• 제목/요약/키워드: friction damper (FD)

검색결과 3건 처리시간 0.023초

Evaluation of performance of eccentric braced frame with friction damper

  • Vaseghi Amiri, J.;Navayinia, B.;Navaei, S.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.717-732
    • /
    • 2011
  • Nonlinear dynamic analysis and evaluation of eccentric braced steel frames (EBF) equipped with friction damper (FD) is studied in this research. Previous studies about assessment of seismic performance of steel braced frame with FD have been generally limited to installing this device in confluence of cross in concentrically braced frame such chevron and x-bracing. Investigation is carried out with three types of steel frames namely 5, 10 and 15 storeys, representing the short, medium and high structures respectively in series of nonlinear dynamic analysis and 10 slip force values subjected to three different earthquake records. The proper place of FD, rather than providing them at all level is also studied in 15 storey frame. Four dimensionless indices namely roof displacement, base shear, dissipated energy and relative performance index (RPI) are determined in about 100 nonlinear dynamic analyses. Then average values of maximum roof displacement, base shear, energy dissipated and storey drift under three records for both EBF and EBF equipped with friction damper are obtained. The result indicates that FD reduces the response compared to EBF and is more efficient than EBF for taller storey frames.

마찰댐퍼에 의한 사장 케이블의 진동저감 효과 (Vibration Reduction Effects of Stay Cable Due to Friction Damper)

  • 김형구;임성순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.54-61
    • /
    • 2013
  • 사장교 케이블은 초기 큰 인장력으로 축강성이 매우 크지만, 횡방향 휨강성은 약하다. 풍하중이나 교통하중은 케이블을 심각하게 진동시켜 사장교의 사용성에 부정적 영향을 끼친다. 그러므로 장대교량에 감쇠장치를 설치하는 진동 저감 계획이 절실히 요구된다. 마찰댐퍼는 교통하중이나 풍하중과 같은 동적하중이 작용하는 케이블 진동에서 진폭과 지속시간을 대폭 감소시킬 수 있는 효과적인 장치임을 알 수 있다. 케이블 진동은 댐퍼제작방법과 설치위치 및 형상에 따라 효율이 달라질 수 있다. 그럼에도 불구하고 본 실험연구의 마찰댐퍼 설치전 후 제진성능효과 분석결과는 향후 사장케이블의 진동을 저감시키는 기본 자료로 활용할 수 있다.

Enhancing the Seismic Performance of Multi-storey Buildings with a Modular Tied Braced Frame System with Added Energy Dissipating Devices

  • Tremblay, R.;Chen, L.;Tirca, L.
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.21-33
    • /
    • 2014
  • The tied braced frame (TBF) system was developed to achieve uniform seismic inelastic demand along the height of multi-storey eccentrically braced steel frames. A modular tied braced frame (M-TBF) configuration has been recently proposed to reach the same objective while reducing the large axial force demand imposed on the vertical tie members connecting the link beams together in TBFs. M-TBFs may however experience variations in storey drifts at levels where the ties have been removed to form the modules. In this paper, the possibility of reducing the discontinuity in displacement response of a 16-storey M-TBF structure by introducing energy dissipating (ED) devices between the modules is examined. Two M-TBF configurations are investigated: an M-TBF with two 8-storey modules and an M-TBF with four 4-storey modules. Three types of ED devices are studied: friction dampers (FD), buckling restrained bracing (BRB) members and self-centering energy dissipative (SCED) members. The ED devices were sized such that no additional force demand was imposed on the discontinuous tie members. Nonlinear response history analysis showed that all three ED systems can be used to reduce discontinuities in storey drifts of M-TBFs. The BRB members experienced the smallest peak deformations whereas minimum residual deformations were obtained with the SCED devices.