• Title/Summary/Keyword: functional images

Search Result 504, Processing Time 0.025 seconds

Functional MRI of Visual Cortex: Correlation between Photic Stimulator Size and Cortex Activation (시각피질의 기능적 MR 연구: 광자극 크기와 피질 활성화와의 관계)

  • 김경숙;이호규;최충곤;서대철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.114-118
    • /
    • 1997
  • Purpose: Functional MR imaging is the method of demonstrating changes in regional cerebral blood flow produced by sensory, motor, and any other tasks. Functional MR of visual cortex is performed as a patient stares a photic stimulation, so adaptable photic stimulation is necessary. The purpose of this study is to evaluate whether the size of photic stimulator can affect the degree of visual cortex activation. Materials and Methods: Functional MR imaging was performed in 5 volunteers with normal visual acuity. Photic stimulator was made by 39 light-emitting diodes on a plate, operating at 8Hz. The sizes of photic stimulator were full field, half field and focal central field. The MR imager was Siemens 1.5-T Magnetom Vision system, using standard head coil. Functional MRI utilized EPI sequence (TR/TE= 1.0/51. Omsec, matrix $No.=98{\times}128$, slice thickness=8mm) with 3sets of 6 imaging during stimulation and 6 imaging during rest, all 36 scannings were obtained. Activation images were obtained using postprocessing software(statistical analysis by Z-score), and these images were combined with T-1 weighted anatomical images. The activated signals were quantified by numbering the activated pixels, and activation a index was obtained by dividing the pixel number of each stimulator size with the sum of the pixel number of 3 study using 3 kinds of stimulators. The correlation between the activation index and the stimulator size was analysed. Results: Mean increase of signal intensities on the activation area using full field photic stimulator was about 9.6%. The activation index was greatest on full field, second on half field and smallest on focal central field in 4. The index of half field was greater than that of full field in 1. The ranges of activation index were full field 43-73%(mean 55%), half field 22-40 %(mean 32%), and focal central field 5-24%(mean 13%). Conclusion: The degree of visual cortex activation increases with the size of photic stimulator.

  • PDF

The beneficial effect of ginsenosides extracted by pulsed electric field against hydrogen peroxide-induced oxidative stress in HEK-293 cells

  • Liu, Di;Zhang, Ting;Chen, Zhifei;Wang, Ying;Ma, Shuang;Liu, Jiyun;Liu, Jingbo
    • Journal of Ginseng Research
    • /
    • v.41 no.2
    • /
    • pp.169-179
    • /
    • 2017
  • Background: Ginsenosides are the main pharmacological components of Panax ginseng root, which are thought to be primarily responsible for the suppressing effect on oxidative stress. Methods: 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity and oxygen radical absorption capacity were applied to evaluate the antioxidant activities of the ginsenosides. Human embryonic kidney 293 (HEK-293) cells were incubated with ginsenosides extracted by pulsed electric field (PEF) and solvent cold soak extraction (SCSE) for 24 h and then the injury was induced by $40{\mu}M$ $H_2O_2$. The cell viability and surface morphology of HEK-293 cells were studied using MTS assay and scanning electron microscopy, respectively. Dichloro-dihydro-fluorescein diacetate fluorescent probe assay was used to measure the level of intracellular reactive oxygen species. The intracellular antioxidant activities of ginsenosides were evaluated by cellular antioxidant activity assay in HepG2 cells. Results: The PEF extracts displayed the higher 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity and stronger oxygen radical absorption capacity (with an oxygen radical absorption capacity value of $14.48{\pm}4.04{\mu}M\;TE\;per\;{\mu}g/mL$). The HEK-293 cell model also suggested that the protective effect of PEF extracts was dose-dependently greater than SCSE extracts. Dichloro-dihydro-fluorescein diacetate assay further proved that PEF extracts are more active (8% higher than SCSE extracts) in reducing intracellular reactive oxygen species accumulation. In addition, scanning electron microscopy images showed that the HEK-293 cells, which were treated with PEF extracts, maintained more intact surface morphology. Cellular antioxidant activity values indicated that ginsenosides extracted by PEF had stronger cellular antioxidant activity than SCSE ginsenosides extracts. Conclusion: The present study demonstrated the antioxidative effect of ginsenosides extracted by PEF in vitro. Furthermore, rather than SCSE, PEF may be more useful as an alternative extraction technique for the extraction of ginsenosides with enhanced antioxidant activity.

