• Title/Summary/Keyword: full-information

Search Result 3,671, Processing Time 0.029 seconds

Development of Strain-gauge-type Rotational Tool Dynamometer and Verification of 3-axis Static Load (스트레인게이지 타입 회전형 공구동력계 개발과 3축 정적 하중 검증)

  • Lee, Dong-Seop;Kim, In-Su;Lee, Se-Han;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.72-80
    • /
    • 2019
  • In this task, the tool dynamometer design and manufacture, and the Ansys S/W structural analysis program for tool attachment that satisfies the cutting force measurement requirements of the tool dynamometer system are used to determine the cutting force generated by metal cutting using 3-axis static structural analysis and the LabVIEW system. The cutting power in a cutting process using a milling tool for processing metals provides useful information for understanding the processing, optimization, tool status monitoring, and tool design. Thus, various methods of measuring cutting power have been proposed. The device consists of a strain-gauge-based sensor fitted to a new design force sensing element, which is then placed in a force reduction. The force-sensing element is designed as a symmetrical cross beam with four arms of a rectangular parallel line. Furthermore, data duplication is eliminated by the appropriate setting the strain gauge attachment position and the construction of a suitable Wheatstone full-bridge circuit. This device is intended for use with rotating spindles such as milling tools. Verification and machining tests were performed to determine the static and dynamic characteristics of the tool dynamometer. The verification tests were performed by analyzing the difference between strain data measured by weight and that derived by theoretical calculations. Processing test was performed by attaching a tool dynamometer to the MCT to analyze data generated by the measuring equipment during machining. To maintain high productivity and precision, the system monitors and suppresses process disturbances such as chatter vibration, imbalances, overload, collision, forced vibration due to tool failure, and excessive tool wear; additionally, a tool dynamometer with a high signal-to-noise ratio is provided.

The Mediating Effect of Emotional Clarity and Ambivalence over Emotional Expressiveness in the Relationship between College Student's Covert Narcissism and Depression (대학생의 내현적 자기애가 우울에 미치는 영향: 정서인식 명확성과 정서표현 양가성의 매개효과)

  • Yu, Hyeon-A;Song, Wonyoung
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.3
    • /
    • pp.161-168
    • /
    • 2018
  • This study examined the relationship between covert narcissism on depression for College students as a mediator Emotional Clarity and Ambivalence over Emotional Expressiveness through structural equation modeling. To this end, we conducted a survey of 343 university students living in central area of Korea, a measure of CNS, BDI, TMMS, AEQ-K. The result of the study were as follows. First, all the variables had meaningful positive of negative correlations. Secondly, When Covert Narcissism affects Depression, Emotional Clarity and Ambivalence over emotional expressiveness were full mediated. Third, the indirect effects of Emotional Clarity, Ambivalence over Emotional Expressiveness on the effects of covert narcissism on depression were relevance. Finally, the implications and limitations of the study were discussed.

Systemic Review of Pramlintide, a New Drug for the Treatment of Diabetes Mellitus (새로운 당뇨병 치료제 Pramlintide의 Systematic Review)

  • Shanmugam, Srinivasan;Jung, Hee-Yong;Yong, Chul-Soon;Choi, Han-Gon;Kim, Jung-Ae;Yoo, Bong-Kyu
    • YAKHAK HOEJI
    • /
    • v.50 no.6
    • /
    • pp.386-392
    • /
    • 2006
  • Pramlintide, a synthetic analogue of human hormone amylin, is the first of a new class of amylinomimetic compounds. Present study was undertaken to compile and analyze the clinical trials of pramlintide, and thereby to facilitate the design of the bridging study for the earlier introduction of the drug, which might be needed by diabetes patients in Korea. Sixty-two articles from Pubmed and MEDLINE search were used to analyze the trials of pramlintide along with prescribing information and New Drug Application packet obtained form the manufacturer. The efficacy of the new drug was attributed to three mechanisms: delay of gastric emptying time, inhibition of post-prandial glucagon secretion, and reduction of food intake by enhanced satiety. Clinical trials consistently identified the effectiveness of the drug for the treatment of type 1and type 2 diabetes who have failed to achieve glycemic control despite optimal therapy with insulin. However, the six pivotal Phase III clinical trials were peformed with mostly caucasian and some black and hispanic people. None of the trials documented the proportion of either Asian or Korean participants. Since Korean diabetes patients show different epidemiology and characteristics in their disease state, it appears that the bridging study of pramlintide should be designed in the level of full scale Phase III clinical trial along with pharmacokinetic and pbarmacodynamic studies.

