• Title/Summary/Keyword: functional failure

Search Result 494, Processing Time 0.024 seconds

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF

Early and Mid-term Results of Operation for Infective Endocarditis on Mitral Valve (감염성 승모판 심내막염의 중단기 수술 성적)

  • Ahn, Byong-Hee;Chun, Joon-Kyung;Yu, Ung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Park, Jong-Chun;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • Background: Infective endocarditis shows higher operative morbidity and mortality rates than other cardiac diseases. The vast majority of studies on infective endocarditis have been made on aortic endocarditis, with little attention having been paid to infective endocarditis on the mitral valve. This study attempts to investigate the clinical aspects and operative results of infective endocarditis on the mitral valve. Meterial and Method: The subjects of this study consist of 23 patients who underwent operations for infective endocariditis on the mitral valve from June 1995 to May 2003. Among them, 2 patients suffered from prosthetic valvular endocarditis and the other 21 from native valvular endocarditis. The subjects were evenly distributed age-wise with an average age of 44.8$\pm$15.7 (11∼66) years. Emergency operations were performed on seventeen patients (73.9%) due to large vegetation or instable hemodynamic status. In preoperative examinations, twelve patients exhibited congestive heart failure, four patients renal failure, two patients spleen and renal infarction, and two patients temporary neurological defects, while one patient had a brain abscess. Based on the NYHA functional classification, seven patients were determined to be at Grade II, 9 patients at Grade III, and 6 patients at Grade IV. Vegetations were detected in 20 patients while mitral regurgitation was dominant in 19 patients with 4 patients showing up as mitral stenosis dominant on the preoperative echocardiogram. Blood cultures for causative organisms were performed on all patients, and positive results were obtained from ten patients, with five cases of Streptococcus viridance, two cases of methicillin-sensitive Staphylococcus aureus, and one case each of Corynebacteriurn, Haemophillis, and Gernella. Operations were decided according to the AA/AHA guidelines (1988). The mean follow-up period was 27.6 $\pm$23.3 (1 ∼ 97) months. Result: Mitral valve replacements were performed on 43 patients, with mechanical valves being used on 9 patients and tissue valves on the other 4. Several kinds of mitral valve repair or mitral valvuloplasty were carried out on the remaining 10 patients. Associated procedures included six aortic valve replacements, two tricuspid annuloplasty, one modified Maze operation, and one direct closure of a ventricular septal defect. Postoperative complications included two cases of bleeding and one case each of mediastinitis, low cardiac output syndrome, and pneumonia. There were no cases of early deaths, or death within 30 days following the operation. No patient died in the hospital or experienced valve related complications. One patient, however, underwent mitral valvuloplasty 3 months after the operation. Another patient died from intra-cranial hemorrhage in the 31st month after the operation. Therefore, the valve-related death rate was 4.3%, and the valve-related complication rate 8.6% on mid-term follow-up. 1, 3-, and 5-year valve- related event free rates were 90.8%, 79.5%, and 79.5%, respectively, while 1, follow-up. 1, 3-, and 5-year valve- related event free rates were 90.8%, 79.5%, and 79.5%, respectively, while 1, 3-, and 5-year survival rates were 100%, 88.8%, and 88.8%, respectively. Conclusion: The findings suggest that a complete removal of infected tissues is essential in the operative treatment of infectious endocarditis of the mitral valve. It is also suggested that when infected tissues are completely removed, neither type of material nor method of operation has a significant effect on the operation result. The postoperative results also suggest the need for a close follow-up observation of the patients suspected of having brain damage, which is caused by preoperative blood contamination or emboli from vegetation, for a possible cerebral vascular injury such as mycotic aneurysm.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.

Endoventricular Circular Patch Plasty (Dor Procedure) for Ischemic Left Ventricular Dysfunction (허혈성 좌심실 부전증에서의 좌심실내 원형 패취성형술)

