• 제목/요약/키워드: fuel distribution

Search Result 1,404, Processing Time 0.033 seconds

A Study of the Combustion Flow Characteristics of a Exhaust Gas Recirculation Burner with Both Outlets Opening (양쪽 출구가 트인 배기가스 재순환 버너의 연소 유동 특성에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.696-701
    • /
    • 2018
  • The nitrogen oxides generated during combustion reactions have a great influence on the generation of acid rain and fine dust. As an NOx reduction method, exhaust gas recirculation combustion using Coanda nozzles capable of recirculating a large amount of exhaust gas with a small amount of air has recently been utilized. In this study, for the burner outlet with dual end opening, the use of a recirculation burner was investigated for the distribution of the pressure, streamline, temperature, combustion reaction rate and nitrogen oxides using computational fluid analysis. The gas mixed with the combustion air and the recirculated exhaust gas flow in the tangential direction of the circular cylinder burner, so that there is a region with low pressure in the vicinity of the fuel nozzle exit. As a result, a reverse flow is formed in the central portion of the burner near the center of the circular cylinder burner and the exhaust gas is discharged to the outside region of the circular cylinder burner. The combustion reaction occurs on the right side of the burner and the temperature and NOx distribution are relatively higher than those on the left side of the burner. It was found that the average NOx production decreased from an air flow ratio of 1.0 to 1.5. When the air flow ratio is 1.8, the NOx production increases abruptly. It is considered that the NOx production reaction increases exponentially with temperature when the air ratio is more than 1.5 and the NOx production reaction rate increases rapidly on the right-hand side of the burner.

Study on Methanol Conversion Efficiency of Steam-Methanol Reforming on Pipe Shape and Flow Rate Variation in Curved Channel (수증기-메탄올 개질기의 곡유로 채널형 관 형태 변화에 따른 메탄올 전환율 및 유동 특성에 관한 수치해석적 연구)

  • Seong, Hong Seok;Lee, Chung Ho;Suh, Jeong Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.173-179
    • /
    • 2016
  • This is a numerical study on the curved channel type of hydrogen reformer using the commercial code of fluid dynamics. We numerically compared the numerical model in a previous study model and the modelling of a tube type curved channel. In the result of numerical analysis on 4 types of curved channel reformers, the methanol conversion efficiency of type 1~4 were 45.0%, 45.3%, 45.6%, 45.6% respectively, and there was hardly any difference by ${\pm}0.6%$. In light of flow characteristics, the rectangle type tube and the type 2 with $45^{\circ}$ turn showed most uniform flow characteristics and concentration distribution of methanol, and the circular type tube and the type 3 with $90^{\circ}$ turn had most un-uniform flow characteristics and concentration distribution of methanol. We concluded that the design for curved channel reformer has to have rectangle type tube with curve of almost $45^{\circ}$ as in the type of curved pipe with $45^{\circ}$ turn.

Numerical Study on the Cooling Characteristics of a Passive-Type PEMFC Stack (수동공기공급형 고분자 전해질 연료전지 스택에서의 냉각특성에 대한 전산해석 연구)

  • Lee, Jae-Hyuk;Kim, Bo-Sung;Lee, Yong-Taek;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.767-774
    • /
    • 2010
  • In a passive-type PEMFC stack, axial fans operate to supply both oxidant and coolant to cathode side of the stack. It is possible to make a simple system because the passive-type PEMFC stack does not require additional cooling equipment. However, the performance of a cooling system in which water is used as a coolant is better than that of the air-cooling system. To ensure system reliability, it is essential to make cooling system effective by adopting an optimal stack design. In this study, a numerical investigation has been carried out to identify an optimum cooling strategy. Various channel configurations were applied to the test section. The passive-type PEMFC was tested by varying airflow rate distribution at the cathode side and external heat transfer coefficient of the stack. The best cooling performance was achieved when a channel with thick ribs was used, and the overheating at the center of the stack was reduced when a case in which airflow was concentrated at the middle of the stack was used.

