• Title/Summary/Keyword: full ratio

Search Result 1,285, Processing Time 0.029 seconds

Effect of Low Lactose Special Formula (MF-1) for the Treatment of Acute Diarrhea in Infants (유아의 급성 설사 치료에 있어서의 저유당 조제 분유의 효과)

  • Kwon, Oh-Hyouk;Kim, Sang-Duk;Kim, Kyeung-A;Shin, Son-Moon
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.251-260
    • /
    • 1996
  • To evaluate the effect of low lactose special formula (MF-1) for the treatment of acute diarrhea, we studied thirty nine infants who were admitted with acute diarrhea to the Department of Pediatics, Yeungnam University Hospital. 39 infants of under 6 months of age who had been fed on formula feeds were randomly allocated to receive either a diluted regular formula milk or a low lactose special formula. Each infant received intravenous rehydration during fasting for 6-12 hours. Group 1 (n=15) was fed half strength of regular formula (80-100cc/kg/day) for the first 24 hours, three quarters strength formula (100-120cc/kg/day) for the next 24 hours, and continued feeding with the full strength regular formula milk. Group 2 (n=24), who fed the same amount of milk as Group 1, continued feeding with the full strength low lactose special formula from the start of feeding. Male to female sex ratio was 1.6 to 1. The characteristics of infants on admission were comparable in the age, the duration of diarrhea and the stool frequency before admission, the degree of dehydration. There were no significant differences in the duration of hospitalization, changes in stool weight and stool frequency after admission between two groups.(p>0.05) The Body weight and skin fold thickness were increased in group 2 who fed low lactose formula, but those who fed diluted regular formula showed reduction of body weight and skin fold thickness ($64.2{\pm}51.4g$ vs $-11.4{\pm}52.2g$, $0.6{\pm}0.8mm$ vs $-0.1{\pm}0.3mm$ respectively) during hospitalization. (p<0.05) We conclude that low lactose special formula milk can be recommended instead of diluted regular formula for acute diarrhea treatment in infants.

  • PDF

A weld-distortion analysis method of the shell structures using ultra structural FE model (초대형 구조모델을 활용한 쉘구조물의 용접변형 해석)

  • Ha, Yunsok;Yi, Myungsu
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.62-67
    • /
    • 2015
  • A very large shell-structure built in shipyards like ship hulls or offshore structures are joined by welding through full process. As the welding contains a high thermal cycle at a local area, the welded structures should be distorted unavoidably. Because a distorted ship block should be revised to the designed value before the next stage, the ability to predict and to control the weld distortion is an accuracy level of the yard itself. Despite the ship block size, several present thermal distortion methodologies can deal those sizes, but it is a different story to deal full ship size model. Even a fully constructed ship hull not remaining any welding can have an accuracy issue like outfitting installation problems. Any present thermal distortion methodology cannot accept this size for its recommended element size and the number. The ordinary welding breadth at erection stage is about 20~40 mm. It can hardly be a good choice to make finite element model of these sizes considering human effort and computational environment. The finite element model for structure analysis of a ship hull is prepared at front-end engineering design stage which is the first process of the project. The element size of the model is as fine as the longitudinal space, and it is not proper to obtain a weld distortion at the erection stage. In this study, a methodology is suggested that a weldment can be shrunk at original place instead of using structural finite element model. We cut the original shell elements at erection weld-line and put truss elements between the edges of cut elements for weld shrinkage. Additional truss elements are used to facsimile transverse weld shrinkage which cannot be from the weld-line truss element shrink. They attach to weld-line truss element like twigs from barks. The capacity of developed elements is verified through an accuracy check of erection process of a container vessel at the apt. hull. It can be a useful tool for verifying a centering accuracy after renew and for block-separating planning considering accuracy.

Evaluation on the Shear Performance of U-type Precast Prestressed Beams (U형 PSC보외 전단거동 평가)

  • Yu Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.10-17
    • /
    • 2004
  • Shear tests were performed on four ends of full scale U-type beams which were designed by optimum process for the depth with a live load of 4903Pa. The ratio of width to depth of full scale 10.5 m-span, composite U-type beams with topping concrete was greater than 2. Following conclusions were obtained from the evaluation on the shear performance of these precast prestressed beams. 1) Those composite U-type beams performed homogeneously up to the failure load, and conformed to ACI Strength design methods in shear and flexural behaviors. 2) The anchorage requirements on development length of strand In the ACI Provisions preyed to be a standard to determine a failure pattern within the limited test results of the shallow U-type beams. 3) Those all shear crackings developed from the end of the beams did not lead to anchorage failure. However, initiated strand slip may leads the bond failure by increasing the size of diagonal shear crackings. 4) The flexural mild reinforcement around the vertical center of beam section was effective for developments of a ductile failure.

