• 제목/요약/키워드: function-safe

검색결과 728건 처리시간 0.026초

폐 기능검사가 불량한 2기 폐암환자에서 시행한 우전폐절제술 - l예 보고 - (Rt. Pneumonectomy in a Lung Cancer Patient with Poor Pulmonary function Test - A Case Report -)

  • 진웅;이선희;전진영;홍성진;심성보;박재길;곽문섭
    • 대한기관식도과학회지
    • /
    • 제6권2호
    • /
    • pp.192-195
    • /
    • 2000
  • Pulmonary function test is used as a guideline for safe pulmonary resection without complications. Usually FEVl lower than 1 liter is considered as a contraindication of lobectomy. Therefore, the curative operation of resectable lung cancer can not be performed in the case of poor pulmonary functions. Nowadays, there are some arguing points about the value of preoperative PFTs before the pulmonary resection. We performed a right pneumonectomy for stage H lung cancer in a patient with poor lung function test; FVC 2.17L, FEVl 0.97L, FEVl/FVC 44%, FEF 25-75% 0.42L/sec, MVV 28L/min, TLC 5.18L, RV 2.99. During 4 months follow up, the patient had been tolerable. The follow up PFTs at postoperative 3 months 18 days showed up as follows; FVC 1.20L, FEVI 0.63L, FEVl/FVC 53%, FEF 25-75% 0.31L/sec, MVV 25L/min, TLC 3.80L, RV 2.33L.

  • PDF

체중지지를 위한 레일형 보행 재활 시스템 구조 해석 (Structural Analysis of the Gait Rehabilitation System of a Rail Type for Body-Weight Support Function)

  • 김재준;김경;서영수;김재원;김제남;정우석;유창호;권대규;송원경
    • 한국정밀공학회지
    • /
    • 제33권9호
    • /
    • pp.761-768
    • /
    • 2016
  • Weight bearing is effective during rehabilitation of gait, in the elderly and disabled people. Various training devices using weight bearing function were developed along with treadmill walking; however, no device has been developed in conjunction to walking on the ground. Here, we designed a rail type frame of a gait rehabilitation system for body-weight support (BWS) function, and analyzed its mechanical safety in the static weight bearing condition of a vertical axis. Computational simulations were performed to analyze structure of the driving parts, which are connected with a rail and driving rollers and the lower plate of the BWS. Structural analyses showed the drivers and BWS were safe, when simulated at 135kg weight under static conditions. Thus, this rail type rehabilitation system can be used for gait training of the elderly and disabled.

스트레스와 소화기능을 활용한 체질별 맞춤 수면관리 (Individualized Sleep Management for Each Sasang Type Using Stress and Digestive Function)

  • 이슬;채한;박지은;김국화;이정윤
    • 사상체질의학회지
    • /
    • 제36권1호
    • /
    • pp.13-30
    • /
    • 2024
  • Objectives This study aimed to analyze the influence of various sleep-related factors that affect sleep quality by each Sasang type. Methods A total of 400 subjects were included for this study, 108 males and 292 females. Sasang type was diagnosed using the SCAT. Then, the characteristics of each Sasang type were analyzed using HRV, DITI, and PSQI, PSS, and SDFI questionnaires. Logistic regression analysis was used to predict sleep-related factors that affect sleep disorders by Sasang types. Results This study shows that the pathophysiological characteristics for stress and digestive function of each Sasang type can differentiate sleep management through a logistic regression model including subscales of PSS and SDFI. Stress had no effect on the occurrence of sleep disturbance within only So-Eum, since the stress level is originally high in the So-Eum regardless of sleep quality. Rather, decreased appetite and poor eating habits had a significant impact on the decline in sleep quality. In addition, poor digestion and eating habits in So-Yang had a greater impact and poor digestion in Tae-Eum had a greater impact on the decline in sleep quality. Conclusion The stress and subscales of digestive function provide differentiated sleep management in So-Yang, Tae-Eum, and So-Eum types. The individualized sleep management for each Sasang type with statistically validated PSS and SDFI would be useful for sleep-related experts planning safe and effective person-centered health care as well as for Western clinicians who want to incorporate Sasang typology into their treatments as integrative medical technique in the future.

