고주파 공진형 방식 X-선 발생장치에 관한 연구 (A Study on High Frequency Resonant Type X-ray Generator)

  • 유동욱;하성운;백주원;김종수;김학성;원충연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.209-211
    • /
    • 1995
  • This paper is concerned with High Frequency, High Voltage Generator for X-ray using zero-voltage soft-switching PWM DC-DC high-power converter by Resonant method, which makes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series Resonant full-bridge PWM DC-DC high-power converter operating at a constant frequency;25kHz. The converter output regulation is digitally controlled using DSP (Digital Signal Processor) for obtaining a fast rising time and adjust output voltage within a wide load range.

  • PDF

볼트 접합 및 프리스트레스를 적용한 프리캐스트 콘크리트 보-기둥 외부접합부의 내진실험 (Seismic Experiment of Precast Concrete Exterior Beam-Column Joint Using Bolt Type Connection and Prestressing Method)

  • 이동주;이주동;오태수;강현구
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.125-133
    • /
    • 2014
  • 이 연구에서는 볼트접합 및 프리스트레스를 적용한 프리캐스트 콘크리트 보-기둥 외부접합부의 내진 및 구조적 성능을 평가하였다. 총 5개의 보-기둥 외부접합부 실험체를 제작하고 보 단부에 변위제어 방식으로 반복하중을 가하며 실험을 수행하였다. 이 연구의 결과를 근거로 다음과 같은 결론을 얻을 수 있었다. 완전 건식공법이 적용된 PC 접합부는 완전 습식공법이 적용된 RC 접합부보다 에너지소산이나 핀칭현상에 있어서 불리한 거동을 보였지만 이는 설계과정에서 의도된 현상이며, 횡변형 능력에 있어서는 우수한 결과를 보였다. 또한 층간변위비 4%까지 횡하중 저항성능의 손실이 발생하지 않았고 매설용너트에 항복이 집중되는 메커니즘을 보이는 점으로 미루어 볼 때 개발된 접합부는 외부접합부 횡저항시스템으로서 적합한 것으로 사료된다. 추가적인 프리스트레스는 PC 접합부의 과도한 핀칭현상 방지 및 접합부 균열제어에 효과적이었으며 PC 접합부의 전체적인 내진성능을 향상시켰다.

Full Bridge Resonant Inverter Using Asymmetrical Control with Resonant-frequency Tracking for Ultrasonic Cleaning Applications

  • Jittakort, Jirapong;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1150-1159
    • /
    • 2017
  • Flexibility in the power control of ultrasonic transducers has remained a challenge for cleaning applications. This paper introduces a modification of the existing piezoelectric ceramic transducer (PCT) circuit to increase the range of operation through its impedance characteristics. The output power is controlled using the asymmetrical voltage-cancellation (AVC) method. Together with a phase-locked loop control, the switching frequency of the inverter is automatically adjusted to maintain a lagging phase angle under load-parameter variations during the cleaning process. With the proposed modification, the region of the zero-voltage switching (ZVS) operation is extended, which results in a wider range of output power control. A hardware prototype is constructed and the control algorithm is implemented using an STM32F4 microcontroller. Simulation and experimental results are provided to verify the proposed method for a 50-W PCT. The operating frequency and output power ranges under study are 37 - 41 kHz and 15.8 - 50 W, respectively.

ZVS Operating Range Extension Method for High-Efficient High Frequency Linked ZVS-PWM DC-DC Power Converter

  • Sato S.;Moisseev S.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.227-230
    • /
    • 2003
  • In this paper, a full bridge edge-resonant zero voltage mode based soft-switching PWM DC-DC power converter with a high frequency center tapped transformer link stage is presented from a practical point of view. The power MOSFETS operating as synchronous rectifier devices are implemented in the rectifier center tapped stage to reduce conduction power losses and also to extend the transformer primary side power MOSFETS ZVS commutation area from the rated to zero-load without a requirement of a magnetizing current. The steady-state operation of this phase-shift PWM controlled power converter is described in comparison with a conventional ZVS phase-shift PWM DC-DC converter using the diodes rectifier. Moreover, the experimental results of the switching power losses analysis are evaluated and discussed in this paper. The practical effectiveness of the ZVS phase-shift PWM DC-DC power converter treated here is actually proved by using 2.5kW-32kHz breadboard circuit. An actual efficiency of this converter is estimated in experiment and is achieved as 97$\%$ at maximum.

