• Title/Summary/Keyword: functional occlusal rehabilitation

Search Result 82, Processing Time 0.024 seconds

Maxillary complete denture with posterior zirconia occlusion and mandibular implant support fixed prostheses in completely edentulous patients with orofacial dystonia (구강안면 근긴장이상을 가진 완전 무치악 환자에서 구치부 지르코니아 교합면을 갖는 상악 총의치와 하악 임플란트 지지 고정성 보철물의 수복)

  • Jong-Min Seo;Chang-Mo Jeong;So-Hyoun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.237-249
    • /
    • 2023
  • Orofacial dystonia is a neuromotor disorder that causes irregular or repetitive movements of the face, lips, tongue, and jaw involuntarily, also called tic disorder. Edentulous patients with these symptoms experience functional and aesthetic problems, including difficulty using complete dentures, speech and swallowing difficulties, and orofacial pain. In this case, for a patient with orofacial dystonia who experienced complete edentulism at a relatively young age, restorative treatment was performed with a maxillary complete denture with bilateral posterior zirconia occlusal surfaces and a mandibular implant-supported fixed prosthesis, and continuous smile training was performed. The aim was to improve the aesthetics of facial muscles. As a result of the treatment, the patient was very satisfied with not only improved chewing function and aesthetics, but also regained psychological stability and was able to lead a normal daily life, so we would like to report this.

A Case Report of Maxillary Complete Edentulous Patient with a Class III Jaw Relations (III급 악골 관계를 가진 상악 편악 무치악 환자의 수복)

  • Park, Mi-hee;Hong, Jun-won;Choi, Jee-ha;Lee, Jung-jun;Park, Ju-mi;Song, Kwang-yeob;Ahn, Seung-geun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.431-436
    • /
    • 2009
  • In a case of class III skeletal patients with severe alveolar bone resorption, it must be a complete denture treatment plan provided stable and durable occlusion. Despite a markedly increased tooth mobility and unfavorable crown-to-root ration due to periodontal tissue breakdown, if the inflammatory process is controlled and an adequate oral hygiene performed, fixed splints will be considered. Patient's discomfort will be eliminated by achievement better clinical tooth mobility using fixed splints. So it can be a cost and time effective treatment option. In this case, it used a T-Scan System for confirmation a bilateral balanced occlusion and a occlusal force distribution reflected a patient's functional mandibular movement.

Oral rehabilitation of edentulous patient with mandibular implant overdenture using surgical guide (서지컬 가이드를 이용한 하악 임플란트 피개의치 수복 증례)

  • Lee, Dong Hwan;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.339-346
    • /
    • 2022
  • Compared with traditional full dentures, mandibular implant overdentures have the advantage in that good support and retention can be obtained even with two implants. When manufacturing a mandibular implant overdenture using two implants, it is important to place the implant in the correct position. The long-term prognosis of overdenture is good when two implants are placed in the direction vertical to the occlusal plane and parallel to each other at the canine position. However, it is difficult to place two implants in the correct position in edentulous patients, and if you use surgical guides in these cases, you can get help in placing the implants in a prosthetically advantageous position. This case, a 57-year-old male patient, came to our hospital with all upper and lower teeth removed due to periodontal disease. Therefore, the maxilla was restored with a traditional full denture and the mandible was restored with an implant overdenture using two implants, which resulted in satisfactory functional and esthetic results.

Fixed implant rehabilitation of maxillary edentulous patient using intraoral scanning digital workflow: a case report (상악 완전 무치악 환자에서 구강 스캐닝 디지털 워크플로우를 활용한 완전 고정성 임플란트 수복 증례)

  • Seung Min Park;YoungBum Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.38-46
    • /
    • 2024
  • In order to treat edentulous patients with fixed implant prosthesis, the final prosthesis form should be predetermined based on the anatomic structures of the arch, the opposing dentition, and the occlusal plane. The design and occlusion of the interim prosthesis can provide useful information when fabricating the definitive prosthesis. In this case report, scan data of the edentulous region and the interim prosthesis were superimposed through an intraoral scanning digital workflow. In this way, the interim prosthesis information was incorporated into the design of the final prosthesis. Furthermore, the interim prosthesis data acquired through intraoral scanning was utilized to plan the positions and angles of the implants based on the final prosthesis design. Surgical guides were used to accurately place the implants in the planned three-dimensional positions. In this case report, satisfactory esthetic and functional clinical outcomes were achieved through application of digital techniques.

