• 제목/요약/키워드: full-scale monitoring

검색결과 134건 처리시간 0.02초

Development of Acoustic Emission Monitoring System for Fault Detection of Thermal Reduction Reactor

  • Pakk, Gee-Young;Yoon, Ji-Sup;Park, Byung-Suk;Hong, Dong-Hee;Kim, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.25-34
    • /
    • 2003
  • The research on the development of the fault monitoring system for the thermal reduction reactor has been performed preliminarily in order to support the successful operation of the thermal reduction reactor. The final task of the development of the fault monitoring system is to assure the integrity of the thermal$_3$ reduction reactor by the acoustic emission (AE) method. The objectives of this paper are to identify and characterize the fault-induced signals for the discrimination of the various AE signals acquired during the reactor operation. The AE data acquisition and analysis system was constructed and applied to the fault monitoring of the small- scale reduction reactor, Through the series of experiments, the various signals such as background noise, operating signals, and fault-induced signals were measured and their characteristics were identified, which will be used in the signal discrimination for further application to full-scale thermal reduction reactor.

MODELING AND MULTIRESOLUTION ANALYSIS IN A FULL-SCALE INDUSTRIAL PLANT

  • Yoo, Chang-Kyoo;Son, Hong-Rok;Lee, In-Beum
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.88-103
    • /
    • 2005
  • In this paper, data-driven modeling and multiresolution analysis (MRA) are applied for a full-scale wastewater treatment plant (WWTP). The proposed method is based on modeling by partial least squares (PLS) and multiscale monitoring by a generic dissimilarity measure (GDM), which is suitable for nonstationary and non-normal process monitoring such as a biological process. Case study in an industrial plant showed that the PLS model could give good modeling performance and analyze the dynamics of a complex plant and MRA was useful to detect and isolate various faults due to its multiscale nature. The proposed method enables us to show the underlying phenomena as well as to filter out unwanted and disturbing phenomena.

Practical Experience with Full-scale Performance Verification of Dynamic Vibration Absorbers installed in Tall Buildings

  • Love, J.S.;Morava, B.
    • 국제초고층학회논문집
    • /
    • 제10권2호
    • /
    • pp.85-92
    • /
    • 2021
  • Dynamic vibration absorbers (DVAs) in the form of tuned sloshing dampers (TSDs) and tuned mass dampers (TMDs) are commonly used to reduce the wind-induced motion of high-rise buildings. Full-scale performance of structure-DVA systems must be evaluated during the DVA commissioning process using structural monitoring data. While the random decrement technique (RDT) is sometimes employed to evaluate the DVA performance, it is shown to have no theoretical justification for application to structure-DVA systems, and to produce erroneous results. Subsequently, several practical methods with a sound theoretical basis are presented and illustrated using simulated and real-world data. By monitoring the responses of the structure and DVA simultaneously, it is possible to directly measure the effective damping of the system or perform system identification from which the DVA performance can be evaluated.

프리캐스트 패널의 양중에 따른 거동 계측 연구 (Behavior Monitoring of Precast Concrete Panels in Lifting)

  • 양성철;김성민;한승환;윤상천
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권3호
    • /
    • pp.51-59
    • /
    • 2012
  • 본 연구에서는 도로용 패널로 사용되는 프리캐스트 콘크리트 슬래브의 양중, 이동 및 설치 등 제품의 제작 및 시공 시 발생될 수 있는 양중에 따른 안전 설계요소를 분석하였다. 그 결과를 토대로 축소형 슬래브(Full-scale용 슬래브의 1/2 크기 규모로 $1.8m{\times}3m{\times}0.15m$) 2개와 Full-scale용 슬래브($3.9m{\times}5.95m{\times}0.29m$) 1개를 제작하였으며, 콘크리트 및 철근 게이지를 설치하여 슬래브의 양중 및 트럭에 적재하여 이동 시 급작스런 동적거동으로 인해 발생되는 콘크리트 슬래브의 변형률을 측정하였다. 축소형 슬래브의 경우 60도로 양중 시 정지상태의 변형률에 비해 약 3.54배의 변형률에 도달하였다. 그러나 Full-scale용 슬래브는 양중 및 운반 중의 동적 거동을 계측한 결과 동적변형률이 그리 크지는 않아 양중과 운반 시에 파손될 염려는 거의 없는 것으로 판단되어 본 연구에서 채택한 양중 시스템의 안전성을 확인하였다.