  • PDF

고감도 단상력률계의 설계 및 시작 (Design and Implementation of High Sensitivity Single Power Factor Meter.)

  • 박정후
    • 수산해양기술연구
    • /
    • 제15권2호
    • /
    • pp.55-60
    • /
    • 1979
  • 본 실험장치에 관한 이상의 이론과 실험을 통해 다음과 같은 결론을 얻을 수 있다. 1. 연산기로써 전류입력파형을 부경전류의 다소에 관계없이 일정진폭의 단형파로 변화시킴으로써 부경전류 0.01[A] 이상의 역율의 정밀측정이 가능하다. 2. 영구자석가동코일형 직류전류계를 사용하여 출력파형의 평균치들 얻음으로써 역율값을 0-1의 전절원에 걸쳐 평균 눈금으로 직독할 수 있다. 3. Fig. 19에서 알 수 있듯이 진력율이나 지력율에 관계없이 측정가능하며 모두 정의 눈금으로 읽을 수 있다. 4. 출력저항에서 역률 Relay 회로를 쉽게 도입할 수 있어 전기기계의 자동제어, 보호, 경보 등의 회로를 쉽게 적용할 수 있다.

  • PDF

단상유도전동기의 돌입전류저감을 위한 제어기 설계 (Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor)

  • 박수강;백형래;이상일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권5호
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

적층식 대형창고 스프링클러헤드 개발 및 성능실험 (A Development and Performance Experiment on In-rack Sprinkler Head for Rack Type Warehouse)

  • 김운형;이준;홍성호;김종훈;양소진
    • 한국재난정보학회 논문집
    • /
    • 제15권2호
    • /
    • pp.214-222
    • /
    • 2019
  • 연구목적: 적층형 물류창고의 랙크 내에 설치하여 화세제어 및 초기 진압이 가능한 스프링클러 헤드를 개발하고 이에 따른 성능확인 실험을 목적으로 한다. 연구방법: 살수반경과 살수패턴을 고려하여 여러가지 디플렉터를 설계하고 살수각도 및 방사 시험 및 방호성능 실험을 수행하였으며 결과를 비교 분석하였다. 연구결과: 적재물 전체 및 전면부 방호가 가능하고 최소방수량 115L/min을 가지는 최적의 헤드를 개발하였다. 결론: 개발된 헤드는 방수량 K-115, 방수압 1Bar 조건에서 1단 소화실험 결과, 적용된 화재시나리오에서 적재물품을 전부 연소시키지 않고 화재를 제어함을 확인하였다. 아울러 적재물 상단에서 디플렉터까지의 수직거리는 450mm 이격하여 가연물 외곽부분으로도 충분히 방사되도록 설치해야 한다.

AVR의 응답속도개선을 위한 제어기법에 관한 연구 (Control techniques for improving response of the AVR)

  • 이형기;김송현;김현수;김기량;김관형
    • 한국정보통신학회논문지
    • /
    • 제19권11호
    • /
    • pp.2534-2539
    • /
    • 2015
  • 발전기의 전압조정장치(AVR)를 이용하여 전압을 조절하는 방식은 기존 아날로그방식과 교체중인 디지털방식을 나눌 수 있다. 일반적으로 브러쉬레스형의 여자시스템을 이용하여 전압을 조절할 경우 전부하에 대하여 전압변동을 작게 하여야 한다. AVR의 제어방법으로 PID(비례-적분-미분)제어방식이 많이 사용되고 있다. 그러나 이 제어기법은 제어대상에 대하여 제어기의 파라미터를 조절하여 과도응답을 줄이고 있다. 따라서 제어대상이 달라질 경우 다시 제어기의 파라미터를 다시 설정해야하는 문제점이 있다. 본 연구에서는 제어대상의 파라미터 변동에 대하여 제어기의 파라미터를 재설정 필요없이 iPID(intelligent PID)제어기를 이용하여 발전기 AVR시스템에 적용하여 전부하 시에도 전압변동이 작은 응답을 얻도록 설계하고 시뮬레이션과 실험을 통하여 과도응답을 개선하였다.