Prosthetic rehabilitation of partially edentulous patient after hemimandiblectomy: Case report (하악골 부분절제술 시행한 부분 무치악 환자에서 보철 수복 증례)

  • Lee, Dong-Hun;Yoo, Dong-Soo;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.39-45
    • /
    • 2015
  • Loss of continuity of the mandible destroys the balance and symmetry of mandibular function, leading to altered mandibular movements and deviation of the residual fragment towards the resected side. Apart from deviation, other dysfunctions include difficulty in swallowing, speech, mandibular movements, mastication, and respiration are accompanied. In general, surgical reconstruction is considered first then proceeds to the prosthetic restorations. However, patients with systemic disease such as BRONJ (Bisphosphonate related osteonecrosis of the Jaw), surgical reconstruction may be limited. Thus, the prosthetic restoration remains as the only resort. Numerous prosthetic methods are employed to minimize deviation and to improve masticatory efficiency, function and esthetics. If a removable partial denture is the selected treatment modality, maximum stability of the partial denture base may be accomplished with a functional impression procedure by means of eliminating lateral and horizontal forces caused by the functional movements of the lips, cheeks and tongue. Also, Twin occlusion is used to obtain a favorable occlusal relationship and check support for esthetics. The purpose of this case report is to demonstrate how neutral zone impression technique and twin occlusion scheme were applied to restore a hemi-mandiblectomy patient with BRONJ syndrome to achieve satisfactory results in functional and esthetic aspects.

Full Mouth Rehabilitation with a Overlay Denture (피개의치를 이용한 지적장애인의 완전구강회복)

  • Ko, Kyung-Ho;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.385-395
    • /
    • 2012
  • This clinical report presents the case using overlay dentures to treat a patient with cleft lip and palate and malocclusion. This patient requires vigorous treatment such as orthodontic treatment and combined orthodontic/oral surgery procedures. Overlay denture can be used as an alternative treatment option. Intraoral and radiographic examinations were done. The vertical dimension of occlusion was evaluated for proper prosthetic procedures and the surveying in the diagnostic cast was done. Considering the tissue and teeth undercut, the alterations of teeth shape were done. Final preparation and impression was performed. After the evaluation of vertical dimension and occlusion with wax-denture, the dentures were polymerized. Clinical remounting and occlusal adjustment were done on the articulator. Overlay dentures were delivered and the patient was recalled for relining. The overlay dentures satisfied patient's esthetic and functional requirements and provided a stable occlusion. Overlay dentures in this case were a reversible and relatively inexpensive treatment for this patient, however the potential possibilities of caries and periodontal disease as a result of poor oral hygiene should be prevented with periodic recall.

Analysis of functional load on the dentated skull with unilateral molar loss during simulated bilateral clenching clenching (이악물기 치아접촉시 편측 구치 상실을 지닌 두개골의 부하분석)