Organic-layer and semitransparent electrode thickness dependent optical properties of top-emission organic light-emitting diodes (전면 유기 발광 소자의 유기물층과 반투명 전극의 두께 변화에 따른 광학적 특성)

  • An, Hui-Chul;Joo, Hyun-Woo;Na, Su-Hwan;Han, Wone-Keun;Kim, Tae-Wan;Lee, Won-Jea;Chung, Dong-Hoe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.57-58
    • /
    • 2008
  • We have studied an organic layer and semitransparent Al electrode thickness dependent optical properties and microcavity effects for top-emission organic light-emitting diodes. Manufactured top-emission device structure is Al(100nm)/TPD(xnm)/Alq(ynm)/LiF(0.5nm)/Al(25nm). While a thickness of total organic layer was varied from 85nm to 165n, a ratio of those two layers was kept to be about 2:3. Semitransparent Al cathode was varied from 20nm to 30nm for the device with an organic layer total thickness of 140nm. As the thickness of total organic layer increases, the emission spectra show a shift of peak wavelength from 490nm to 580nm, and the full width at half maxima from 90nm to 35nm. The emission spectra show a blue shift as the view angle increases. Emission spectra depending on a transmittance of semitransparent cathode show a shift of peak wavelength from 515nm to 593nm. At this time, the full width at half maximum was about to be a constant of 50nm. With this kind of microcavity effect, we were able to control the emission spectra from the top-emission organic light-emitting diodes.

  • PDF

A Dual-Scale Analysis of Macroscopic Resin Flow in Vacuum Assisted Resin Transfer Molding Process (VARTM공정에서의 거시적 수지 유동의 Dual-Scale 분석)

  • 박윤희;강문구;이우일
    • Composites Research
    • /
    • v.15 no.6
    • /
    • pp.1-7
    • /
    • 2002
  • In VARTM process where a sacrificial medium is used to facilitate the resin flow, the velocity of resin varies drastically between the sacrificial medium and the fiber preform. Although the thickness-to-length ratio of a VARTM product is usually small, a 3-D analysis is prerequisite to analyze the lead-lag flow in the two different media. The problem associated with the full 3-D analysis is the CPU time. A full 3-D numerical mesh comprising large number of nodes requires an impractical CPU time on average computer platforms. In this study, a dual-scale analysis technique was developed. The flow analysis for the entire calculation domain was conducted in 2.5-D, and the 3-D analysis was performed for a small area of special concern. In some numerical examples, the local 3-D analysis could discover an eccentric flow pattern as well as the lead-lag flow that will inevitably be neglected in 2.5-D simulations. The global-local analysis technique practiced in this study can be used to analyze the intricate flow of resin through non-uniform media in affordable CPU times.

Combustion Test of Regenerative Cooling Combustor for Liquid Rocket Engine (실물형 재생냉각 액체로켓엔진 연소기(확대비3.5) 연소시험)

  • Yang, Seung-Ho;Kim, Hee-Tea;Kang, Dong-Hyuk;Ahn, Kyu-Bok;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.125-130
    • /
    • 2007
  • Firing tests have been performed for a 30 tonf-class full-scale regeneratively cooled combustion chamber. It was the first model which has welded construction of the injection head and the combustion chamber. A number of firing tests have been performed to evaluate combustion efficiency, regenerative cooling performance and durability of the combustor. This paper describes the results of firing tests performed at the design and off-design conditions which correspond to the chamber pressure of 60 bar, 68 bar respectively and the O/F ratio of 2.5 and 2.8 respectively. The data at each test condition have provided successful results in terms of combustion performance, combustion stability and durability. The tests are considered to be quite meaningful in the sense that the technologies for kerosene regeneratively cooled combustion chamber are successfully proven.