비접촉 동력 전달을 위한 마그네트 기어 기반 감속기의 속도 제어에 관한 연구 (Speed Control Of The Magnet Gear-Based Speed Reducer For Non-contact Power Transmission)

  • 정광석
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.380-388
    • /
    • 2016
  • 마그네트 기어를 이용하면 기계적인 접촉없이 동력을 전달할 수 있다. 마그네트 기어 기반 감속 시스템에서 종동축은 구동축으로부터 분리되어있기 때문에 시스템은 제한된 공극 강성으로 부하 변화에 대응해야하는 2관성 공진 시스템이다. 종동축 즉, 저속측은 구동축 인가 토크만으로 제어되고 갑작스런 외란에 따라 일반적인 기계식 기어 시스템과 달리 과도한 진동이나 슬립이 발생할 수 있다. 따라서 저속측에 인가되는 부하 등의 외란은 실시간으로 측정되거나 추정되어야 한다. 본 논문에서는 고조파 조절기 일체형 마그네트 기어를 이용한 감속 시스템의 저속측 속도 제어를 위한 전상태 되먹임 제어기를 제안하고 이를 전산 모의 시험과 실험을 통해 검증하였다. 저속측 부하를 추정하기 위해 새로운 상태변수를 도입하여 관측기를 설계하였으며 이를 기반으로 하는 전상태 제어기를 통한 외란에 대한 강건성은 2자유도 PI 속도 제어기와 비교하였다. 상대적으로 짧은 시간안에 극의 슬립이 보정되는 것을 확인하였으며 추정된 변수는 실제 측정 결과와 유사한 경향을 나타내었다. 이러한 결과는 마그네트 기어 감속기의 서보 시스템으로의 응용 가능성을 담보해주는 결과인 것으로 판단된다.

분절형 복부 중공 프리스트레스트 콘크리트 교량 거더의 설계 및 실물크기 휨 실험 분석 (Design and Full Size Flexural Test of Spliced I-type Prestressed Concrete Bridge Girders Having Holes in the Web)

  • 한만엽;최석환;전용식
    • 대한토목학회논문집
    • /
    • 제31권3A호
    • /
    • pp.235-249
    • /
    • 2011
  • I형 PSC 거더에 새로운 설계 개념을 도입하여 낮은 형고의 장경간 거더를 설계하고, 실험을 통해서 적용성을 점검하였다. 본 연구에서 제안하는 거더는 복부에 개구부를 도입한 분절형 중공 프리캐스트 프리스트레스트 콘크리트 거더(HWPC거더, Holed Web Prestressed Concrete girders)이다. 이 거더의 설계에는 세 가지 설계 개념이 종합적으로 적용되었다. 먼저 장경간의 거더를 공장에서 프리캐스트로 타설하여 양생을 마친 후에 현장으로 운반하는 방법을 채택하여 현장에서 거더를 제작하는 경우보다 콘크리트의 품질 관리가 용이하게 하여 고강도 및 고성능 콘크리트를 적용하는 것이 가능하게 하였다. 또한 거더를 분절화하여 제작하여 국내의 도로 여건에서도 장경간 거더를 공장에서 현장으로 이동시킬 수 있게 하였다. 이로써 현장에서의 작업 기간도 단축시킬 수 있다. 두 번째로 거더의 복부에 원형의 개구부를 도입하여, 단부 정착장치의 반을 이 개구부 내에 이동하여 분산 배치하여, 분절 거더의 조립에 사용하였다. 개구부에 정착부를 분산 배치하면 단부에 설치되는 정착장치가 줄어들게 되므로 단부에 작용하는 응력이 줄어들게 된다. 아울러 자연스레 단부에 도입되는 휨모멘트는 줄어들고, 중앙부에 큰 휨모멘트가 도입되므로 외력으로 인한 휨모멘트 분포에 더 가까운 형상의 부모멘트를 거더에 도입할 수 있다. 거더에 개구부를 도입하면 거더 자중도 줄어든다. 그리고, 세째로 단부에 설치되는 정착구의 수가 줄기 때문에 단부에서는 다이아프램을 제거하고도 정착이 가능하다. 이렇게 거더의 전 단면에 걸쳐서 같은 폭의 복부폭을 사용하면 거더 제작을 자동화 하는데도 도움이 될 것이다. HWPC거더의 설계 기법을 검증하고, 다단계 긴장의 효과 및 실제교량에 적용할 때 발생할 수 있는 문제점을 고찰하기 위하여 실물 실험을 수행하였다. 길이 50 m, 높이 2 m인 거더 실험체를 분절형과 일체형으로 각각 1개씩 제작하여 휨실험을 수행하고, 결과를 비교하여 분석하였다. 분절형 거더와 일체형 거더는 처짐 및 균열생성 형상에서 근본적으로 유사하였다. 휨 강도, 처짐, 활하중 처짐제한 규정 등이 특정 설계기준을 만족하도록 설계하는 것이 가능하였다.