Comparative Analysis on Efficiency and Productivity for Korea, Japan and Global Parcel Delivery Companies (한국, 일본, 글로벌 택배기업의 효율성 및 생산성 비교 분석)

  • Ma, Jin-Hee;Ahn, Young-Hyo
    • Journal of Distribution Science
    • /
    • v.14 no.3
    • /
    • pp.73-83
    • /
    • 2016
  • Purpose - The parcel delivery service(courier) industry all over the world has been expanding its market so far, but its growth has been declining in recent years. In this situation, most parcel delivery companies are having trouble with managing themselves because of the pressure from the customer to increase service level and decrease the rate. The purpose of this study is to provide ways to improve competitive advantages of the parcel delivery service industry by evaluating the multi-period operating efficiency of Korea, Japan and global service providers. Research design, data, and methodology - The data for the period of 2011 to 2014 were collected from the annual reports published by parcel delivery companies. In this study, we analyze the marketability (revenue), profitability (operating profits), and management conditions (net profits) of parcel service companies by combining information on human resources (number of employees) and material resources (total assets and equity). Therefore, the number of employees, total assets, and equity are selected as input variables, and revenue, operating profits, and net profits as the output variables. In this study, DEA (Data Envelopment Analysis) is used to measure the comparative efficiency and MPI (Malmquist Productivity Index) is used to analyze the trend of change of the efficiency for a multi-year period. Results - The operational efficiency scores of medium-sized parcel delivery companies in Korea are higher than other larger competitors such as Korean, Japan and Global larger companies. As of 2014, Logen(1.878) was found to be the most efficient parcel delivery enterprise, followed by KGB (1.224), and Kyoungdong(1.002). Otherwise, Hanjin(0.235), CJ(0.262), Hyundai Logistics(0.657), DHL(0.611), UPS(0.766), FedEx(0.498), TNT(0.350), Yamato(0.762) and Sagawa(0.520), larger sized companies, were done inefficiently. The productivity of parcel delivery companies is influenced by endogenous factors as well as exogenous ones such as changes in business environment and technological advances. Conclusions - Korean medium-sized companies have relatively high efficiency scores in operation. That is why they still survive the competitive market in Korea where market restructuring on the industry has been expected to be conducted for many years. The reason why medium-sized couriers had higher efficient scores than larger couriers is that most of couriers spend more operating expenses versus unit price of delivery which is the amount of money that is needed in order to send a package by parcel service. So the delivery unit price must be taken into account by all the expenses associated with the cost of fuel, labor and maintenance expenses for facilities, etc. therefore, the unit price must be increased to strengthen business competitive power. In order for the industry to have more competitive advantage, the companies need to make profits by increasing demand volume and raising the delivery rate to provide high-quality delivery service to customers. And both endogenous and exogenous change must take precedence in order to strengthen their competitiveness.

Evaluation of Neutron Flux Distributions of SMART-P IST Region for the Design of Ex-Core Detector (SMART 연구로 노외계측기 설계를 위한 IST 영역의 중성자속 분포 평가)

  • Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • The evaluation of neutron flux distribution was performed for the ex-core detector design of SMART-P. DORT and MCNP code were used for the calculation of energy-dependent neutron flux distribution at 100% full power condition. Two code results show that maximum thermal flux appears at the $1^{st}$ water region in IST region and agree within 10% difference. In addition, another evaluation was performed code with assumptions that cote was composed of fission source and control rod without fuel assemblies. These assumptions make neutron count rate to be minimized. As a results, maximum thermal flux showed $6.99{\times}10^{-2}(n/cm^2-sec)$, when the strength of initial fission source was assumed as $1.0{\times}10^8(n/sec)$. The main reason of these results is due to the thermalization of fast neutrons in the water region and thermal flux is proportional to 80% of total neutron flux. Therefore, optimization of filler material of detector guide tube, position of installation and axial length of detector segments is necessary for the design of ex-core detector to enhance the neutron count rate and above results could be used in ex-core detector design as a fluence requirement.