감수(甘遂)를 이용한 사하법(瀉下法)의 안전성에 대한 후향적 연구: 임상반응, 간기능, 신기능을 중심으로 한 평가 (Retrospective Study for Safety of Xie-xia Fa (瀉下法) by Euphorbia kansui Radix: Analysis of Clinical Features, Liver and Kidney Functions)

  • 이승욱;권오준;나현영;안영민;이병철;안세영
    • 대한한방내과학회지
    • /
    • 제35권4호
    • /
    • pp.472-482
    • /
    • 2014
  • Objectives: The purpose of this study was to report the safety of diarrhea-inducing treatment (Xie-xia Fa, 瀉下法) by Euphorbia kansui Radix, especially in the respect of clinical features, liver and kidney functions. Methods: Patients who were treated with Euphorbia kansui Radix powder between September 2013 and September 2014 were assessed retrospectively. Results: Less than 6 grams dosage of Euphorbia kansui Radix can induce several mild intestinal reactions but have no harmful effects on liver and kidney functions. Conclusions: Through this study, diarrhea-inducing treatment by less than 6 grams of Euphorbia kansui Radix can considered safe enough to be used in local clinics, but a cautious approach is needed.

신경퇴화 및 지적장애 예방에 관한 고지능검사도구 이용의 실효성 연구 (The Efficiency of Intelligence Quotient Test at Prevention of Mental Retardation and Dementia)

  • 염승민;전상훈;이민기;김다은;양대욱
    • 보건의료산업학회지
    • /
    • 제7권2호
    • /
    • pp.101-111
    • /
    • 2013
  • To develop the Korean-Version-Improvement program for ordinary people, we investigate how Korean-High-Intelligent people use their cognitive function, intellectual capacity and Intelligent Quotient test. Using Mensa iq test, we classify intelligent examination tool into various components; visual, geometrical component and cognitive interpretation component. Also we organized each component, got database of intelligent subjects sample, classified itemized availability. Based on these things, we prove efficiency of intelligent examination tool. We found out that high intelligent people showed high Intelligent Index using visual cognitive stimulation with cognitive function when subjects were exposed to certain situation; solving the problem. This intelligent examination tool is low price and safe and easily carrying out with personal computer. If we develop intelligence quotient examination customized with mental retardation populations, a variety of subjects will improve their cognition with efficiency and inexpensively.

실리콘 보형물을 이용한 척추측만증 배부 윤곽변형 교정수술 (Correction of the Dorsal Contour Deformity Caused by Scoliosis with Silicone Implant)

  • 박지웅;조상헌;신종인;김창연
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.792-795
    • /
    • 2007
  • Purpose: Scoliosis is a multifactorial disorder caused by genetic, biochemical, developmental, neuromuscular factors and causes complex deformities which include skeletal deformity, pain, cardiovascular dysfunction, motor function disorder. Until now, the treatment of scoliosis have been focused on orthopedic correction, preservation of cardiopulmonary and neurologic function. But recently, as aesthetic demands increases, the needs for the correction or improvement of the trunk and extremity contour does. So, the correction of soft tissue contour deformity can be a new concept for the treatment of scoliosis. Methods: We corrected a deformed contour with prefabricated silicone implant in a scoliosis patient who had been operated for orthopedic correction previously. Submuscular pocket was made under trapezius and latissimus dorsi muscle. Silicone implant was placed in the pocket and fixed to thoracolumbar fascia with sutures. Results: We had a satisfactory results for the correction of contour deformity. There was no significant complication. Conclusion: Silicone implant is a new trial for the correction of scoliosis contour deformity. This method is simple, safe and brings on satisfactory results.

Effectiveness of Physical Therapy Management of Axillary Web Syndrome following Sentinel Lymph Node Biopsy in Breast Cancer Patients: Case Study

  • Shim, Young-Hun;Chae, Yun-Won;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • 제28권2호
    • /
    • pp.142-148
    • /
    • 2016
  • Purpose: The aim of this pilot study was to determine the effect of soft tissue technique (STT) in Axillary Web Syndrome (AWS) following sentinel Lymph Node Biopsy in breast cancer patients by examining the upper extremity function, range of motion, and pain. Methods: Nineteen patients with breast cancer-related AWS were evaluated. STT was performed on the symptom area for treatment of AWS symptoms. We evaluated AWS symptoms and pain intensity using a visual analogue scale (VAS), and functional disability using the Korean version of the Disabilities of Arm, Shoulder, and Hand (DASH) questionnaire, glenohumeral joint (GHJ) flexion and abduction range of motion (ROM) with or without elbow extension. Results: Visual analyses of the data suggest a modest effect of STT in improving GHJ flexion, abduction ROM with or without elbow extension, DASH for upper extremity function, and Pain. The statistically significant improvement in baseline observed for pain, DASH, and ROM data made it impossible to assess the effects of STT on those outcomes. There were no adverse events. Conclusions: STT may be an effective and safe treatment option for AWS patients recovering from breast cancer treatment; however, further research is needed.