A rock mass assessment procedure based on quantitative geophysical log analysis of coal measure sequences (탄층에 대한 정량적 물리검층에 기초한 암반 평가 과정)

  • Hatherly Peter;Medhurst Terry;Sliwa Renate;Turner Roland
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.112-117
    • /
    • 2005
  • Geophysical logging is routinely undertaken as part of most coal mine exploration programs. Currently, the main application for the logs is to determine coal seam depth and to qualitatively estimate coal quality, lithology, and rock strength. However, further information can be obtained, if quantitative log interpretation is made. To assist in the uptake of quantitative interpretation, we discuss log responses in terms of the mineralogy of the clastic sedimentary rocks frequently found in the Australian black coal mining areas of the Sydney and Bowen Basins. We find that the log responses can be tied to the mineralogy with reasonable confidence. Ambiguities in the interpretation will be better resolved if a full suite of logs is run. A method for checking for internal consistency, by comparing calculated and observed velocities, is also described. A key driver for quantitative interpretation is geotechnical characterisation. We propose a classification system for clastic rocks that takes into consideration physical rock properties that can be inferred from geophysical logs.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

One Year of GOCI-II Launch Present and Future (GOCI-II 발사 1년, 현재와 미래)

  • Choi, Jong-kuk;Park, Myung-sook;Han, Kyung-soo;Kim, Hyun-cheol;Im, Jungho
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1229-1234
    • /
    • 2021
  • GOCI-II, which succeeded the mission of GOCI, was successfully launched in February 2020 and is in operation. GOCI-II is expected to be highly useful in a wide range of fields, including detailed changes in the coastal seawater environment using improved spatial and spectral resolution, increased number of observation and full disk observation mode. This special issue introduces the assessment of the current GOCI-II data quality and the studies on the accuracy improvement and applications at this time of one year after launch and data disclosure. We expect that this issue can be an opportunity for GOCI-II data to be actively utilized not only in the ocean but also in various fields of land and atmosphere.

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

Analysis of behavioral management for dental treatment in patients with dementia using the Korean National Health Insurance data

  • Kim, Taeksu;Chi, Seong In;Kim, Hyuk;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.5
    • /
    • pp.461-469
    • /
    • 2021
  • Background: The global population is aging rapidly, and accordingly, the number of patients with dementia is increasing every year. Although the need for dental treatment increases for various reasons in patients with dementia, they cannot cooperate during dental treatment. Therefore, behavioral management, including sedation (SED) or general anesthesia (GA), is required for patients with dementia. Thus, this study aimed to investigate the trends and effects of SED or GA in patients with dementia undergoing dental treatment in South Korea based on the Korean National Health Insurance claims data. Methods: This study utilized customized health information data provided by the Health Insurance Review and Assessment Service. Among patients with records of using sedative drugs during dental treatment from January 2007 to September 2019, patients with the International Classification of Diseases-10 code for dementia (F00, F01, F02, F03, and G30) were selected. We then analyzed the full insurance claims data for dental care. Age, sex, sedative use, and dental treatment of patients were analyzed yearly. In addition, the number of cases of GA or SED per year was analyzed, and changes in behavioral management methods with increasing age were investigated. Results: Between January 2007 and September 2019, a total of 4,383 (male, 1,454; female, 2,929) patients with dementia received dental treatment under SED or GA. The total number of SED and GA cases were 1,515 (male, 528 ; female, 987 ) and 3,396 (male, 1,119 ; female, 2,277) cases, respectively. The total number of cases of dental treatment for 4,383 patients with dementia was 153,051 cases, of which 2.22% were under GA and 0.98% were under SED. Midazolam was the most commonly used drug for SED. Conclusion: Although gingivitis and pulpitis were the most common reasons for patients with dementia to visit the dentist, GA or SED for patients with dementia was frequently used in oral and maxillofacial or periodontal surgery.