Feasibility of Proton Chemical Shift Imaging with a Stereotactic Headframe

  • 백현만;최보영;손병철;정성택;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.72-72
    • /
    • 2003
  • Purpose: To prove feasibility of proton chemical shift imaging (lH CSI) during stereotactic procedure, authors performed IH CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, evaluated the pathologic results. Methods: The 1H CSI directed stereotactic biopsy was performed in five patients. 1H CSI was performed before conventional stereotactic MRI with gadolinium enhancement for stereotactic coordinates. The metabolite images expressed as integral ratios, Cho/Cr and Lac/Cr, were displayed in different colors. The stereotactic target coordinates were correlated with the coordinates from the 1H CSI images. Results: The final pathologic results obtained were concordant with the local metabolic information from 1H CSI. We believe that 1H CSI-directed stereotatic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting. Conclusions : Metabolic signals derived from 1H CSI could give us more direct clues for stereotactic target selection during the subsequent conventional stereotactic MR imaging. 1H CSI was feasible with the stereotatic headframe in place. The final pathologic results obtained were concordant with the local metabolic information from 1H CSI. Acknowledgement: This study was supported by a grant of the Center for Functional and Metabolic Imaging Technology, Ministry of Health & Welfare, Republic of Korea (02-PJ3-PG6-EV07-0002).

  • PDF

Electron Microscopic Study on the Hepatocyte and Bile Canaliculus of the Fasted Mice (기아 마우스 담세관의 전자현미경적 연구)

  • Park, Chang-Hyun;Shin, Young-Chul;Jang, Byung-Joon
    • Applied Microscopy
    • /
    • v.26 no.2
    • /
    • pp.207-219
    • /
    • 1996
  • This study was designed to investigate the ultrastructural alterations of the hepatocyte and bile canaliculus of the fasted mice with transmission and scanning electron microscopes. The morphometry was also carried out for the caliber of the bile canaliculus and the number, length and thickness of the microvillus. The hepatocyte observed in the three day fasting group showed ultrastructural images of active function. The dilated bile canaliculi, especially of type II were increased in number as compared with those seen in the normal group. However, the hepatocyte observed in the six day fasting group showed ultrastructural images of inactive function. The bile canaliculi without dilation (type I) were increased in number. The number of microvilli were identical with one another among the different types of bile canaliculi, while their length and thickness were reduced in the dilated bile canaliculi. From the evidence, the luminal size of the bile canaliculi seems to be easily changeable according to the functional state of the hepatocyte. However, the microvilli may not be changed in number but may be changed length and thickness when the bile canaliculi are dilated.

  • PDF

Advanced JPEG bit rate control for the mobile multimedia device (이동형 멀티미디어 기기를 위한 개선된 JPEG 비트율 조절 알고리즘)

  • Yang, Yoon-Gi;Lee, Chang-Su;Kim, Jin-Yul
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.5
    • /
    • pp.579-587
    • /
    • 2008
  • Typically, the file sizes of JPEG compressed images with various complexity differ from images regardless of same image size. So, it is not easy to estimate the remaining image counts that should be stored in the limited storage equipped with the digital camera. To solve the problem, the bit rate control employs the modification of quantization table. The previous work assumed that there is linear relation between image activity and modification factor of quantization table, but in this paper, more accurate functional relations based on statistics are employed to improve the bit rate control accuracy. Computer simulations reveals that the standard deviation of the bit rate error of the proposed scheme is 50% less than that of the conventional method.

  • PDF

Cerebral Activation Area Following Oxygen Administration using a 3 Tesla Functional MR Imaging (고 자장 기능적 MR 영상을 이용한 뇌 운동 영역에서 산소 주입에 따른 활성화 영역에 관한 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.47-53
    • /
    • 2005
  • This study aim to investigate the effects of supply of oxygen enhances cerebral activation through increased activation in the brain and using a 3 Tesla fMRI system. Five volunteers (right handed, average age of 21.3) were selected as subjects for this study. Oxygen supply equipment that provides 30% oxygen at a constant rate of 15L/min was given using face mask. A 3 Tesla fMRI system using the EPI BOLD technique, and three-pulse sequence technique get of the true axial planes scanned brain images. The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers. Complex movement consisted of a finger task in which subjects flexed and extended all fingers repeatedly in union, without the fingers touching each other. Both task consisted of 96 phases including 6 activations and rests contents. Post-processing was done on MRDx software program by using cross-correlation method. The result shows that there was an improvement in performance and also increased activation in several areas in the oxygen method. These finding demonstrates that while performing cognitive tasks, oxygen administration was due to increase of cerebral activation.

