구)

  • 김형래;최진만;임정수;김상규;변승호;윤철현;최현국
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.207-210
    • /
    • 1999
  • This experimental study was carried out to estimate the effects of mixing dosage rate and blaine on the mechanical properties of concrete admixed with ground granulated blast-furnace slag (BFS) powder. According to the test results, compressive strength of concrete admixed with slag not more than 35% was at least 80% of compressive strength of OPC concrete at 3 days age, and much bigger than that of OPC concrete at 28 days age. Consequently, in order to apply the BFS to the concrete is demanded, and rigorous construction management should be followed.

  • PDF

Strength Development of Concrete Using Blast-Furnace Slag Cement under Various Curing Temperatures (양생온도변화에 따른 고로슬래그 시멘트를 사용한 콘크리트의 강도증진 성상)

  • 윤기원;유호범;한민철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.163-166
    • /
    • 1999
  • In this paper, strength development of concrete using blast-furnace slag cement(BSC) and ordinary portland cement(OPC) are discussed under varius W/C and curing temperatures. According to the experimental results, strength development of BSC concrete is lower than that of OPC concrete in low temperature at early age and maturity. In high curing temperature, BSC concrete has higher strength development than that of low temperature regardless of the elapse of age and maturity. BSC has much effect on the strength development of concrete at the condition of mass concrete, hot weather concreting and the concrete products with the steam curing, which is influenced by high temperature.

  • PDF

Development of High Strength Blast Furnace Slag Cement at Early Ages. (초기 고강도 고로슬래그 시멘트의 개발)

  • 황인태;김태식;박응모;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.823-828
    • /
    • 1999
  • Blast furnace slag cement(BSC) has many merits in relation to its prodution cost or environmental problem of these days, but it has still some limitation in broad use mainly because it has the lower early hydration strength than the normal portland cement(PC) has. In the present study, several different experimental concepts to improve its low strength in the early hydration stage were tried out which addition of the effective alkali activators such as Ca(OH)2 and limestone powder, fly ash in existing BSC. It was found that the addition of suitable quantity the effective alkali activators such as Ca(OH)2 and limestone powder, fly ash in BSC can be a possible way to get enough early strength compared with the PC and existing BSC.

  • PDF

Properties of Fresh Concrete admixed with Blast-Furnace Slag Powder with variations of Blaine and Content (분말도 및 치환율 변화에 따른 고로슬래그 미분말 혼입 콘크리트의 초기물성)

  • 최진만;김형래;임정수;김상규;이도현;변승호;윤철현;최현국
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.297-300
    • /
    • 1999
  • This study was carried out to present the properties of fresh concrete made with ground granulated blast-furnace slag (BFS) powder with variations of blaine and content, and to estimate the utilization of the BFS concrete as admixtural materials for concrete structures of the building. According to the results, the fluidity of concrete which BFS dosage rate was 45% had the considerable difference from that of concrete which BFS dosage rate was not bigger than 35%. Also, the diminution of bleeding was appeared with the increase of blaine and content of BFS. It is concluded that BFS concrete of low blaine can be used effectively in concrete structures of the building.

  • PDF