  • Cho, Kwang-Ree;Lim, Cheong;Choi, Jae-Sung;Hong, Jang-Mee;Kim, Hyeong-Ryul;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.755-761
    • /
    • 2004
  • We evaluated the efficacy of Dor procedure in patients with ischemic left ventricular dysfunction. Material and Method: Between April 1998 and December 2002, 45 patients underwent the Dor procedure con-comitant with coronary artery bypass grafting (CABG). Left ventricular ejection fraction (LVEF) and left ventricular end-diastolic/end-systolic volumes (LVEDV/LVESV) were measured by echocardiography, myocardial SPECT, and cardiac catheterization and angiography performed at the sequence of preoperative, early postoperative, and one year postoperative stage. Result: Cardiopulmonary bypass and aortic clamp times were mean 141$\pm$64, 69$\pm$24 minutes, respectively. Intraaortic balloon pump (IABP) therapy was required in 19 patients (42%; 7 preoperatively, 9 intraoperatively, 3 postoperatively). Operative mortality rate was 2.2% (1/45). Postoperative morbidities were low cardiac output syndrome (12), atrial fibrillation (5), acute renal failure (4), and postoperative bleeding (4). Functional class (NYHA) was improved from classes 2.8 to 1.1 (p < 0,01). When we compared between the preoperative and early postoperative values, LVEF was improved from 32$\pm$9% to 52$\pm$11% (p<0.01). The asynergy portion decreased from 57$\pm$12% to 22$\pm$9%, and LVEDV/LVESV indexes improved from 125$\pm$39 mL/$m^2$, 85$\pm$30 mL/$m^2$ to 66$\pm$23 mL/$m^2$, 32$\pm$16 mL/$m^2$ (p<0.01). Although these changes in volumes were relatively preserved at postoperative one year, the left ventricular volumes showed a tendency to increase. Conclusion: After the Dor procedure for ischemic left ventricular dysfunction, LVEF improvement and left ventricular volume reduction were maintained till postoperative one year. The tendency for left ventricular volume to increase at postoperative one year suggested the requirement of strict medical management.

Early and Mid-term Results of Operation for Acute Limb Ischemia (급성 사지 허혈증의 증단기 수술 성적)

  • 김대환;최창석;황상원;김한용;유병하;김종석
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.787-792
    • /
    • 2004
  • Even though there well developments in various treatment techniques for acute limb ischemia, this disease is both life threatening and limb threatening. We investigated early and mid-term results of operation for acute limb ischemia with symptoms, the combined diseases, location of occlusion, complication in our patients. Material and Method: A retrospective review was conducted in 54 patients (43 men, 11 women, mean age 67.2 years) presenting with acute limb ischemia due to arterial thrombosis or embolism between Jan. 1996 and Dec. 2003, initially underwent thromboembolectomy. Result: In 33 patients (61.1%) the timeinterval from the onset of symptom to admission was within 24 hours. Causes of acute limb ischemia were embolic occlusion (27.8%), native arterial thrombosis (66.7%), and bypass graft thrombosis (5.6%). The distribution of arterial occlusion location was at 8 aortoiliac (14.8%) and 43 distal to femoral (79.6%) and brachial (5.6%). Clinical categories were grade I in 64.8%, IIa in 24.1%, IIb in 7.4%, and III in 3.7%, All the patients were received embolectomy. Underlying diseases were heart disease (72.2%), hypertension (33.3%), cerebrovascular accident (16.7%) and diabetes (18.5%). History of smoking was noted in 96,3% of the cases. Mortality rate was 5.6% and overall amputation rate was 9.3% (5/54). The 1-year limb salvage rate was 93.62%. Postoperative complications were 1 wound infection, 1 G1 bleeding, 3 acute renal failure, and 1 compartment syndromes. The functional outcomes of the salvaged limb according to the recommended scale for gauging changes in clinical status, revised version in 1997 were +3 in 68.5%, +2 in 9.3%, +1 in 7.4%, -1 in 5.6%, -2 in 3.7%, and -3 in 5.6%. Conclusion: This study revealed 5.6% mortality and the amputation rate was 9.3%. We have retrospectively shown good results from early diagnosis & early operation. To improve outcome, early diagnosis and understand the underlying diseases, prompt treatment and operation would be appreciated.

Mitral valve Replacement (승모판막 치환술)