FRS-OCC: Face Recognition System for Surveillance Based on Occlusion Invariant Technique

  • Abbas, Qaisar
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.8
    • /
    • pp.288-296
    • /
    • 2021
  • Automated face recognition in a runtime environment is gaining more and more important in the fields of surveillance and urban security. This is a difficult task keeping in mind the constantly volatile image landscape with varying features and attributes. For a system to be beneficial in industrial settings, it is pertinent that its efficiency isn't compromised when running on roads, intersections, and busy streets. However, recognition in such uncontrolled circumstances is a major problem in real-life applications. In this paper, the main problem of face recognition in which full face is not visible (Occlusion). This is a common occurrence as any person can change his features by wearing a scarf, sunglass or by merely growing a mustache or beard. Such types of discrepancies in facial appearance are frequently stumbled upon in an uncontrolled circumstance and possibly will be a reason to the security systems which are based upon face recognition. These types of variations are very common in a real-life environment. It has been analyzed that it has been studied less in literature but now researchers have a major focus on this type of variation. Existing state-of-the-art techniques suffer from several limitations. Most significant amongst them are low level of usability and poor response time in case of any calamity. In this paper, an improved face recognition system is developed to solve the problem of occlusion known as FRS-OCC. To build the FRS-OCC system, the color and texture features are used and then an incremental learning algorithm (Learn++) to select more informative features. Afterward, the trained stack-based autoencoder (SAE) deep learning algorithm is used to recognize a human face. Overall, the FRS-OCC system is used to introduce such algorithms which enhance the response time to guarantee a benchmark quality of service in any situation. To test and evaluate the performance of the proposed FRS-OCC system, the AR face dataset is utilized. On average, the FRS-OCC system is outperformed and achieved SE of 98.82%, SP of 98.49%, AC of 98.76% and AUC of 0.9995 compared to other state-of-the-art methods. The obtained results indicate that the FRS-OCC system can be used in any surveillance application.

Status and Perspectives of Preplacement Health Examination (PHE) at Certain Workplaces (일부 사업장에서 나타난 배치전건강진단 제도 현황과 향후과제)

  • Park, Hyesook;Kang, Seong-Kyu;Lee, Wanhyung;Choi, Won-Jun;Ham, Seunghon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.540-548
    • /
    • 2021
  • Introduction: Preplacement health examination (PHE) is performed when a worker starts a certain work task which is designated as having occupational risks by the Ministry of Employment and Labor (MOEL). All data related to health examination except PHE are reported to the MOEL by the law. This study has been performed to understand the status of PHE at certain workplaces. Methods: PHE data gathered in a university hospital were analyzed and they were followed with results of the special health examination (SHE) in 2019 and 2020. Those who were evaluated as unfit to work as it was, were interviewed directly or indirectly through an occupational health manager to follow up the management status of their recognized health problems. Results: The unfit to work (unFTW) rate of PHE was 2.8%, and was not different according to the size of workplace or having occupational health service. The major cause of unfit to work was the uncontrolled life-style diseases such as hypertension and diabetes. The rate of SHE followed by PHE was 31.1%. It was not different by the unFTW rates, however, they were different according to having a full time in-house occupational health manager. Thirty-one among 71 examinees who were evaluated as unFTW underwent SHE after controlling their health condition and were finally evaluated as fit to work. Nineteen among 31 started to take medicine and eight have been placed in the work without designated risks. Conclusion: PHE can be used for new workers, who may have unknown or uncontrolled life-style diseases, to be asked to manage life-style diseases as well as work-related risks such as shift work. In order to have a better tracking system for work-related risks, the information of PHE should be analyzed together with other data from health examination.