  • Jeong, SeogJo;Jeong, SeungMi;Kang, DongWan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.245-256
    • /
    • 2001
  • The purpose of this study is to analyze the mechanical stress and displacement on the jaws during the simulated bilateral clenching task on the three-dimensional finite element model of the dentated skull with unilateral molar loss. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 2.0mm intervals. The fully assembled finite element model consists of the articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The FE model was used to simulate the bilateral clenching in intercuspal position. The loading condition was the force of the masseter muscle exerted on the mandible as reported by Korioth et al. degrees of freedom of the zygomatic region where the masseter muscle is attached were fixed as restraints. In order to reflect the actual action of the muscles force, the displacement of the region was attached where the muscle is connected to the temporal bone and restraint conditions were given values identical to values at the attachment region of the masticatory muscle but with the opposite direction of the reaction from when the muscle force is acted on the mandible. Although the mandible generally has higher displacement and von Mises stress than the maxilla, its mandibular corpus on the molar-loss side has a higher stress and displacement than the molar-presence side. Because the displacement and von Mises Stress was the highest on the lateral surface of mandibular corpus with molar loss, the stress level of the condyle on the molar-loss side is greater than that of the molar-presence side, which in turn caused the symphysis of the mandible to bend. In conclusion, the unilateral posterior bite collapse with molar loss under para-functional activities such as bruxism and clenching can affect the stress concentration on the condyle and mandibular corpus. It is therefore necessary to consider the biomechanical function of dento-skeleton under masticatory force while designing the occlusal scheme of restoration on alveolar bone with the posterior collapse.

  • PDF

Complete denture fabrication of a skeletal class III edentulous patient considering anterior neutral zone: a case report (골격성 III급 무치악 환자에서 전치부 중립대를 고려한 총의치 제작 증례)

  • Su-Hun Kim;Hyung-Jun Kim;Sang-Won Park;Hyun-Pil Lim;Chan Park;Woo-hyung Jang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.91-99
    • /
    • 2024
  • In the case of skeletal class III edentulous patients, the stability of dentures can be achieved by using a crossbite by considering the residual ridge relationship when fabricating complete dentures. Forming the anterior teeth in a normal occlusal relationship in a skeletal class III ridge relationship may reduce the stability of the denture by increasing the anterior cantilever. However, when patients use complete dentures, not only functional aspects but also aesthetic aspects are important. The aesthetics of complete dentures depends on how the anterior artificial teeth are arranged, and cases of complete denture fabrication using normal occlusion or edge-to-edge bite in edentulous patients with skeletal class III ridge relationships have been reported. In this case, complete dentures were fabricated for an edentulous patient with a skeletal class III edentulous patients by forming anterior edge-to-edge bite considering neutral zone in maxillary anterior teeth, and good aesthetic and functional results were obtained.

Full mouth Rehabilitation with Orthognathic Surgery in Facial Asymmetry Patient : Case Report (안면 비대칭환자의 악교정 수술을 동반한 완전구강회복)

  • Im, So-Min;Shin, Hyoung-Joo;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.359-371
    • /
    • 2010
  • Facial asymmetry has been found with a higher frequency (70~84%) in skeletal class III malocclusion patients. Anticipating the poor prognosis of prosthesis due to malocclusion, occlusal stability must be obtained by orthodontic treatment. Moreover, orthodontic surgery would be needed in some severe cases for better functional and esthetic results. The orthognathic surgery is performed on one jaw or two jaw depending on the results of facial diagnosis. Genioplasty may change the vertical, horizontal, sagittal position of chin by osteotomy or augmentation using implants, also. This case is about a 24 year-old male patient who visited our clinic to solve the facial asymmetry and mandibular prognathism. Skeletal class III malocclusion, maxillary canting and menton deviation to left by 13 mm were detected. Multiple ill-fitting prostheses, unesthetic maxillary anterior prostheses, and several dental caries were found. After pre-operative orthodontic treatment, Le-Fort I osteotomy, sagittal split ramus osteotomy, genioplasty, right mandibular angle augmentation were done for the correction of jaw relation and asymmetry. By diagnostic wax-up after post-operative orthodontic treatment, maxillary full mouth rehabilitation and mandibular posterior restorations were planned out. For better result, clinical crown lengthening procedure was done on #11, 12 and implant was placed on left mandibular first molar area. The patient was satisfied with the final prostheses. Because of his high caries risk, long-term prognosis will depend on the consistent maintenance of oral hygiene and periodic follow-up.

A study on the micromotion between the dental implant and superstructure (임플란트와 상부구조물 사이의 micromotion에 관한 연구)

  • Kim, Ji-Hye;Song, Kwang-Yeob;Jang, Tae-Yeob;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).