• 제목/요약/키워드: function generator

검색결과 702건 처리시간 0.031초

수치제어장치에 관한 연구 (Development of Numerical Controller Using PC and KM 3701 Function Generator LSI)

  • 이승영;박찬일
    • 한국기계연구소 소보
    • /
    • 통권15호
    • /
    • pp.105-115
    • /
    • 1985
  • For the application of factory automation, a 3-axis numerical control system with personal computer and KM3701 function generator LSI chip, which has liner, circular, parabolic, logarithmic, and exponential interpolations, is developed. The developed system also has 2 control function to stabilize tooling speed and 1/1000mm step sizes.

  • PDF

퍼지 소속 함수에 기초한 원전 증기발생기 검사용 실시간 비젼시스템 (Real Time Vision System for the Test of Steam Generator in Nuclear Power Plants Based on Fuzzy Membership Function)

  • 왕한흥
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 추계학술대회 논문
    • /
    • pp.107-112
    • /
    • 1996
  • In this paper it is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the preposed vision system, Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF

공작기계의 고장원인을 효과적으로 생성하기 위한 Switching Function Generator 개발 (Development of Switching Function Generator for Fault Reasons of CNC Machine Tool)

  • 김동훈;김도연;김선호;이은애;한기상
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.48-52
    • /
    • 2002
  • The fault analysis of the CNC machine tool which is controlled sequentially by PLC is generally based on ladder diagram. When machine tool has faults, it takes a lot of operator's experiences and times to identify logical relationship because ladder diagram is a step structured language. Therefore the technologies of finding out fault reasons automatically is necessary. In this paper, the SFG(Switching Function Generator) system is developed to analysis fault reasons correctly. The SF(Switching Function) and SSF(Step Switching Function) generated from SFG based on ladder diagram are experimented to identify the performance of SFG.

  • PDF

방사선발생장치 교육을 위한 시뮬레이터의 개발과 유용성 평가 (Development and Usefulness Evaluation of Simulator for Educational Radiation Generator)

  • 서정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.591-597
    • /
    • 2021
  • In the present study, we developed virtual reality education contents for radiation generator on radiation education field. The radiation generator was divided by module and even the X-ray exposure part was manufactured in detail for designing 3D models. The mechanical details of the X-ray exposure part, the function of adjusting field size of the X-ray, the function of moving the exposure part, and the demonstrating the principle of the X-ray tube were applied. For developing VR contents, the Unreal Engine was used. To evaluate the usefulness of virtual reality content, we used t-test by SPSS. The group used the simulator showed significantly higher levels of understanding of X-ray generation, X-ray irradiation unit composition, irradiation field size adjustment, irradiation unit position adjustment, and overall composition and function. We believe that this VR contents will be used well with radiation safe environment.

64채널 신호발생/분석 모듈 구현에 관한 연구 (A Study on Implementation of a 64 Channel Signal Generator / Analyzer Module)

  • 민경일;정갑천;최종현;박성모
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2609-2612
    • /
    • 2003
  • This paper describes a 64 channel signal generator/analyzer module that is useful for verification and testing of digital circuits. It can perform logic analyzer function and signal generator function at the same time. The 64 Channel module is implemented with single FPGA chip for miniaturization, and an USB interface is used to increase portability of the module. Multiple modules can be used in parallel for the verification of large scale circuits. Moreover, since the module is implemented as a PC based system, one can configure convenient GUI(Graphic User Interface) environment.

  • PDF

퍼지다목적함수를 이용한 발전기보수유지계획의 수립 (The Generator Maintenance Scheduling using Fuzzy Multi-criteria)

  • 최재석;도대호;이태인
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1995년도 추계학술대회 학술발표 논문집
    • /
    • pp.131-138
    • /
    • 1995
  • A new technique using integer programming based on fuzzy multi-criteria function is proposed for generator maintenance scheduling. Minimization maintenance delay cost and maximization reserve power are considered for fuzzy multi-criteria function. To obtain an optimal solution for generator maintenance scheduling under fuzzy environment, fuzzy multi-criteria integer programming is used. In the maintenance scheduling, a characteristic feature of the presented approach is that the crisp constraints with uncertainty can be taken into account by using fuzzy set theory and so more flexible solution can be obtained. The effectiveness of the proposed approach is demonstrated by the simulation results.

  • PDF

초기조건과 비선형 함수와의 상관관계를 이용한 스트림 암호시스템 분석 (Analysis of stream cipher system with initial condition and nonlinear function)

  • 김지홍;이만영
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.8-14
    • /
    • 1996
  • Key stream generator consisting of several linear feedback shift registers with a nonlinear combining function have been applied in stream cipher system. Most of the papers until now have been focusing on correlation atack and analysis of key stream generator with nonlinear combining function. Given some part of key stream sequences. We can generate identical output sequences with original key stream sequences if the feedback connection and the maximum order of nonlinear combination function are known.

  • PDF

Emergency Brushless Synchronous Generator Having Rotating Exciter Status Monitoring and Protection Functions

  • Oh, Yongseung;Oh, Wonseok;Cho, Kyumin
    • 한국정보기술학회 영문논문지
    • /
    • 제10권2호
    • /
    • pp.1-13
    • /
    • 2020
  • This paper presents an emergency brushless synchronous generator having rotating exciter status monitoring and protection functions. For monitoring the rotating exciter status, a wireless rotor status detector and a digital AVR(Automatic Voltage Regulator), which has a wireless communication capability, are proposed. The proposed rotor status detector detects temperatures of exciter armature and main field windings and input voltage and current of the main field. Therefore, it is possible to protect the generator from the over-temperature of windings and detect the exciter bridge diode fault. Furthermore, the proposed digital AVR has rotor status monitoring and protection function, and remote generator tuning, wireless group parallel operation function. So the operator can efficiently operate the generator using a smartphone from a remote area.

신재생에너지 발전원을 고려한 발전기 예방정비계획수립에 관한 연구 (A Study on Generator Maintenance Scheduling Considering Renewable Energy Generators)

  • 이연찬;오웅진;최재석;정명훈
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.601-610
    • /
    • 2018
  • The purpose of this paper is to establish a new optimum Generator Maintenance Scheduling(GMS) considering renewable energy generator. In this paper, the total renewable energy generation is estimated using hourly capacity factor of renewable energy generator. The GMS was optimized with the objective function of maximizing the minimum reserve rate, minimizing the probabilistic production cost, minimizing the loss of load expectation, and minimizing $CO_2$ emissions. In the case study of this paper, GMS considering renewable energy and GMS not considering renewable energy are shown by each objective function. And it shows scenarios of the reliability, the environmental and economical factors when two nuclear power plants inputted and ten coal thermal power plants shut downed respectively.

이용율과 혼소율을 이용한 발전기의 입출력 특성식 산정 (Calculation of the generator cost functions using the utilization factor of generators and the mixed fuel burning ratio of the generators)

  • 송경빈;남재현;박시우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1270-1272
    • /
    • 1999
  • The generator cost function is one of the basic data for the generation scheduling. Generally the cost functions are obtained form design calculations or from heat rate tests. The real operating condition may be different from the condition of design or the tests. Some of the conditions may not be tested during the periodical maintenance. In order to improve the calculation of the generator cost function, this paper presents a new calculation method of the generator cost functions using the utilization factors of generators and the mixed fuel burning ratio of the generators.

  • PDF