• Title/Summary/Keyword: functional images

Search Result 504, Processing Time 0.024 seconds

Image Guided Radiation Therapy

  • Ui-Jung Hwang;Byong Jun Min;Meyoung Kim;Ki-Hwan Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.37-52
    • /
    • 2022
  • Over the past decades, radiation therapy combined with imaging modalities that ensure optimal image guidance has revolutionized cancer treatment. The two major purposes of using imaging modalities in radiotherapy are to clearly delineate the target prior to treatment and set up the patient during radiation delivery. Image guidance secures target position prior to and during the treatment. High quality images provide an accurate definition of the treatment target and the possibility to reduce the treatment margin of the target volume, further lowering radiation toxicity and improving the quality of life of cancer patients. In this review, the various types of image guidance modalities used in radiation therapy are distinguished into ionized (kilovoltage and megavoltage image) and nonionized imaging (magnetic resonance image, ultrasound, surface imaging, and radiofrequency). The functional aspects, advantages, and limitation of imaging using these modalities are described as a subsection of each category. This review only focuses on the technological viewpoint of these modalities and any clinical aspects are omitted. Image guidance is essential, and its importance is rapidly increasing in modern radiotherapy. The most important aspect of using image guidance in clinical settings is to monitor the performance of image quality, which must be checked during the periodic quality assurance process.

MR Imaging of Congenital Heart Diseases in Adolescents and Adults

  • Yeon Hyeon Choe;I-Seok Kang;Seung Woo Park;Heung Jae Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.121-131
    • /
    • 2001
  • Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  • PDF

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Metabolic Changes on Occipital Cortex during Visual Stimulation with Functional MR Imaging and H MR Spectroscopy (기능적 자기공명영상법과 양성자 가지공명분광법을 이용한 시각자극에 의한 후두염 피질의 대사물질 변화)

  • Kim, Tae;Suh, Tae-Suk;Choe, Bo-Young;Kim, Sung-Eun;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.47-52
    • /
    • 1999
  • Purpose : The purpose of this study was aimed to evaluate the BOLD(blood oxygen level dependent) contrast fMRI(functional MR imaging) in the occipital lobe and to compare with the metabolic changes based on H MRS (MR spectroscopy) and MRSI (MR spectroscopic imaging) before and after visual stimulation Materials and Methods : Healthy human volunteers (eight males and two females with 24-30 year age) participated in this study. All of the BOLD fMRI were acquired on a 1.5T MR with EPI during supervised visual stimulation in the occipital lobe. The red flicker with 8Hz was used for visual stimulation. After imaging acquisition, the MR images were transferred into unix workstation and processed with acquired from the same location based on the activation map. MRSI (magnetic resonance spectroscopic imaging) was also acquired to analyze the lactate changes before and after stimulation. Results : The activation maps were successfully produced by BOLD effect due to visual stimulation. NAA (N-acetyle aspartate)/Cr (creatine) ratio varied only from $1.79{\pm}0.28{\;}to{\;}1.88{\pm}0.20$ in activation area before and after stimulation. However, the signal intensity of lactate was elevated $9.48{\pm}4.38$ times higher than before activation. Lactate metabolite images were consistent with the activation maps. Conclusion : The BOLD contrast fMRI is enough sensitive to detect the activated area in human brain during the visual stimulation. Lactate metabolite map presents the evidence of lactate elevation on the same area of activation.

  • PDF

A Study on the Deduction of the Forest Play Activity and Space through Preschooler Participatory Workshop (유아참여 워크숍을 통한 숲놀이 활동 및 공간 요소의 도출에 관한 연구)