Disparity Estimation using a Region-Dividing Technique and Edge-preserving Regularization (영역 분할 기법과 경계 보존 변이 평활화를 이용한 스테레오 영상의 변이 추정)

  • 김한성;손광훈
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.25-32
    • /
    • 2004
  • We propose a hierarchical disparity estimation algorithm with edge-preserving energy-based regularization. Initial disparity vectors are obtained from downsampled stereo images using a feature-based region-dividing disparity estimation technique. Dense disparities are estimated from these initial vectors with shape-adaptive windows in full resolution images. Finally, the vector fields are regularized with the minimization of the energy functional which considers both fidelity and smoothness of the fields. The first two steps provide highly reliable disparity vectors, so that local minimum problem can be avoided in regularization step. The proposed algorithm generates accurate disparity map which is smooth inside objects while preserving its discontinuities in boundaries. Experimental results are presented to illustrate the capabilities of the proposed disparity estimation technique.

Motion Correction in PET/CT Images (PET/CT 영상 움직임 보정)

  • Woo, Sang-Keun;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.172-180
    • /
    • 2008
  • PET/CT fused image with anatomical and functional information have improved medical diagnosis and interpretation. This fusion has resulted in more precise localization and characterization of sites of radio-tracer uptake. However, a motion during whole-body imaging has been recognized as a source of image quality degradation and reduced the quantitative accuracy of PET/CT study. The respiratory motion problem is more challenging in combined PET/CT imaging. In combined PET/CT, CT is used to localize tumors and to correct for attenuation in the PET images. An accurate spatial registration of PET and CT image sets is a prerequisite for accurate diagnosis and SUV measurement. Correcting for the spatial mismatch caused by motion represents a particular challenge for the requisite registration accuracy as a result of differences in PET/CT image. This paper provides a brief summary of the materials and methods involved in multiple investigations of the correction for respiratory motion in PET/CT imaging, with the goal of improving image quality and quantitative accuracy.

Analysis of Anisotropic Characteristic in Fiber Reinforced Polymer for the Knee Brace Using the Eddy Current Inspection (와전류 탐상기법을 이용한 무릎보조기용 섬유강화 폴리머의 이방특성 분석)

  • Kim, Cheol-Woong;Park, Cheon-Woong;Shin, Yong-Hoon;Seo, Hae-Young;Lee, Ho-Sang
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1533-1538
    • /
    • 2008
  • The development of new material systems like Carbon Fiber Reinforced Polymer (CFRP) places ever higher demands on the techniques for non-destructive material characterisation. Image-producing eddy current methods also need to satisfy these demands. Eddy-current imaging of FRP is based on the anisotropic electrical properties of the material investigated. Significant differences in conductivity between carbon fibres, polymer matrix and integrated functional components can be found. The availability of high-resolution sensors enables access to the local distribution of the electromagnetic properties. The static and dynamic procedures for isolating influential characteristics, already in use in eddy-current technology, can now be supplemented by topographical images. The precondition for a successful implementation of the eddy-current procedure is a deeper understanding of the image-generating process which allows correct interpretation of the images obtained.

  • PDF

Noise Removal of Images Using the Median Rule Cellular Automata (미디안 규칙을 갖는 셀룰러 오토마타를 이용한 화상의 잡음제거)

  • 김석태
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.638-642
    • /
    • 2001
  • In this paper we propose a noise reduction algorithm which based on cellular automata with the local median rule. It is supposed that there is no information about the features of the image that must be improved. The proposed method behavior is to locally increase or decrease the gray level differences of the image without loss of the main characteristics of the image. The dynamical behavior of these automata is completely determined by Lyapunov operators for sequential and parallel update. We have found that the automata present very fast convergence to fixed points, stability in front of random noisy images. Based on the experimental results we discuss the advantage and efficiency.

  • PDF