• Title/Summary/Keyword: functional transfer

Search Result 564, Processing Time 0.025 seconds

Classification of Multi-modal Transfer Center Considering the Regional and Functional Characteristics (지역 및 기능적 특성을 고려한 복합환승시설 유형분류)

  • Kim, Tae-Gyun;Lee, Sam-Su;Byun, Wan-Hee
    • Land and Housing Review
    • /
    • v.4 no.1
    • /
    • pp.89-98
    • /
    • 2013
  • In recent years, it was recognized that aurban policy paradigm of sustainable urban growth management and transportation policies have been shifted : from the era of automobile-oriented policy to the era of public transport policy. Against this backdrop, the introduction of the multi-modal transfer center is very consequential. Therefore, it is necessary for the introduction of wide-area and local-centric transfer facilities, as well as the center of the country-led national backbone transfer center. This study was applicable at the multi-modal transfer center plans to introduce guidelines to provide transit facilities, considering the regional and functional characteristics to classify the types of multi-modal transfer center. The final types of multi-modal transfer center were classified into six, and by considering the combination of the criteria to be classified. The multi-modal transfer center type classification based on the case analysis of the types of facilities at domestic and abroad. If the data of multi-modal transfer are accumulated continuously, can expect a more reliable type classification.

The appearance change and heat·moisture transfer properties of knitted fabric by yarn shrinkage (원사의 수축에 따른 다공성 편성물의 형태변화와 열·수분 전달특성)

  • Sang, Jeong-Seon;Park, Juhyun;Lee, Mee-Sik;Oh, Kyung Wha
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.6
    • /
    • pp.880-892
    • /
    • 2017
  • In this study, the appearance change and the heat moisture transfer properties of knitted fabric by yarn shrinkage were examined to obtain useful data on the development of thermo-sensitive functional materials. Eleven types of knitted fabric were knitted using highly bulky acrylic-blended yarn. After shrinking the specimens using dry heat treatment, the appearance change and thickness were measured. An HEC simulator was adopted for measuring the heat moisture transfer properties of specimens by yarn shrinkage. When holes were arranged vertically in the mesh structure, the specimens with 2,500 and 5,000 holes showed high percent change of hole area, appearance, and thickness. When holes were diagonally arranged in the mesh structure, the percent change of hole area in the specimen with 1,250 holes was larger than the one with 2,500 holes. However, the dimensional stability of the specimen with 2,500 holes was better because of its smaller appearance and thickness change. In the tuck structure, the percent change of hole area in the specimen with 625 and 416 holes was relatively large compared with the appearance and thickness change. Furthermore, the hole size in the tuck structure was smaller than that in the mesh structure but the percent change of hole area was larger. Therefore, it was proved that the tuck structure is more suitable than the mesh structure for developing thermo-sensitive functional materials. Heat moisture transfer property test verified that the change of hole area by yarn shrinkage enabled obtaining the thermal effect due to the distinct temperature difference in the inner layer.

Latissimus Dorsi Transfer in Brachial Plexus Injury for the Elbow Flexion (상완 신경총 손상후 주관절 근력 회복을 위한 광배근 전이술)