  • Kang, Taesun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.5
    • /
    • pp.69-81
    • /
    • 2018
  • Recently, user participatory workshops have been applied as a way to plan landscape spaces that reflects the needs and demands of the users. It is also required to improve the quality of the FECC (Forest Experience Center for Children), which is growing rapidly. Therefore, the purpose of this study is to deduct the design elements (forest play activities and space), the basic needs, and the demands of users in making the FECC a preschooler participatory workshop. For this, materials for preschooler participation were selected, and a step-by-step workshop was conducted to satisfy the demands of the preschooler's development. First, in the pre-workshops phase, design elements standards were deducted through the preschooler participatory results (41 children aged 6 and 7, Kindergarten). Second, in the main workshop phase, the design elements to be introduced on the site (Songsan-mulbit FECC) were deducted through the participating preschooler's selection and those results were analyzed. The materials used at the preschooler participatory process were 'drawing a picture' in the pre-workshop phase, and the design elements and the standard types charts were the forest play activity pictogram chart, and the forest play space general images chart in the main workshop. As for results, frst, there are 38 standard types of forest play activities that have been deducted. It consists of 27 cognitive activities (functional 16, constructive 4, symbolic 4, game on rule 3), 9 games (sensory 5, other 4), and two social play activities (solo, group). There are 21 standard types of forest play spaces. They consist of 8 play facility spaces (5 facility, 3 natural), 2 water spaces, and 11 spaces of 5 types. Second, as a result of applying the results to the site, the forest play activities to be introduced on the site were selected, and the functional play was most selected. Additionally, climbing and water play were most selected as the unit activities. Also, functional, constructive, symbolic, games based on rules were selected, even in the preschooler's development play. In the case of the forest play spaces to be introduced in the site, the preschooler's selection results by sex and age tended to be similar to the preschooler's comprehensive selection results, but the boys preferred function and adventure spaces more than the girls, while the girls preferred rest spaces more than the boys. This result is similar to the previous study results, which directly observed the preschooler's forest play behavior, and analysis that the preschooler recognized the site and selected the design elements introduced on the site. Therefore, the participatory workshop process and the materials process in this study are analyzed and applied to the purpose of the study. It is valuable as a case to be applied in design of the FECC from this point forward.

Comparison of Brain Activation Images Associated with Sexual Arousal Induced by Visual Stimulation and SP6 Acupuncture : fMRI at 3 Tesla (시각자극과 삼음교 자침으로 유발된 성적 흥분의 대뇌 활성화 영상의 비교 : 3 테슬라 기능적 자기공명영상법)

  • Choi, Nam-Gil;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.183-194
    • /
    • 2009
  • Purpose : This study was performed not only to compare the brain activation regions associated with sexual arousal induced by visual stimulation and SP6 acupuncture, but also to evaluate its differential neuro-anatomical mechanism in healthy women using functional magnetic resonance imaging (fMRI) at 3 Tesla (T). Subjects and methods : A total of 21 healthy right-handed female volunteers (mean age 22 years, range 19 to 32) underwent fMRI on a 3T MR scanner. The stimulation paradigm for sexual arousal consisted of two alternating periods of rest and activation. It began with a 1-minute rest period, 3 minutes of stimulation with either of an erotic video film or SP6 acupuncture, followed by 1-minute rest. In addition, a comparative study on the brain activation patterns between an acupoint and a shampoint nearby GB37 was performed. The fMRI data were obtained from 20 slices parallel to the AC-PC line on an axial plane, giving a total of 2,000 images. The mean activation maps were constructed and analyzed by using the statistical parametric mapping (SPM99) software. Results : As comparison with the shampoint, the acupoint showed 5 times and 2 times higher activities in the neocortex and limbic system, respectively. Note that brain activation in response to stimulation with the shampoint was not observed in the regions including the HTHL in the diencephalon, GLO and AMYG in the basal ganglia, and SMG in the parietal lobe. In the comparative study of visual stimulation vs. SP6 acupuncture, the mean activation ratio of stimulus was not significantly different to each other in both the neocortex and the limbic system (p < 0.05). The mean activities induced by both stimuli were not significantly different in the neocortex, whereas the acupunctural stimulation showed higher activity in the limbic system (p < 0.05). Conclusions : This study compared the differential brain activation patterns and the neural mechanisms for sexual arousal, which were induced by visual stimulation and SP6 acupuncture by using 3T fMRI. These findings will be useful to understand the theory of traditional acupuncture and acupoint channel in scientific point of view.

