• Title/Summary/Keyword: full ratio

Search Result 1,285, Processing Time 0.032 seconds

Evaluation and Identification of Promising Bivoltine Double Hybrids of the Silkworm Bombyx mori L. for Tropics Through Large Scale In-House Testing

  • Dayananda, Dayananda;Kulkarni, Satish;Rao, Pala Rama Mohana;Gopinath, Obalaiah;Kumar, Sundara Murthy Nirmal
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.23 no.2
    • /
    • pp.187-191
    • /
    • 2011
  • An attempt was made to assess the potentiality of bivoltine double hybrids under simulated conditions of farmers to identify the suitable bivoltine double hybrid combination. Four bivoltine double hybrids developed at Central Sericultural Research and Training Institute (CSRTI), Mysore along with popular single hybrid, $CSR2{\times}CSR4$ as control was assessed for economic traits. The rearing results showed significant improvement of 20-24% in fecundity of the double hybrids studied over single hybrid. Among the double hybrids, $[D7{\times}S5]{\times}[D13{\times}S1]$ recorded significantly higher survival (89.58 %), cocoon yield (76.328 kg/ 50,000 eggs), cocoon price (Rs. 180.87/kg) and lower cocoon leaf ratio of 1: 21.80. The performance of the reeling traits were also found significantly superior in $[D7{\times}S5]{\times}[D13{\times}S1]$ with higher filament length (1100 m), reelability (88%), raw silk (18.55%) and neatness (92 points) compared to $CSR2{\times}CSR4$ and other double hybrids evaluated. Besides, the cocoons of $[D7{\times}S5]{\times}[D13{\times}S1]$ exhibit uniformity in size with a standard deviation of < 8. Overall data indicated the superiority of $[D7{\times}S5]{\times}[D13{\times}S1]$ compared to the other hybrids evaluated and it has profound influence in expressing the full potentiality in the field.

Mechanical Characteristics of Retractable Radial Cable Roof Systems (개폐식 방사형 케이블 지붕 시스템의 역학적 특성)

  • Park, Kang-Geun;Lee, Dong-Woo;Choe, Dong-Il
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.21-32
    • /
    • 2017
  • The objective of this study is to analysis the mechanical characteristics on the geometric nonlinear behavior of radial cable roof systems for long span retractable cable roof structures. The retractable roof is designed as a full control system to overcome extreme outdoor environments such as extreme hot or cold weather, strong wind or sunlight, and the cable roof greatly can reduce roof weight compared to other rigid structural system. A retractable cable roof system is a type of structures in which the part of entire roof can be opened and closed. The radial cable roof is an effective structural system for large span retractable roofs, the outer perimeter of the roof is a fixed membrane roof and the middle part is a roof that can be opened and closed. The double arrangement cables of a radial cable truss roof system with reverse curvature works more effectively as a load bearing cables, the cable system can carry vertical load in up and downward direction. In this paper, to analyze the mechanical characteristics of a radial cable roof system with central posts, the authors will investigate the tensile forces of bearing cables, stabilized cables, ring cables, and the deflection of roof according to the height of the post or hub that affects the sag ratio of cable truss. The tensile forces of the cables and the deflection of the roof are compared for the cases when the retractable roof is closed and opened.

CLINICAL AND STATISTICAL STUDIES ON FIXED BRIDGE (가공의치의 임상 통계적 연구)

  • Kim, Seung-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.99-109
    • /
    • 1980
  • An investigation was made Into 1,357 fixed bridges which had been performed at the Department of Prosthetic Dentistry, Seoul National University Hospital from 1973 to 1979. The purpose of this investigation was to establish a basic reference of the treatment with fixed bridges by obtaining statistical conclusions from the data concerning the patients who had been treated with fixed bridges. The following conclusions were obtained; 1. The ratio of the fixed bridges made on the maxillae to those made on the mandible was 1:1. 2. The cases of fixed bridges with one pontic were the most frequent, i.e., 946 cases out of total 1,357 cases, which were 69.7% of the total. 3. As the number of missing teeth increased, the number of the relevant cases of fixed bridges decreased. 4. The most frequent age group of the patients who had been treated with fixed bridges was the twenties, which was 40.8% of the total. As the age of the patients increased, the number of corresponding cases of fixed bridges decreased. 5. Most of the fixed bridges with more than three pontics were made at the anterior portion samely on the maxilla and on the mandible. 6. As for the retainers, the porcelain fused to metal crown and the partial veneer crown were frequently used at the anterior portion, while the full veneer crown was frequently used and the inlay and the attachment were used in some cases at the posterior portion. The locations of fixed bridges in the order of their frequency were: canine, lateral incisor, second bicuspid, central incisor, second molar, first bicuspid, first molar, and third molar on the maxilla; second bicuspid, second molar, first bicuspid, first molar, canine, third molar, lateral incisor, and central incisor on the mandible.