  • Han, Chung-Soo;Chung, Duke-Whan;Soh, Jae-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1998
  • The incidence of brachial plexus injury is increasing because of the development of motor vehicle but the the results of treatment was reported poor due to its complex anatomical structure and changes of function and sensory during the recovery after trauma. But the results of treatment has been improved by the recently introduced high sensitive diagnostic method that can evaluate accurately the site and extent of the injury and treatment method. Restoration of the elbow flexion is the most important goal of treatment after brachial plexus injury and nerve graft, neurotization and muscle transfer were used for methods of treatment. From December 1992 to May 1994, the author performed 6 cases of latissimus dorsi transfer at the same side for the improvement of elbow flexion in the patients of brachial plexus injury. There were 5 cases of male, one case of female and average age was 22 years old. The causes of injury were traffic accident in 3 cases, gun shot injury, falldown and birth injury in each one case and in all cases, the type of injury were upper arm type. The average follow up period were 1 year 5 months ranging from 12 months to 4 years 5 months. In all cases, active elbow flexion was impossible before operation and average muscle power was grade I. We analysed the active range of motion, muscle power and the functional results. At the last follow up, range of active elbow flexion was average $124^{\circ}$ and flexion contracture was average 11 degrees and the average of muscle power was grade IV. In the functional analysis, there were two cases of excellent, three cases of good and 1 case of fair. There was no complications including wound infection, vascular compromise and donor site problem. The results of latissimus dorsi transfer for improvement elbow flexion in the patients of brachial plexus injury is one of the useful mettled for the restoration of elbow flexion.

  • PDF

Photoaddition Reactions of Silyl Ketene Acetals with Aromatic Carbonyl Compounds: A New Procedure for β-Hydroxyester Synthesis

  • Yoon, Ung-Chan;Kim, Moon-Jung;Moon, Jae-Joon;Oh, Sun-Wha;Kim, Hyun-Jin;Mariano, Patrick S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.9
    • /
    • pp.1218-1242
    • /
    • 2002
  • Photochemical reactions of aromatic carbonyl compounds with silyl ketene acetals have been explored. Irradiation of acetonitrile or benzene solutions containing aryl aldehydes or ketones in the presence of silyl ketene acetals is observed to promo te formation of ${\beta}-hydroxyester$, 2,2-dioxyoxetane and 3,3-dioxyoxetane products. The ratios of these photoproducts, which arise by competitive single electron transfer (SET) and classical Paterno-Buchi mechanistic pathways, is found to be dependent on the degree of methyl-substitution on the vinyl moieties of the ketene acetals in a manner which reflects expected alkyl substituent effects on the oxidation potentials of these electron rich donors. An analysis of the product distribution arising by irradiation of a solution containing butyrophenone (6) and the silyl ketene acetal 9, derived from methyl isobutyrate, provides an estimate of the rate constants for the competitive Norrish type Ⅱ, SET and Paterno-Buchi processes occuring. Finally, sequences involving silyl ketene acetal-aryl aldehyde or ketone photoaddition followed by 2,2-dioxyoxetane hydrolysis represent useful procedures for Claisen-condensation type, ${\beta}-hydroxyester$ synthesis.

Novel Naphthalene Based Lariat-Type Crown Ethers Using Direct Single Electron Transfer Photochemical Strategy

  • Park, Hea Jung;Sung, Nam Kyung;Kim, Su Rhan;Ahn, So Hyun;Yoon, Ung Chan;Cho, Dae Won;Mariano, Patrick S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3681-3689
    • /
    • 2013
  • This study explored a direct SET-photochemical strategy to construct a new family of thioene conjugated-naphthalamide fluorophore based lariat-crown ethers which show strong binding properties towards heavy metal ions. Irradiations of designed nitrogen branched (trimethylsilyl)methylthio-terminated polyethylenoxy-tethered naphthalimides in acidic methanol solutions have led to highly efficient photocyclization reactions to generate naphthalamide based lariat type thiadiazacrown ethers directly in chemo- and regio-selective manners which undergo very facile secondary dehydration reactions during separation processes to produce their corresponding amidoenethio ether cyclic products tethered with electron donating diethyleneoxy- and diethyenethio-side arm chains. Fluorescence and metal cation binding properties of the lariat type enamidothio products were examined. The photocyclized amidoenethio products, thioene conjugated naphthalamide fluorophore containing lariat-thiadiazacrowns exhibited strong fluorescence emissions in region of 330-450 nm along with intramolecular exciplex emissions in region of 450-560 nm with their maxima at 508 nm. Divalent cation $Hg^{2+}$ and $Pb^{2+}$ showed strong binding to sulfur atom(s) in side arm chain and atoms in enethiadiazacrown ether rings which led to significant enhancement of fluorescence from its chromophore singlet excited state and concomitant quenching of exciplex emission. The dual fluorescence emission responses towards divalent cations might provide a new guide for design and development of fluorescence sensors for detecting those metals.