  • Sin, Dong-Geun;Kim, Min-Ho;Jo, Jung-Gu
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.137-145
    • /
    • 1997
  • From July 1983 to December 1993, total 112 consecutive mitral valve replacements in 107 patients were performed in patient with mitral valvular abnormalities. To estimate the risk factor related to operative death, all patient's perioperative data were reviewed retrospectively. Except 20 patients received concomitant aortic valve replacement and 2 patients had incomplete data, 85 patients were included in this study. Mean age were $37.3\pm$ 13.1 years ranging from 13 to 72 years. Thirty-seven patients were male and fourty-eight patients were female. Mean follow-up durations were $51.1\pm33.8$ months ranging from 6 months t 11 years. Patients in this study showed improvement in mean NYHA functional clssification, from $3.02\pm0.73$ to 1 $78\pm0.55,$ and also in cardiothoracic ratio, from 0.61 $\pm0.09$ to $0.58\pm0.08$ at 6 months follow-up after operation. Operative complications were detected in 23 patients(27.1 %) and common postoperative complications were rhythm disturbance in 7 cases, pulmonary complications in 6 cases and low cardiac output syndrome in 6 cases. Early mortality was 10.6%(n=9) and the most common cause of death was a congestive heart failure due to low cardiac output syndrome. Main cause of our higher operative mortality than other study was that operative mortality in the initial period of our mitral surgery was high(5 operative deaths among 19 mitral valve replacement from July 1983 to December 1985). Actuarial survival was 80.8% at 5 years, 71.8% at 11 years including operative deaths. Actuarial freedom from anticoagulant-related bleeding was 85.3% at 5 years, 78.3% at 11 years. 95.1% at 5 years and 88.8% at 11 years among the patient in this study were free from thromboembolism, and 97.5% at 5 years and 75.1% at 11 years were free from reoperation. Preoperative cardiothoracic ratio and patient's age were statistically significant operative risk factors.

  • PDF

LIM Implementation Method for Planning Biotope Area Ratio in Apartment Complex - Focused on Terrain and Pavement Modeling - (공동주택단지의 생태면적률 계획을 위한 LIM 활용방법 - 지형 및 포장재 모델링을 중심으로 -)

  • Kim, Bok-Young;Son, Yong-Hoon;Lee, Soon-Ji
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.3
    • /
    • pp.14-26
    • /
    • 2018
  • The Biotope Area Ratio (BAR) is a quantitative pre-planning index for sustainable development and an integrated indicator for the balanced development of buildings and outdoor spaces. However, it has been pointed out that there are problems in operations management: errors in area calculation, insufficiency in the underground soil condition and depth, reduction in biotope area after construction, and functional failure as a pre-planning index. To address these problems, this study proposes implementing LIM. Since the weights of the BAR are mainly decided by the underground soil condition and depth with land cover types, the study focused on the terrain and pavements. The model should conform to BIM guidelines and standards provided by government agencies and professional organizations. Thus, the scope and Level Of Detail (LOD) of the model were defined, and the method to build a model with BIM software was developed. An apartment complex on sloping ground was selected as a case study, a 3D terrain modeled, paving libraries created with property information on the BAR, and a LIM model completed for the site. Then the BAR was calculated and construction documents were created with the BAR table and pavement details. As results of the study, it was found that the application of the criteria on the BAR and calculation became accurate, and the efficiency of design tasks was improved by LIM. It also enabled the performance of evidence-based design on the terrain and underground structures. To adopt LIM, it is necessary to create and distribute LIM library manuals or templates, and build library content that comply with KBIMS standards. The government policy must also have practitioners submit BIM models in the certification system. Since it is expected that the criteria on planting types in the BAR will be expanded, further research is needed to build and utilize the information model for planting materials.

A Destructive Method in the Connection of the Algorithm and Design in the Digital media - Centered on the Rapid Prototyping Systems of Product Design - (디지털미디어 환경(環境)에서 디자인 특성(特性)에 관한 연구(硏究) - 실내제품(室內製品) 디자인을 중심으로 -)