Full-scale investigation of wind-induced vibrations of a mast-arm traffic signal structure

  • Riedman, Michelle;Sinh, Hung Nguyen;Letchford, Christopher;O'Rourke, Michael
    • Wind and Structures
    • /
    • 제20권3호
    • /
    • pp.405-422
    • /
    • 2015
  • In previous model- and full-scale studies, high-amplitude vertical vibrations of mast-arm traffic signal structures have been shown to be due to vortex shedding, a phenomenon in which alternatingly shed, low-pressure vortices induce oscillating forces onto the mast-arm causing a cross-wind response. When the frequency of vortices being shed from the mast-arm corresponds to the natural frequency of the structure, a resonant condition is created causing long-lasting, high-amplitude vibrations which may lead to the fatigue failure of these structures. Turbulence in the approach flow is known to affect the cohesiveness of vortex shedding. Results from this full-scale investigation indicate that the surrounding terrain conditions, which affect the turbulence intensity of the wind, greatly influence the likelihood of occurrence of long-lasting, high-amplitude vibrations and also impact whether reduced service life due to fatigue is likely to be of concern.

SHM benchmark for high-rise structures: a reduced-order finite element model and field measurement data

  • Ni, Y.Q.;Xia, Y.;Lin, W.;Chen, W.H.;Ko, J.M.
    • Smart Structures and Systems
    • /
    • 제10권4_5호
    • /
    • pp.411-426
    • /
    • 2012
  • The Canton Tower (formerly named Guangzhou New TV Tower) of 610 m high has been instrumented with a long-term structural health monitoring (SHM) system consisting of over 700 sensors of sixteen types. Under the auspices of the Asian-Pacific Network of Centers for Research in Smart Structures Technology (ANCRiSST), an SHM benchmark problem for high-rise structures has been developed by taking the instrumented Canton Tower as a host structure. This benchmark problem aims to provide an international platform for direct comparison of various SHM-related methodologies and algorithms with the use of real-world monitoring data from a large-scale structure, and to narrow the gap that currently exists between the research and the practice of SHM. This paper first briefs the SHM system deployed on the Canton Tower, and the development of an elaborate three-dimensional (3D) full-scale finite element model (FEM) and the validation of the model using the measured modal data of the structure. In succession comes the formulation of an equivalent reduced-order FEM which is developed specifically for the benchmark study. The reduced-order FEM, which comprises 37 beam elements and a total of 185 degrees-of-freedom (DOFs), has been elaborately tuned to coincide well with the full-scale FEM in terms of both modal frequencies and mode shapes. The field measurement data (including those obtained from 20 accelerometers, one anemometer and one temperature sensor) from the Canton Tower, which are available for the benchmark study, are subsequently presented together with a description of the sensor deployment locations and the sensor specifications.

Damage detection on a full-scale highway sign structure with a distributed wireless sensor network

  • Sun, Zhuoxiong;Krishnan, Sriram;Hackmann, Greg;Yan, Guirong;Dyke, Shirley J.;Lu, Chenyang;Irfanoglu, Ayhan
    • Smart Structures and Systems
    • /
    • 제16권1호
    • /
    • pp.223-242
    • /
    • 2015
  • Wireless sensor networks (WSNs) have emerged as a novel solution to many of the challenges of structural health monitoring (SHM) in civil engineering structures. While research projects using WSNs are ongoing worldwide, implementations of WSNs on full-scale structures are limited. In this study, a WSN is deployed on a full-scale 17.3m-long, 11-bay highway sign support structure to investigate the ability to use vibration response data to detect damage induced in the structure. A multi-level damage detection strategy is employed for this structure: the Angle-between-String-and-Horizon (ASH) flexibility-based algorithm as the Level I and the Axial Strain (AS) flexibility-based algorithm as the Level II. For the proposed multi-level damage detection strategy, a coarse resolution Level I damage detection will be conducted first to detect the damaged region(s). Subsequently, a fine resolution Level II damage detection will be conducted in the damaged region(s) to locate the damaged element(s). Several damage cases are created on the full-scale highway sign support structure to validate the multi-level detection strategy. The multi-level damage detection strategy is shown to be successful in detecting damage in the structure in these cases.