A Review on Transfer Process of Two-dimensional Materials

  • Kim, Chan;Yoon, Min-Ah;Jang, Bongkyun;Kim, Jae-Hyun;Kim, Kwang-Seop
    • Tribology and Lubricants
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • Large-area two-dimensional (2D) materials synthesized by chemical vapor deposition on donor substrates are promising functional materials for conductors, semiconductors, and insulators in flexible and transparent devices. In most cases, 2D materials should be transferred from a donor substrate to a target substrate; however, 2D materials are prone to damage during the transfer process. The damages to 2D materials during transfer are caused by contamination, tearing, and chemical doping. For the commercialization of 2D materials, a damage-free, large-area, and productive transfer process is needed. However, a transfer process that meets all three requirements has yet to be developed. In this paper, we review the recent progress in the development of transfer processes for 2D materials, and discuss the principles, advantages, and limitations of each process. The future prospects of transfer processes are also discussed. To simplify the discussion, the transfer processes are classified into four categories: wet transfer, dry transfer, mechanical transfer, and electro-chemical transfer. Finally, the "roll-to-roll" and "roll-to-plate" dry transfer process is proposed as the most promising method for the commercialization of 2D materials. Moreover, for successful dry transfer of 2D materials, it is necessary to clearly understand the adhesion properties, viscoelastic behaviors, and mechanical deformation of the transfer film used as a medium in the transfer process.

Reconstruction of the Shoulder using Rotational Latissimus Dorsi Flap in the Malignant Fibrous Histiocytoma (악성 섬유성 조직구종에서 광배근피판을 이용한 견관절 재건술)

  • Han, Chung-Soo;Chung, Duke-Whan;Lee, Young-Ho;Im, Yang-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • Introduction : The Functional muscle transfer is used to reconstruct the injuried muscle and paralysis of the shoulder. Especially transfer of the trapezius has been the treatment of choice but it has disadvantages of inadequate function and deformed contour, and instability of humeral head in case of acromion resection. We report an operation for shoulder reconstruction after wide resection of malignant fibrous histiocytoma, using rotational latissimus dorsi flap and review the operation method and clinical outcome. Materials and Methods : A patient, 53 year old, with malignant fibrous histiocytoma in the acromioclavicular joint area had been underwent wide excision, including the deltoid, clavicular head of pectoralis major, part of trapezius, lateral 1/3 of clavicle and acromion including scapular spine. The rotational latissimus dorsi flap with its neurovascular pedicle was dissected and then placed over the resected area and transfer of muscle attached at coracoid process was done to achieve stability of the humeral head. The range of motion of the shoulder and test of muscle power were evaluated for functional outcome. Total follow-up period is 2 years 11 months. Results : At last follow-up, the range of motion of the shoulder is abduction $90^{\circ}$, flexion $90^{\circ}$, internal rotation $40^{\circ}$, external rotation $50^{\circ}$ and the muscle power is 4 grade in all direction and then we obtained good functional results. There are no complications such as instability or subluxation of the humeral head and deformed contour and he is a disease-free survival state. Conclusions : The transfered latissimus dorsi flap provides adequate lever arm and stabilization and covering of the humeral head by sufficient muscle volume and width. This procedure can be useful not only for the paralysed deltoid reconstruction but also for use in reconstructive surgery after wide resection of the shoulder for malignant tumor.