  • PDF

Forming Characteristics of Outer Shell Structure for Thrust Chamber Nozzle Extension (연소기 노즐확장부 외피구조물의 성형 특성)

  • Ryu, Chul-Sung;Lee, Keum-Oh;Kim, Jong-Gyu;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.428-432
    • /
    • 2010
  • A study on the forming characteristics of outer shell structure for thrust chamber nozzle extension has been performed. In order to identify anisotropy of cold rolled sheet metal, three types of tensile specimens according to the direction to the sheet rolling axis were prepared and tested, and Landford's values were obtained using the results and applied to structural analysis. Forming characteristics of the outer shell structure of the nozzle extension are investigated through manufacturing and forming of the full scale outer shell structures, and strain values obtained by the forming processes are compared to the numerical analysis results. The results obtained by this study will be utilized to design forming tools and processes for manufacturing other outer shell structures which have a bigger expansion area ratio.

  • PDF

Regenerative Cooling Characteristics for Cooling Parameters of a Combustor in Liquid Rocket Combustors (재생냉각 연소기의 냉각기구에 따른 냉각 특성 파악)

  • Kim, Hong-Jip;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.145-149
    • /
    • 2010
  • Thermal analyses have been performed to study the effect of location of fuel ring and thermal barrier coatings in regenerative cooling channels in a full-scale combustor. For the effective cooling, the fuel ring has better be installed near axial location of the low expansion ratio and low heat flux, and branching of cooling channels is preferable. Also, the radiative cooled nozzle extension is thought to be reasonable for the cooling of combustion walls. Among the possible coatings, $Y_2O_3$ stabilized $ZrO_2$ coating and Ni/Cr coating have been adopted. Compared with Ni/Cr coating which has high oxidation resistance, $Y_2O_3$ stabilized $ZrO_2$ coating, one of ceramic coatings is found to be much effective to sustain the thermal survivability of combustion walls.

  • PDF

Standardization of composite connections for trapezoid web profiled steel sections

  • Saggaff, A.;Tahir, M.M.;Sulaiman, A.;Ngian, S.P.;Mirza, J.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.4
    • /
    • pp.765-784
    • /
    • 2015
  • Connections are usually designed either as pinned usually associated with simple construction or rigid normally is associated with continuous construction. However, the actual behaviour falls in between these two extreme cases. The use of partial strength or semi-rigid connections has been encouraged by Euro-code 3 and studies on semi-continuous construction have shown substantial savings in steel weight of the overall construction. Composite connections are proposed in this paper as partial or full strength connections. Standardized connection tables are developed based on checking on all possible failure modes as suggested by "component method" for beam-to-column composite connection on major axis. Four experimental tests were carried out to validate the proposed standardised connection table. The test results showed good agreement between experimental and theoretical values with the ratio in the range between 1.06 to 1.50. All tested specimens of the composite connections showed ductile type of failure with the formation of cracks occurred on concrete slab at maximum load. No failure occurred on the Trapezoidal Web Profiled Steel Section as beam and on the British Section as column.

A Study on Lighting Performance Evaluation of Light-Shelf using Crystal Face (결정면 적용 광선반 채광성능 평가 연구)

  • Lee, Heangwoo;Rogers, Kyle Eric;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.395-401
    • /
    • 2015
  • Recently, many research studies have been carried out on the efficiency of light-shelf daylighting systems, especially comparing performance improvements and the limitations of reflective surfaces and their lighting performance. In this study, a crystal face reflective surface is proposed. The objective of the study is to evaluate the lighting performance of a crystal face light-shelf through a performance study. The performance study was carried out in a full scale test-bed in order to calculate the light distribution and energy consumption utilizing the standard indoor illumination as an index. The conclusions of the performance study are as follows. 1) The optimal angle of incidence for daylighting for both the operable flat type light-shelf and the crystal face light-shelf are taken in the natural environment on the dates of the winter and summer solstices, as well as the autumn and spring equinoxes. 2) The application and installation of the crystal face light-shelf can produce a 29.9%~34.3% increase of light distribution within the indoor space. However, the increase of light distribution can also lead to a decrease in the uniformity ratio, a design challenge that should be considered when applying a crystal face light-shelf. 3) It is possible to achieve a 7.98%~13.3% greater reduction in energy consumption when applying a crystal face light-shelf than when applying a flat type light-shelf. The increase in the number of crystal faces should concur with the analysis of the energy reduction. A limitation of the study is that only one predetermined pattern was performance tested for a crystal face light-shelf. In order to carry out further research on crystal face light-shelves, additional performance studies are needed based on alternative patterns and designs.