Wind-induced response and loads for the Confederation Bridge -Part I: on-site monitoring data

  • Bakht, Bilal;King, J. Peter C.;Bartlett, F.M.
    • Wind and Structures
    • /
    • 제16권4호
    • /
    • pp.373-391
    • /
    • 2013
  • This is the first of two companion papers that analyse ten years of on-site monitoring data for the Confederation Bridge to determine the validity of the original wind speeds and wind loads predicted in 1994 when the bridge was being designed. The check of the original design values is warranted because the design wind speed at the middle of Northumberland Strait was derived from data collected at shore-based weather stations, and the design wind loads were based on tests of section and full-aeroelastic models in the wind tunnel. This first paper uses wind, tilt, and acceleration monitoring data to determine the static and dynamic responses of the bridge, which are then used in the second paper to derive the static and dynamic wind loads. It is shown that the design ten-minute mean wind speed with a 100-year return period is 1.5% less than the 1994 design value, and that the bridge has been subjected to this design event once on November 7, 2001. The dynamic characteristics of the instrumented spans of the bridge including frequencies, mode shapes and damping are in good agreement with published values reported by others. The on-site monitoring data show bridge response to be that of turbulent buffeting which is consistent with the response predicted at the design stage.

Structural Health Monitoring System of Long-Span Bridges in Korea

  • Chang, Sung-Pil
    • Corrosion Science and Technology
    • /
    • 제3권2호
    • /
    • pp.39-46
    • /
    • 2004
  • Development and application of structural health monitoring system in Korea have become active since the early 1990's. In earlier applications, health monitoring systems were installed in several existing bridges in order to collect initial field data by full scale load capacity test for design verification and subsequently monitor long-term performance and durability of the bridge as part of an inspection and maintenance program. Recently, modem and integrated monitoring systems have been introduced in most of the newly constructed long-span bridges since the design stage. This paper outlines the progresses and applications of monitoring systems in Korea for both existing and newly constructed bridges and describes their aims and characteristics.

가속도 응답을 이용한 실물 콘크리트 거더 교량의 구조건전성 모니터링 (Structural Health Monitoring of Full-Scale Concrete Girder Bridge Using Acceleration Response)

  • 홍동수;김정태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.165-174
    • /
    • 2010
  • 본 논문에서는 실물 콘크리트 거더 교량의 가속도 응답 신호를 이용하여 구조물의 상태변화를 경보한 후 그 위치 변화를 검색하는 2단계 구조건전성 모니터링 체계를 제시하였다. 먼저, 2경간 연속 콘크리트 거더 교량인 미호천교를 대상교량으로 선정하였으며, 볼링공을 이용한 강제진동 실험으로부터 동특성을 추출하였다. 다음으로, 미호천교의 2단계 구조건전성 모니터링 체계 구축을 위한 손상 발생 경보 및 손상 위치 검색 기법들을 선정하였다. 손상 경보 기법으로는 시간영역 특징을 이용하는 자기회귀모델과 주파수응답함수의 상관계수, 주파수응답비보증지수를 선정하였다. 손상 위치 검색 기법으로는 모드변형에너지기반 손상지수법을 선정하였다. 마지막으로, 덤프트럭을 이용한 정적 재하 실험을 통해 2단계 손상 모니터링 체계의 적합성을 검증하였다.