Test Platform Development of Vessel's Power Management System Using Hardware-in-the-Loop Simulation Technique

  • Lee, Sang-Jung;Kwak, Sang-Kyu;Kim, Sang-Hyun;Jeon, Hyung-Jun;Jung, Jee-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2298-2306
    • /
    • 2017
  • A PMS (Power Management System) controls vessel's power systems to improve the system efficiency and to protect a blackout condition. The PMS should be developed with considering the type and the capacity of the vessel's power system. It is necessary to test the PMS functions developed for vessel's safe operations under various sailing situations. Therefore, the function tests in cooperation with practical power systems are required in the PMS development. In this paper, a hardware-in-the-loop (HIL) simulator is developed for the purposes of the PMS function tests. The HIL simulator can be more cost-effective, more time-saved, easier to reproduce, and safer beyond the normal operating range than conventional off-line simulators, especially at early stages in development processes or during fault tests. Vessel's power system model is developed by using a MATLAB/SIMULINK software and by communicating between an OPAL-RT's OP5600 simulator. The PMS uses a Modbus communication protocol implemented using LabVIEW software. Representative tests of the PMS functions are performed to verify the validity of the proposed HIL-based test platform.

대두 이소플라본 섭취가 흰쥐에서 미로수행능력과 뇌 중 Acetylcholinesterase 활성에 미치는 영향 (Effect of Soy Isoflavone Intake on Water Maze Performance and Brain Acetylcholinesterase Activity in Rats)

  • 오현경;김선희
    • Journal of Nutrition and Health
    • /
    • 제39권3호
    • /
    • pp.219-224
    • /
    • 2006
  • This study was performed to determine the effect of soy isoflavones on brain development and function in rats. Forty Sprague-Dawley male rats were provided diets containing different levels of soy isoflavones for 6 weeks; 0 ppm (control), 50 ppm (low isoflavone intake; LI), 250 ppm (medium isoflavone intake; MI) and 500 ppm (high isoflavone intake; HI). Learning ability was evaluated by a Y-shaped water maze and the activity of acetylcholinesterase in brain was assayed after decapitation. Food intake and body weights as well as weights of brain, liver, spleen, heart and kidney showed no significant difference among the four groups, which means 500 ppm of isoflavones is safe. In the water maze test, the frequency of error counted when rats entered one end of the alley without platform was significantly lower in the HI group than in the control group, and the escape latency as swim time taken to escape on the hidden platform was significantly shorter in the HI group than in the LI and control groups. The activity of acetylcholinesterase of the brain was significantly higher in the HI and MI groups than in the control group. Therefore, the results indicate that isoflavones may improve the cognitive function without adverse effects.

Self-terminated carbonation model as an useful support for durable concrete structure designing

  • Woyciechowski, Piotr P.;Sokolowska, Joanna J.
    • Structural Engineering and Mechanics
    • /
    • 제63권1호
    • /
    • pp.55-64
    • /
    • 2017
  • The paper concerns concrete carbonation, the phenomena that occurs in every type of climate, especially in urban-industrial areas. In European Standards, including Eurocode (EC) for concrete structures the demanded durability of construction located in the conditions of the carbonation threat is mainly assured by the selection of suitable thickness of reinforcement cover. According to EC0 and EC2, the thickness of the cover in the particular class of exposure depends on the structural class/category and concrete compressive strength class which is determined by cement content and water-cement ratio (thus the quantitative composition) but it is not differentiated for various cements, nor additives (i.e., qualitative composition), nor technological types of concrete. As a consequence the selected thickness of concrete cover is in fact a far estimation - sometimes too exaggerated (too safe or too risky). The paper presents the elaborated "self-terminated carbonation model" that includes abovementioned factors and enables to indicate the maximal possible depth of carbonation. This is possible because presented model is a hyperbolic function of carbonation depth in time (the other models published in the literature use the parabolic function that theoretically assume the infinite increase of carbonation depth value). The paper discusses the presented model in comparison to other models published in the literature, moreover it contains the algorithm of concrete cover design with use of the model as well as an example of calculation of the cover thickness.