Assessment of Optimum Reinforcement of Rebar for Joint of PHC Pile and Foundation Plate (고강도 콘크리트 말뚝과 기초판 접합부의 최적 철근보강량 산정)

  • Park, Jong-Bae;Sim, Young-Jong;Chun, Young-Soo;Park, Seong-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Method of protruding steel bar embedded in PHC pile for connecting with foundation plate is an intermediate form of fixed and hinged connection and has often been used in architectural structures such as apartment complex. However, mechanical properties of this method have not been proved and its construction process is not simple. In this study, therefore, by analyzing previous research and by considering ratio of steel bar and concrete in PHC pile, which is minimum reinforcement of rebar, the newly optimized method of reinforcing joint of PHC pile and foundation plate is suggested with respect to PHC pile type (PHC 450, PHC 500, and PHC 600). To assess mechanical properties (ultimate tensile and shear strength) of joint of PHC pile and foundation plate, full scale experimental tests are performed. As a result, all cases are satisfied with required design criteria and can be practically applied. Our results indicate that reduction of rebar reinforcement compared to previous method would lead cost saving in PHC pile construction.

Feasibility of Interference Alignment for Reverse Duplex in MIMO Cellular Networks with One-side Base Cooperation (다중 안테나를 사용하는 단방향 기지국 협력 역 듀플렉스 셀룰러 네트워크의 간섭 정렬 타당성)

  • Kim, Kiyeon;Jeon, Sang-Woon;Yang, Janghoon;Kim, Dong Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.273-284
    • /
    • 2015
  • The feasibility conditions of interference alignment (IA) are analyzed for reverse duplex systems, in which one cell operates as downlink (DL) while the other cell operates as uplink (UL) assuming one-sid base station (BS) cooperation. Under general multiple-input and multiple-output (MIMO) antenna configurations, a necessary condition and a sufficient condition for one-shot linear IA are established, i.e., linear IA without symbol or time extension. In several example networks, optimal sum degrees of freedom (DoF) is characterized by the derived necessary condition and sufficient condition. For some special class of networks, a sufficient condition is established in a more compact expression, which also yields the necessary and sufficient condition. Simulation results demonstrate that the proposed IA does not only achieve larger DoF but also significantly improves the sum rate in the practical signal-to-noise ratio (SNR) regime.

The Experimental Study on Removal of Sulfur Dioxide and Nitrogen Oxide Using a Nano-Pulse Corona Discharger at Different Temperatures (나노펄스 코로나 방전의 온도 변화에 따른 이산화황 및 일산화질소 제거에 관한 실험적 연구)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.4
    • /
    • pp.387-394
    • /
    • 2011
  • A study on the removal of sulfur dioxide and nitrogen oxide was carried out using a non-thermal nano-pulse corona discharger at different gas temperatures. Pulse voltage with a high voltage of 50 kV, a pulse rising time of about 100 ns, a full width at half maximum of about 500 ns and a frequency of 1 kHz was applied to a wire-cylinder corona reactor. Ammonia and propylene gases were added into the corona reactor as additives with a static mixer. Ammonia addition had less effect on $SO_2$ reduction at the higher temperature because of the retardation of ammonium sulfate formation. However, propylene addition enhanced NO reduction at higher temperature due to increased gas mixture. $SO_2$ was further removed at the mixed $SO_2$ and NO gas due to increased $NO_2$ by the conversion of NO. The addition of ammonia and propylene gases was more highly dominant for the removal of sulfur dioxide compared to the sole pulse corona without the additives. However, the specific energy density per unit concentration of pulse corona as well as propylene additive was an important factor to remove NO gas. Therefore, the specific energy density per unit concentration of 0.04 Wh/($m^3{\cdot}ppm$) was necessary for the NO removal of more than 80% with the concentration ratio of 2.0 for propylene and NO. Hydrogen peroxide was another alternative additive to remove both $SO_2$ and NO in the nano-pulse corona discharger.