  • PDF

An Algorithm to Guide Recipient Vessel Selection in Cases of Free Functional Muscle Transfer for Facial Reanimation

  • Henry, Francis P.;Leckenby, Jonathan I.;Butler, Daniel P.;Grobbelaar, Adriaan O.
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.716-721
    • /
    • 2014
  • Background The aim of this study was to review the recipient vessels used in our cases of facial reanimation with free functional muscle transfer and to identify patient variables that may predict when the facial vessels are absent. From this we present a protocol for vessel selection in cases when the facial artery and/or vein are absent. Methods Patients were identified from November 2006 to October 2013. Data was collected on patient demographics, facial palsy aetiology, history of previous facial surgery/trauma and flap/recipient vessels used. A standard operative approach was adopted and performed by a single surgeon. Results Eighty-seven eligible patients were identified for inclusion amongst which 98 hemifaces were operated upon. The facial artery and vein were the most commonly used recipient vessels (90% and 83% of patients, respectively). Commonly used alternative vessels were the transverse facial vein and superficial temporal artery. Those with congenital facial palsy were significantly more likely to lack a suitable facial vein (P=0.03) and those with a history of previous facial surgery or trauma were significantly more likely to have an absent facial artery and vein (P<0.05). Conclusions Our algorithm can help to guide vessel selection cases of facial reanimation with free functional muscle transfer. Amongst patients with congenital facial palsy or in those with a previous history of facial surgery or trauma, the facial vessels are more likely to be absent and so the surgeon should then look towards the transverse facial vein and superficial temporal artery as alternative recipient structures.

Nanofilm Transfer Methods and Interfacial Fracture Mechanics (나노박막 전사 방법 및 계면 파괴 역학)

  • Kang, Sumin;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.9-19
    • /
    • 2020
  • Transferring of functional nanofilms onto target substrates is a cornerstone to developing nanofilm-based nextgeneration applications. In this work, we provide a brief review of recent advances on nanofilm transfer methods by categorizing them into the following three methods: wet-etching transfer, electrochemical delamination, and mechanical transfer. Furthermore, the mechanical transfer method, which is regarded as a promising technology owing to its facile, substrate recyclable, and widely applicable process, is overviewed by focusing on fracture mechanics approaches. Finally, the perspectives and challenges for future development of the mechanical transfer method are discussed.

Immediate Toe-to-Hand Transfer in Acute Hand Injuries (급성 수부 손상시 즉시 족지 전이술)

  • Woo, Sang-Hyun;Kim, Hak-Soo
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.1
    • /
    • pp.19-28
    • /
    • 2002
  • From 1994-2001, 25 mutilated digits were reconstructed with immediate toe-to-hand transfer in acute hand injury in 21 patients. There were 15 cases of great toe-to-hand transfer(partial great toe transfer 8 cases, modified wrap-around procedure 2 cases, and trimmed great toe transfer 2 cases) for thumb reconstruction, 2 cases of second toe transfer for index reconstruction, and 4 cases of simultaneous two toe-to-hand transfer(great toe & second toe transfer 1 case, bilateral second-toe transfer 2 cases, combined second & third toe transfer 1 case) for reconstruction of multiple digit amputations. Two cases of emergency exploration(2/25, 8%) were successfully salvaged. The incidence of emergency exploration and postoperative infection was not significantly different from that of the elective toe-to-hand transfer cases. Duration of industrial insurance coverage was 225 days, which is much shorter than that of elective cases. Among 43% of patients maintained their original job even after injury and immediate toe-to-hand transfer. The subjective satisfaction self- assessment scores of aesthetic appearance and function on the new reconstructed thumb were 80 and 88 in average, respectively, over a total score of 100. These were higher than those of reconstruction of other digits, but lower than those of elective reconstruction. The donor site after harvest of the great toe was mostly unsatisfied in a view of appearance. Immediate toe-to-hand transfer provides many advantages over elective procedure in acute hand injuries such as single stage reconstruction, shortened convalescent period, early return to work and efficient socio-economic factor. Furthermore because there were no significant differences in success rate, frequency of complications or ultimate functional result, immediate toe-to-hand transfer is a safe and reliable procedure in case of limited indications for acute digits loss.

  • PDF