Simulation of Plume Length Induced by Orimulsion Combustion (오리멀젼 연소시 발생하는 백연의 연기거리 전산모사)

  • Kwak, Byoung-Kyu;Kim, Jong-Ho;Joo, Ji-Bong;Lee, Jeong-Jin;Kim, Jin-Soo;Kim, Young-Hun;Yi, Jong-Heop
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.136-143
    • /
    • 2008
  • The objective of this study is to investigate the visibility of plume at the Y power plant stack, which fires the orimulsion as a fuel. The plume contains numerous primary particles under $1\;{\mu}m$ size and inorganic ions possibly inferred by the chemicals of secondary aerosol formation. We evaluated the visibility of the plume using the modified PLUVUE-II model. The monitoring data on the particle size distribution (PSD) and secondary aerosols of sulfate were applied to estimate and evaluate the main factors of plume opacity. The chemical reactions were applied to the model for the secondary aerosol formation of $(NH_4)_2SO_4(s)$. The maximum plume length was estimated by an optic method using threshold contrast. The results showed that the plume length was strongly dependent upon the PSD and $(NH_4)_2SO_4(s)$ concentration of the plume emitted from the stack.

  • PDF

An Analysis of Economic Evaluation Related to Lane Departure Warning System (주행로이탈예방지원기술 관련 경제성평가 분석)

  • Ryu, Byung-Yong;Choi, Ji-Eun;Bae, Sang-Hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.85-97
    • /
    • 2009
  • Continuous increase of traffic demand has caused confirmed congestion, fuel consumption, emission, safety, etc. as serious social problems at the present time. The Smart Highway Project has been conducted by the supervision of Ministry of Land, Transport and Maritime Affaire to solve such problems since 2007. The Smart Highway Project includes LDWS (Lane Departure Warning System), a system to prevent broadside collisions and accidents, as a sub-technology of road-vehicle associating technologies. This system warns drivers when their vehicle deviates from the lane where they are traveling at high-speed on the highway. In this paper, the LDWS was evaluated using CBA to analyze the socio-economic consequences. Estimated benefits include reduction of accidents and convenience of drivers. In addition, the economics according to the distribution rate is various when it comes to Lane Departure Warning Technology, the economics of both cases - positive scenario and negative scenario, which was analyzed. As a result, the Benefit-Cost ratio(B/C) of negative scenario showed 0.97 in 2020 and 1.36 in 2030 while B/C ratio of the positive scenario showed 1.04 in 2020 and 1.59 in 2030, which indicated that the higher distribution rate is, the higher the economics generates. Therefore, it is judged that the introduction of Lane Departure Warning Technology will result in high economics.

  • PDF

Estimation of Benzene Emissions from Mobile Sources in Korea (국내 이동오염원에서 발생되는 벤젠 배출량 산정)