  • PDF

Study on the radiographic evaluation of marginal bone loss around short-length implant after functional loading (기능적 부하 후 "Short Implant" 주변의 골 흡수에 대한 방사선학적 연구)

  • Park, Young-Ju;Nam, Jeong-Hun;Noh, Kyung-Lok;Yeon, Byoung-Moo;Yu, Woo-Geun;Lee, Jeong-Won;Ahn, Jang-Hun;Gang, Tae-In;Park, Mi-Hee
    • The Journal of the Korean dental association
    • /
    • v.48 no.8
    • /
    • pp.615-620
    • /
    • 2010
  • Purpose: The short dental implant is considered as possible solution in the alveolar bone height deficient cases. The aim of this study was to evaluate clinical availability of short implants by measuring the marginal bone loss of short length implants and comparing with that of conventional length implants. Materials and Methods: The groups were composed of patients who had received at least one implant. The samples of this study were selected from patients who with functional loading after prosthetic treatment for 1 year follow up period. The implants with a length of 5.7 mm and 6mm were considered short. (Bicon Dental implants, USA). The experiment group was composed of $4.5{\times}6mm$, $5{\times}6mm$, $6{\times}5.7mm$ implants (total 18 implants were placed in 14 patients, 8 on maxilla, 10 on mandible). The control group was composed of $4.5{\times}8mm$, $5{\times}8mm$, $4.5{\times}11mm$, $5{\times}11mm$. All implants were selected only by implants placed on molar area. We evaluated marginal bone loss in radiographic images at baseline (implant loading) and 3, 6, 12 months after loading. Additionally, crown-to-implant ratio was evaluated, and marginal bone loss according to crown-to-implant ratio after functional loading was analyzed. Results: The short implant group had a mean marginal bone level of $-0.52{\pm}0.69mm$; the 8mm group, $-0.22{\pm}0.82mm$; and the II mm group, $-0.10{\pm}1.09mm$ after I year of functional loading. But significant differences were not detected between three groups at every follow-up period. Crown-to-implant ratio in short implant group was $1.55{\pm}0.23$; 8mm group was $1.15{\pm}0.18$; and 11mm group was $0.92{\pm}0.15$. Additionally, significant differences between three groups were founded. (P<.0001) The greatest marginal bone loss after 1 year follow-up was founded at crown-to-implant ratio 1~1.49 range in short implant. Conclusion: The marginal bone loss of short implants was comparable to that of long implants. So, the short implants can be a clinically acceptable option.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

A Study on Availability about Positron Emission Mammography of Breast Cancer (유방암 환자의 Positron Emission Mammography에서의 유용성에 관한 연구)

  • Kim, Seung-Jeong;Kim, Jae-Il;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2010
  • Purpose: Until now the general study for breast cancer patient has been mammography, breast sonography for anatomic diagnostics and $^{18}F$-FDG whole body PET for functional one. But the PEM (Positron Emission Mammography) was developed to increase sensitivity, specificity and accuracy to improve the disadvantage of each study. Therefore this present study aims to describe availability of PEM for improving diagnosis of breast cancer. Materials and Methods: During 3 months from January in 2010, PEM was performed on 100 patients who had history of breast cancer. Using Naviscan's PEM Flex Solo II scanner, PEM images of breast were acquired. And then we evaluated sensitivity, specificity and accuracy of PEM data by comparing results of PEM images with postoperative pathologic finding. Results: On the 100 patients, it could reveal 89 true positive, 9 false positive, 7 false negative and 87 true negative. Thus the results of sensitivity, specificity and accuracy for PEM was evaluated 92.7%, 90.6% and 91.7%. Conclusion: The sensitivity, specificity and accuracy have been reported 83.7%, 68.5% and 77.1% in mammography, and that was 89.1%, 79.1% and 83.4% in breast sonography. However the results of PEM were more increased than others. Therefore the results of this study will be available that PEM used diagnosis with breast cancer, used preoperative operation plan and helps to discovery of a part recurrence.

  • PDF