  • Kim Seok-Hwa
    • Journal of Science of Art and Design
    • /
    • v.5
    • /
    • pp.87-129
    • /
    • 2003
  • The purpose of this thesis is to propose a new concept of design of the 21st century, on the basis of the study on the general signification of the structures and the signs of industrial product design, by examining the difference between modern and post-modern design, which is expected to lead the users to different design practice and interpretation of it. The starting point of this study is the different styles and patterns of 'Gestalt' in the post-modern design of the late 20th century from modern design - the factor of determination in industrial product design. That is to say, unlike functional and rational styles of modern product design, the late 20th century is based upon the pluralism characterized by complexity, synthetic and decorativeness. So far, most of the previous studies on design seem to have excluded visual aspects and usability, focused only on effective communication of design phenomena. These partial studies on design, blinded by phenomenal aspects, have resulted in failure to discover a principle of fundamental system. However, design varies according to the times; and the transformation of design is reflected in Design Pragnanz to constitute a new text of design. Therefore, it can be argued that Design Pragnanz serves as an essential factor under influence of the significance of text. In this thesis, therefore, I delve into analysis of the 20th century product design, in the light of Gestalt theory and Design Pragnanz, which have been functioning as the principle of the past design. For this study, I attempted to discover the fundamental elements in modern and post-modern designs, and to examine the formal structure of product design, the users' aesthetic preference and its semantics, from the integrative viewpoint. Also, with reference to history and theory of design my emphasis is more on fundamental visual phenomena than on structural analysis or process of visualization in product design, in order to examine the formal properties of modern and post-modern designs. Firstly, In Chapter 1, 'Issues and Background of the Study', I investigated the Gestalt theory and Design Pragnanz, on the premise of formal distinction between modern and post-modern designs. These theories are founded upon the discussion on visual perception of Gestalt in Germany in 1910's, in pursuit of the principle of perception centered around visual perception of human beings. In Chapter 2, I dealt with functionalism of modern design, as an advance preparation for the further study on the product design of the late 20th century. First of all, in Chapter 2-1, I examined the tendency of modern design focused on functionalism, which can be exemplified by the famous statement 'Form follows function'. Excluding all unessential elements in design - for example, decoration, this tendency has attained the position of the international style based on the spirit of Bauhause - universality and regularity - in search of geometric order, standardization and rationalization. In Chapter 2-2, I investigated the anthropological viewpoint that modern design started representing culture in a symbolic way including overall aspects of the society - politics, economics and ethics, and its criticism on functionalist design that aesthetic value is missing in exchange of excessive simplicity in style. Moreover, I examined the pluralist phenomena in post-modern design such as kitsch, eclecticism, reactionism, hi-tech and digital design, breaking away from functionalist purism of modern design. In Chapter 3, I analyzed Gestalt Pragnanz in design in a practical way, against the background of design trends. To begin with, I selected mass product design among those for the 20th century products as a target of analysis, highlighting representative styles in each category of the products. For this analysis, I adopted the theory of J. M Lehnhardt, who gradated in percentage the aesthetic and semantic levels of Pragnantz in design expression, and that of J. K. Grutter, who expressed it in a formula of M = O : C. I also employed eight units of dichotomies, according to the G. D. Birkhoff's aesthetic criteria, for the purpose of scientific classification of the degree of order and complexity in design; and I analyzed phenomenal aspects of design form represented in each unit. For Chapter 4, I executed a questionnaire about semiological phenomena of Design Pragnanz with 28 units of antonymous adjectives, based upon the research in the previous chapter. Then, I analyzed the process of signification of Design Pragnanz, founded on this research. Furthermore, the interpretation of the analysis served as an explanation to preference, through systematic analysis of Gestalt and Design Pragnanz in product design of the late 20th century. In Chapter 5, I determined the position of Design Pragnanz by integrating the analyses of Gestalt and Pragnanz in modern and post-modern designs In this process, 1 revealed the difference of each Design Pragnanz in formal respect, in order to suggest a vision of the future as a result, which will provide systemic and structural stimulation to current design.

  • PDF

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

Clinical Evaluation of Patients with Unilateral Non-functioning Kidney on $^{99m}Tc-DMSA$ scan ($^{99m}Tc-DMSA$ 스캔에서 일측성으로 동위원소 섭취가 안되는 환아들에 대한 임상적 고찰)

  • Bae Hyun-Chul;Kim Hyun-Young;Kim Pyung-Kil;Han Sang-Won
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 1997
  • The DMSA scan is a useful radiologic study in diagnosis of morphologic and functional diseases of kidney. We evaluated the distribution of sex and age, clinical manifestations, diagnosis, combined diseases, treatment and prognosis of the 61 patients with non-functioning kidney(no isotope uptake or uptake below 5% in DMSA scan) who admitted in our hospital from 1980 to 1995. The proportion of patients under 1 year old age was 46%. Sex ratio was 1.4:1 with male predominance. Most diagnosis of non-functioning kidneys were congenital such as multicystic dysplastic kidney, hydronephrosis due to ureteropelvic junction obstruction, renal agenesis and renal hypoplasia. In order of frequency thirty one percent of them were previously detected on antenatal ultrasonogram. Treatment consisted of operation in 47.5%, mostly nephrectomy and 32.8% of patients were followed up at OPD base without definite treatment. The most common combined diseases was hydronephrosis, in 4patients who had both kidneys inveloved progressed to chronic renal failure, but the prognosis in most cases were good. It is important to evaluate renal diseases in perinatal periods, and we believe that highly sensitive diagnostic study contribute to early treatment plan and thus to good prognosis.

  • PDF