  • PDF

Evaluation of quality indices during fruit development and ripening in 'Wonhwang' and 'Whasan' pears (동양배 '원황' 및 '화산'의 생육기간 중 품질 변화 요인 탐색)

  • Lee, Ug-Yong;Chun, Jong-Pil
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.405-411
    • /
    • 2011
  • In this study, we evaluated the changes of fruit quality indices during fruit development and ripening in Korean new pear cultivar 'Wonhwang' and 'Whasan' to determine appropriate harvest time and to enhance the marketability. The fruit of each cultivar harvested from 100 days after full bloom (DAFB) to 135 and 150 DAFB in 'Wonhwang' and 'Whasan', respectively. The fruit growth of both cultivars showed a typical single sigmoidal pattern. Flesh firmness of two cultivars decreased continuously with fruit development and ripening, reaching a final level of about 2.6 kgF at harvest stage. The starch content of fruit sap was much higher in the fruits of early development stage than the later stage of fruit ripening. In 'Wonhwang' pears, the starch level decreased coincide with fruit ripening (130 DAFB), while that of 'Whasan' decreased from very early stage of fruit development (120 DAFB), 30 days before full ripe. 'Whasan' pear showed much lower acidity level of about 0.13% during fruit development and ripening period compared with that of 'Wonhwang'. Therefore, the ratio of soluble solids to total acidity (TSS/acid) increased gradually with fruit development and ripening, reaching a final level of 80 and 98 in 'Wonhwang' and 'Whasan', respectively. There were no climateric rise of fruit respiration during fruit ripening periods in two oriental pear cultivar. The changes of skin color difference including hunter vale $a^*$ which means loss of green color occurred only after onset of ripening in two cultivars.

A Study on Radiographic Equipments and Situation for the Chest (흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査))

  • Ko, Shin-Gwan;An, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

Population Structure of Surface Swarms of the Euphausiid Euphausia pacifica Caught by Drum Screens of Uljin Nuclear Power Plant in the East Coast of Korea

  • Suh, Hae-Lip;Lim, Ju-Hwan;Soh, Ho-Young
    • Journal of the korean society of oceanography
    • /
    • v.33 no.1-2
    • /
    • pp.35-40
    • /
    • 1998
  • In February and April 1997, three temporary interruptions of electric power production at the Uljin Nuclear Power Plant in the east coast of Korea were caused by the malfunction of the cool-ing-water supply unit. The clogging of the drum screens inside the unit caused by the surface swarm of the euphausiid Euphausia pacifica Hansen might be responsible for the malfunction. These incidents were of particular interest since such interruption of reactors' operation by krill swarms had not previously been reported. Using samples caught by the drum screens inside the cooling water-supply unit, we investigated the population structure of surface swarms. One occasion of nighttime and three occasions of daytime surface swarms were found in February and April 1997, respectively. The foreguts of more than 60% of E. pacifica in nighttime surface swarm were in full condition. This evidence suggests that E. pacifica aggregates to the surface water at night for feeding. In daytime surface swarms consisting of mature E. pacifica, however, foreguts in full condition were only found in less than 10eio of krill examined, suggesting that daytime surface swarms are closely related to breeding activity. During the study period, the growth rate of mature females was more than twice higher than that of mature males. Analyses of the sex-ratio and length-frequency data show a decrease in the portion of males with increasing size. There was a decline in the number of males of 19 mm in length. Energy loss during spermatophore transfer may result in the death of male E. pacifica, as found in male E. superba.

  • PDF

Structural Behaviour of TEC-BEAM Connection with Steel Column Under Cyclic Loading (반복하중을 받는 TEC-BEAM 철골브라켓 접합부 거동평가)

  • Ju, Young Kyu;Kim, Ji Young;Kim, Myeong Han;Jung, Kwang Ryang;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2002
  • To reduce the story height for high-rise buildings, the TEC Beam is developed as a new composite beam composed of structural tee, precast concrete, stirrup, and site-in-cast reinforced concrete slab. The preliminary test of the proposed system was performed for simple beams and it showed a good behavior. However, for the field application of the system, it is required to develope a steel moment resisting connection using steel brackets on which upper rebars of the TEC BEAM are anchored. In this paper, three types of the proposed system are experimentally investigated. The parameters of the test are as follows: (1) the spacing of transverse bars, (2) the ratio of width of rebar's layer to bracket length. Specimens were classified as semi-rigid full strength by the Eurocode 4. It could be concluded that the proposed moment resisting system shows a good structural behavior and may be applicable in the filed.