  • Lee, Ju-Hyoung;Cha, Jun-Seok;Hong, Ji-Hyung;Jung, Dong-Il;Kim, Ji-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.72-82
    • /
    • 2008
  • Benzene is a very harmful and toxic compound known as human carcinogen by all routes of exposure. Owing to the risky feature of benzene, several countries such as Japan, UK and EU have established the ambient air quality standard and protect from that risk of it. Korea also has designated it as one of the criteria air pollutants and established the concentration limit ($5\;{\mu}g/m^3$) in the air and is going to apply the standard from 2010. Benzene is emitted from various sources such as combustion plants, production processes, waste treatment facilities and also automobiles. Mobile source is known as one of the major emission sources of benzene. In this study, we estimated the domestic emissions of benzene from mobile source and compared the results with those of advanced countries. Mobile source was divided into 2 categories, Le., on-road source and non-road source. The total emissions of benzene from mobile source were estimated as 3,106 tons/yr and 1,612 tons/yr was emitted from on-road source and 1,494 tons/yr was from non-road source. Emission ratio of benzene from on-road source showed that 80.0% was from passenger cars, 10.1% was from taxis, 7.2% was from light-duty vehicles, 2.5% was from heavy-duty vehicles and 0.2% was from buses. In the case of non-road source, the distribution showed that 66.3% was from construction machineries, 14.5% was from locomotives, 11.7% was from ships, 7.1% was from agriculture equipments and 0.5% was from aircrafts. The cold-start emissions were estimated as 942 tons/yr and this value was almost 1.5 times greater than that for hot engine emissions (608 tons/yr). In addition, the fuel-based distribution was 65.9%, 31.1% and 2.8% from gasoline, LPG and diesel vehicles, respectively. The emission ratio from mobile source occupied 65% and 30% of total benzene emissions in USA and UK, respectively. In case of Korea, the emission ratio of benzene from mobile source occupied 29% (15% from on-road source, 14% from non-road source) which showed similar value with UK.

Experimental Study on the Heating Performances of the Air Heater with Diesel for Passenger Cabin Heating of an Electric Vehicle (전기자동차용 승차공간 난방용 디젤 공기 히터의 실차 성능에 관한 연구)

  • Bang, You-Ma;Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7250-7255
    • /
    • 2015
  • The objective of this study is to experimentally investigate the heating performances of the portable air combustion heater using diesel fuel for auxiliary cabin heating of the battery electric vehicle. In order to evaluate the heating performances of the air combustion heater, the heating capacity was calculated by the temperature at inlet and outlet parts of the considered heater and the inner temperature distribution characteristics of the vehicle were measured during 1600 seconds with an interval of 1 second. The theoretical efficiency of the tested heater was calculated by temperature data of the air of supplying and exhausting to the cabin. As the air passed the heat-sink, the air temperature at the end of heat-sink reached to $101.3^{\circ}C$ and the difference of temperature on heat-sink was 67.8%. The average heating capacity of the air combustion heater showed 2.0 kW. After 1800 seconds, the inner temperature of the vehicle cabin was continuously increased. The temperatures of the top side and the bottom side of the car cabin under consideration were increased upto $42.5^{\circ}C$ and $24.3^{\circ}C$, respectively, and the theoretical efficiency of the tested heater was on average 63.7%.

Temporal and Spatial Distribution of Ambient Sulfur Dioxide Concentration in Forest Areas, Korea (우리나라 산림지역에서의 이산화황 농도의 시.공간적 분포)

  • Seung-Woo, Lee;Lee, Choong-Hwa;Ji, Dong-Hun;Youn, Hee-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.1035-1039
    • /
    • 2010
  • For 65 national forest areas in 1993 to 2008, the ambient sulfur dioxide ($SO_2$) concentrations were measured monthly using passive samplers and compared to the those of urban areas in order to investigate the characteristics of temporal and spatial distribution. In the forest areas, annual average concentration of sulfur dioxide gradually decreased from the beginning year of monitoring to 1997 and then had no significant change, such as the annual trend in urban areas monitored by Ministry of Environment. For the monitoring term, average concentration of sulfur dioxide in the forest areas was 5.6ppb, which was lower than the 10.1ppb in the urban areas and the EC ecological standard level (7.6 ppb). Seasonally, both in forest areas and urban areas the monthly average concentrations were much higher in winter and spring due to much more heating fuel consumption, and lowest in summer. Regional comparison to other regions of Gyeongbuk and Gyeonggi province showed that the concentration of sulfur dioxide was the highest during year. A significant positive correlation between sulfur oxides' emissions and sulfur dioxide concentration by province was observed, reflecting that the size and proximity of sources of atmospheric sulfur oxides could be important factors in determination.